{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,3,26]],"date-time":"2025-03-26T03:28:28Z","timestamp":1742959708639,"version":"3.40.3"},"publisher-location":"Cham","reference-count":35,"publisher":"Springer International Publishing","isbn-type":[{"type":"print","value":"9783030210731"},{"type":"electronic","value":"9783030210748"}],"license":[{"start":{"date-parts":[[2019,1,1]],"date-time":"2019-01-01T00:00:00Z","timestamp":1546300800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019]]},"DOI":"10.1007\/978-3-030-21074-8_17","type":"book-chapter","created":{"date-parts":[[2019,6,18]],"date-time":"2019-06-18T10:10:14Z","timestamp":1560852614000},"page":"215-228","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Automatic Retinal and Choroidal Boundary Segmentation in OCT Images Using Patch-Based Supervised Machine Learning Methods"],"prefix":"10.1007","author":[{"given":"David","family":"Alonso-Caneiro","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jason","family":"Kugelman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jared","family":"Hamwood","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Scott A.","family":"Read","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stephen J.","family":"Vincent","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fred K.","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael J.","family":"Collins","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2019,6,19]]},"reference":[{"key":"17_CR1","doi-asserted-by":"publisher","first-page":"1178","DOI":"10.1126\/science.1957169","volume":"254","author":"D Huang","year":"1991","unstructured":"Huang, D., et al.: Optical coherence tomography. Science 254, 1178\u20131181 (1991)","journal-title":"Science"},{"key":"17_CR2","doi-asserted-by":"publisher","first-page":"3248","DOI":"10.1364\/BOE.8.003248","volume":"8","author":"JF Boer de","year":"2017","unstructured":"de Boer, J.F., Leitgeb, R., Wojtkowski, M.: Twenty-five years of optical coherence tomography: the paradigm shift in sensitivity and speed provided by Fourier domain OCT. Biomed. Opt. Express 8, 3248\u20133280 (2017)","journal-title":"Biomed. Opt. Express"},{"key":"17_CR3","doi-asserted-by":"publisher","first-page":"3586","DOI":"10.1167\/iovs.13-11732","volume":"54","author":"SA Read","year":"2013","unstructured":"Read, S.A., Collins, M.J., Vincent, S.J., Alonso-Caneiro, D.: Choroidal thickness in childhood. Invest. Ophthalmol. Vis. Sci. 54, 3586 (2013)","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"17_CR4","doi-asserted-by":"publisher","first-page":"1223","DOI":"10.1097\/IAE.0000000000000464","volume":"35","author":"SA Read","year":"2015","unstructured":"Read, S.A., Collins, M.J., Vincent, S.J., Alonso-Caneiro, D.: Macular retinal layer thickness in childhood. Retina 35, 1223\u20131233 (2015)","journal-title":"Retina"},{"key":"17_CR5","doi-asserted-by":"publisher","first-page":"266","DOI":"10.1016\/j.ajo.2009.03.006","volume":"148","author":"S Grover","year":"2009","unstructured":"Grover, S., Murthy, R.K., Brar, V.S., Chalam, K.V.: Normative data for macular thickness by high-definition spectral-domain optical coherence tomography (spectralis). Am. J. Ophthalmol. 148, 266\u2013271 (2009)","journal-title":"Am. J. Ophthalmol."},{"key":"17_CR6","doi-asserted-by":"publisher","first-page":"811","DOI":"10.1016\/j.ajo.2008.12.008","volume":"147","author":"R Margolis","year":"2009","unstructured":"Margolis, R., Spaide, R.F.: A pilot study of enhanced depth imaging optical coherence tomography of the choroid in normal eyes. Am. J. Ophthalmol. 147, 811\u2013815 (2009)","journal-title":"Am. J. Ophthalmol."