{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,3,25]],"date-time":"2025-03-25T18:47:31Z","timestamp":1742928451231,"version":"3.40.3"},"publisher-location":"Cham","reference-count":12,"publisher":"Springer International Publishing","isbn-type":[{"type":"print","value":"9783030151263"},{"type":"electronic","value":"9783030151270"}],"license":[{"start":{"date-parts":[[2019,1,1]],"date-time":"2019-01-01T00:00:00Z","timestamp":1546300800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019]]},"DOI":"10.1007\/978-3-030-15127-0_57","type":"book-chapter","created":{"date-parts":[[2019,3,21]],"date-time":"2019-03-21T04:17:42Z","timestamp":1553141862000},"page":"571-579","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Study on Double Piezoelectric Layers Driven Pump Based on MEMS and 3D Printing"],"prefix":"10.1007","author":[{"given":"Liang","family":"Huang","sequence":"first","affiliation":[]},{"given":"Gang","family":"Tang","sequence":"additional","affiliation":[]},{"given":"Min","family":"Hu","sequence":"additional","affiliation":[]},{"given":"Zhibiao","family":"Li","sequence":"additional","affiliation":[]},{"given":"Xiaoxiao","family":"Yan","sequence":"additional","affiliation":[]},{"given":"Bin","family":"Xu","sequence":"additional","affiliation":[]},{"given":"Xiaozhen","family":"Deng","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2019,3,22]]},"reference":[{"issue":"10","key":"57_CR1","doi-asserted-by":"publisher","first-page":"1276","DOI":"10.1177\/1045389X13504476","volume":"25","author":"J Valdovinos","year":"2014","unstructured":"Valdovinos, J., Williams, R.J., Levi, D.S., et al.: Evaluating piezoelectric hydraulic pumps as drivers for pulsatile pediatric ventricular assist devices. J. Intell. Mater. Syst. Struct. 25(10), 1276\u20131285 (2014)","journal-title":"J. Intell. Mater. Syst. Struct."},{"key":"57_CR2","unstructured":"Zhang, Z., Wang, W., Chen, X.: Study on the performance of piezoelectric micro pump for insulin injection. Chin. J. Med. Instrum. 39(1), 64\u201367 (2015)"},{"key":"57_CR3","unstructured":"Research on water cooling system of computer chip whose power source is pressure electric pump. Jilin university (2005)"},{"issue":"1","key":"57_CR4","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1016\/S0925-4005(04)00108-X","volume":"105","author":"A Ludwigs","year":"2005","unstructured":"Ludwigs, A.: Micropumps-past, progress and future prospects. Sens. Actuators 105(1), 28\u201338 (2005)","journal-title":"Sens. Actuators"},{"key":"57_CR5","doi-asserted-by":"crossref","unstructured":"Liu, J., Sun, X., Liu, G., et al.: Experiment on dual-chamber parallel piezoelectric stack pump for electrorheological fluids. In: International Conference on Mechatronics and Automation. IEEE (2011)","DOI":"10.1109\/ICMA.2011.5985771"},{"issue":"2","key":"57_CR6","doi-asserted-by":"publisher","first-page":"445","DOI":"10.1016\/j.sna.2005.10.018","volume":"130","author":"A Doll","year":"2006","unstructured":"Doll, A., Heinrichs, M., Goldschmidtboeing, F., et al.: A high performance bidirectional micropump for a novel artificial sphincter system. Sens. Actuators, A 130(2), 445\u2013453 (2006)","journal-title":"Sens. Actuators, A"},{"issue":"3","key":"57_CR7","first-page":"30","volume":"30","author":"T Peng","year":"2009","unstructured":"Peng, T.: Investigation on piezo-pump used in water-cooling-system for computer CPU Chip. J. Refrig. 30(3), 30\u201334 (2009)","journal-title":"J. Refrig."},{"key":"57_CR8","unstructured":"Shou, L., Yao, L.Q., Wang, Y.H., et al.: A kind of concentric piezoelectric membrane micropump for medical use. Piezoelectrics Acoustooptics 6, 021 (2005)"},{"issue":"2","key":"57_CR9","doi-asserted-by":"publisher","first-page":"119","DOI":"10.1016\/j.mee.2003.10.005","volume":"71","author":"JH Kim","year":"2004","unstructured":"Kim, J.H., Kang, C.J., Kim, Y.S.: A disposable polydimethylsiloxane-based diffuser micropump actuated by piezoelectric-disc. Microelectron. Eng. 71(2), 119\u2013124 (2004)","journal-title":"Microelectron. Eng."},{"issue":"1","key":"57_CR10","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1016\/S0924-4247(98)00058-2","volume":"69","author":"A Ullmann","year":"1998","unstructured":"Ullmann, A.: The piezoelectric valve-less pump - performance enhancement analysis. Sens. Actuators, A 69(1), 97\u2013105 (1998)","journal-title":"Sens. Actuators, A"},{"issue":"6","key":"57_CR11","doi-asserted-by":"publisher","first-page":"1280","DOI":"10.1007\/s11664-011-1848-x","volume":"41","author":"NV Nong","year":"2012","unstructured":"Nong, N.V., Samson, A.J., Pryds, N., et al.: Microstructure and thermoelectric properties of screen-printed thick films of misfit-layered cobalt oxides with Ag addition. J. Electron. Mater. 