},{"key":"17_CR7","doi-asserted-by":"publisher","first-page":"620","DOI":"10.1097\/OPX.0b013e318251293a","volume":"89","author":"E Harb","year":"2012","unstructured":"Harb, E., Hyman, L., Fazzari, M., Gwiazda, J., Marsh-Tootle, W.: Factors associated with macular thickness in the comet myopic cohort. Optom. Vis. Sci. 89, 620\u2013631 (2012)","journal-title":"Optom. Vis. Sci."},{"key":"17_CR8","doi-asserted-by":"publisher","first-page":"7578","DOI":"10.1167\/iovs.13-12772","volume":"54","author":"SA Read","year":"2013","unstructured":"Read, S.A., Collins, M.J., Vincent, S.J., Alonso-Caneiro, D.: Choroidal thickness in myopic and nonmyopic children assessed with enhanced depth imaging optical coherence tomography. Invest. Ophthalmol. Vis. Sci. 54, 7578 (2013)","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"17_CR9","doi-asserted-by":"publisher","first-page":"5062","DOI":"10.1167\/iovs.09-4954","volume":"51","author":"A Sakamoto","year":"2010","unstructured":"Sakamoto, A., et al.: Three-dimensional imaging of the macular retinal nerve fiber layer in glaucoma with spectral-domain optical coherence tomography. Invest. Ophthalmol. Vis. Sci. 51, 5062 (2010)","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"17_CR10","doi-asserted-by":"publisher","first-page":"1030","DOI":"10.1016\/j.ajo.2011.05.021","volume":"152","author":"A Wood","year":"2011","unstructured":"Wood, A., Binns, A., Margrain, T., Drexler, W., Pova\u017eay, B., Esmaeelpour, M., Sheen, N.: Retinal and choroidal thickness in early age-related macular degeneration. Am. J. Ophthalmol. 152, 1030\u20131038.e2 (2011)","journal-title":"Am. J. Ophthalmol."},{"key":"17_CR11","doi-asserted-by":"publisher","first-page":"ii15","DOI":"10.1136\/bjophthalmol-2013-304326","volume":"98","author":"II Bussel","year":"2014","unstructured":"Bussel, I.I., Wollstein, G., Schuman, J.S.: OCT for glaucoma diagnosis, screening and detection of glaucoma progression. Br. J. Ophthalmol. 98, ii15\u2013ii19 (2014)","journal-title":"Br. J. Ophthalmol."},{"key":"17_CR12","doi-asserted-by":"publisher","first-page":"536","DOI":"10.1016\/j.ajo.2011.08.008","volume":"153","author":"FJL Medina","year":"2012","unstructured":"Medina, F.J.L., Call\u00e9n, C.I., Rebolleda, G., Mu\u00f1oz-Negrete, F.J., Call\u00e9n, M.J.I., del Valle, F.G.: Use of nonmydriatic spectral-domain optical coherence tomography for diagnosing diabetic macular edema. Am. J. Ophthalmol. 153, 536\u2013543.e1 (2012)","journal-title":"Am. J. Ophthalmol."},{"key":"17_CR13","doi-asserted-by":"publisher","first-page":"566","DOI":"10.1016\/j.ajo.2007.01.028","volume":"143","author":"AE Fung","year":"2007","unstructured":"Fung, A.E., et al.: An optical coherence tomography-guided, variable dosing regimen with intravitreal ranibizumab (lucentis) for neovascular age-related macular degeneration. Am. J. Ophthalmol. 143, 566\u2013583.e2 (2007)","journal-title":"Am. J. Ophthalmol."},{"key":"17_CR14","first-page":"603","volume":"5","author":"A Baghaie","year":"2015","unstructured":"Baghaie, A., Yu, Z., D\u2019Souza, R.M.: State-of-the-art in retinal optical coherence tomography image analysis. Quant. Imaging Med. Surg. 5, 603 (2015)","journal-title":"Quant. Imaging Med. Surg."},{"key":"17_CR15","unstructured":"DeBuc, D.C.: A review of algorithms for segmentation of retinal image data using optical coherence tomography. In: Image Segmentation. InTech (2011)"},{"key":"17_CR16","doi-asserted-by":"publisher","first-page":"1743","DOI":"10.1364\/BOE.2.001743","volume":"2","author":"K Vermeer","year":"2011","unstructured":"Vermeer, K., Van der Schoot, J., Lemij, H., De Boer, J.: Automated segmentation by pixel classification of retinal layers in ophthalmic OCT images. Biomed. Opt. Express 2, 1743\u20131756 (2011)","journal-title":"Biomed. Opt. Express"},{"key":"17_CR17","doi-asserted-by":"publisher","first-page":"2732","DOI":"10.1364\/BOE.8.002732","volume":"8","author":"L