41(6), 1280\u20131285 (2012)","journal-title":"J. Electron. Mater."},{"key":"57_CR12","doi-asserted-by":"publisher","first-page":"38798","DOI":"10.1038\/srep38798","volume":"6","author":"G Tang","year":"2016","unstructured":"Tang, G., Yang, B., Hou, C., Liu, J., et al.: A piezoelectric micro generator worked at low frequency and high acceleration based on PZT and phosphor bronze bonding. Sci. Rep. 6, 38798 (2016)","journal-title":"Sci. Rep."}],"container-title":["Lecture Notes in Computer Science","Human Centered Computing"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-030-15127-0_57","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,20]],"date-time":"2019-05-20T08:33:14Z","timestamp":1558341194000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-030-15127-0_57"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019]]},"ISBN":["9783030151263","9783030151270"],"references-count":12,"URL":"https:\/\/doi.org\/10.1007\/978-3-030-15127-0_57","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"type":"print","value":"0302-9743"},{"type":"electronic","value":"1611-3349"}],"subject":[],"published":{"date-parts":[[2019]]},"assertion":[{"value":"22 March 2019","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}},{"value":"HCC","order":1,"name":"conference_acronym","label":"Conference Acronym","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"International Conference on Human Centered Computing","order":2,"name":"conference_name","label":"Conference Name","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Merida","order":3,"name":"conference_city","label":"Conference City","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Mexico","order":4,"name":"conference_country","label":"Conference Country","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2018","order":5,"name":"conference_year","label":"Conference Year","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"5 December 2018","order":7,"name":"conference_start_date","label":"Conference Start Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"7 December 2018","order":8,"name":"conference_end_date","label":"Conference End Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"4","order":9,"name":"conference_number","label":"Conference Number","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"icpca2018","order":10,"name":"conference_id","label":"Conference ID","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"http:\/\/hcc.scholat.com\/","order":11,"name":"conference_url","label":"Conference URL","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Open","order":1,"name":"type","label":"Type","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information"}},{"value":"other","order":2,"name":"conference_management_system","label":"Conference Management System","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information"}},{"value":"146","order":3,"name":"number_of_submissions_sent_for_review","label":"Number of Submissions Sent for Review","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information"}},{"value":"50","order":4,"name":"number_of_full_papers_accepted","label":"Number of Full Papers Accepted","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information"}},{"value":"18","order":5,"name":"number_of_short_papers_accepted","label":"Number of Short Papers Accepted","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information"}},{"value":"34% - The value is computed by the equation \"Number of Full Papers Accepted \/ Number of Submissions Sent for Review * 100\" and then rounded to a whole number.","order":6,"name":"acceptance_rate_of_full_papers","label":"Acceptance Rate of Full Papers","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information"}},{"value":"2-3","order":7,"name":"average_number_of_reviews_per_paper","label":"Average Number of Reviews per Paper","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information"}},{"value":"4,3","order":8,"name":"average_number_of_papers_per_reviewer","label":"Average Number of Papers per Reviewer","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information"}},{"value":"Yes","order":9,"name":"external_reviewers_involved","label":"External Reviewers Involved","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information"}}]}}