Fang","year":"2017","unstructured":"Fang, L., Cunefare, D., Wang, C., Guymer, R.H., Li, S., Farsiu, S.: Automatic segmentation of nine retinal layer boundaries in OCT images of non-exudative amd patients using deep learning and graph search. Biomed. Opt. Express 8, 2732\u20132744 (2017)","journal-title":"Biomed. Opt. Express"},{"key":"17_CR18","doi-asserted-by":"publisher","first-page":"1133","DOI":"10.1364\/BOE.4.001133","volume":"4","author":"A Lang","year":"2013","unstructured":"Lang, A., et al.: Retinal layer segmentation of macular OCT images using boundary classification. Biomed. Opt. Express 4, 1133\u20131152 (2013)","journal-title":"Biomed. Opt. Express"},{"key":"17_CR19","unstructured":"Ben-Cohen, A., et al.: Retinal layers segmentation using fully convolutional network in OCT images. RSIP Vision (2017)"},{"key":"17_CR20","doi-asserted-by":"crossref","unstructured":"Pekala, M., Joshi, N., Freund, D.E., Bressler, N.M., DeBuc, D.C., Burlina, P.M.: Deep learning based retinal OCT segmentation. CoRR abs\/1801.09749 (2018)","DOI":"10.1016\/j.compbiomed.2019.103445"},{"key":"17_CR21","doi-asserted-by":"publisher","first-page":"3049","DOI":"10.1364\/BOE.9.003049","volume":"9","author":"J Hamwood","year":"2018","unstructured":"Hamwood, J., Alonso-Caneiro, D., Read, S.A., Vincent, S.J., Collins, M.J.: Effect of patch size and network architecture on a convolutional neural network approach for automatic segmentation of OCT retinal layers. Biomed. Opt. Express 9, 3049\u20133066 (2018)","journal-title":"Biomed. Opt. Express"},{"key":"17_CR22","unstructured":"Chen, J., Yang, L., Zhang, Y., Alber, M., Chen, D.Z.: Combining fully convolutional and recurrent neural networks for 3D biomedical image segmentation. In: Proceedings of the 30th International Conference on Neural Information Processing Systems, NIPS 2016, USA, pp. 3044\u20133052. Curran Associates Inc. (2016)"},{"key":"17_CR23","series-title":"Lecture Notes in Computer Science","doi-asserted-by":"publisher","first-page":"507","DOI":"10.1007\/978-3-319-24553-9_62","volume-title":"Medical Image Computing and Computer-Assisted Intervention \u2013 MICCAI 2015","author":"H Chen","year":"2015","unstructured":"Chen, H., et al.: Automatic fetal ultrasound standard plane detection using knowledge transferred recurrent neural networks. In: Navab, N., Hornegger, J., Wells, W.M., Frangi, A.F. (eds.) MICCAI 2015. LNCS, vol. 9349, pp. 507\u2013514. Springer, Cham (2015). https:\/\/doi.org\/10.1007\/978-3-319-24553-9_62"},{"key":"17_CR24","doi-asserted-by":"publisher","first-page":"5759","DOI":"10.1364\/BOE.9.005759","volume":"9","author":"J Kugelman","year":"2018","unstructured":"Kugelman, J., Alonso-Caneiro, D., Read, S.A., Vincent, S.J., Collins, M.J.: Automatic segmentation of OCT retinal boundaries using recurrent neural networks and graph search. Biomed. Opt. Express 9, 5759\u20135777 (2018)","journal-title":"Biomed. Opt. Express"},{"key":"17_CR25","doi-asserted-by":"publisher","first-page":"1735","DOI":"10.1162\/neco.1997.9.8.1735","volume":"9","author":"S Hochreiter","year":"1997","unstructured":"Hochreiter, S., Schmidhuber, J.: Long short-term memory. Neural Comput. 9, 1735\u20131780 (1997)","journal-title":"Neural Comput."},{"key":"17_CR26","doi-asserted-by":"crossref","unstructured":"Cho, K., et al.: Learning phrase representations using RNN encoder-decoder for statistical machine translation. arXiv preprint arXiv:1406.1078 (2014)","DOI":"10.3115\/v1\/D14-1179"},{"key":"17_CR27","unstructured":"Visin, F., Kastner, K., Cho, K., Matteucci, M., Courville, A., Bengio, Y.: ReNet: a recurrent neural network based alternative to convolutional networks. arXiv preprint arXiv:1505.00393 (2015)"},{"key":"17_CR28","unstructured":"Kingma, D.P., Ba, J.: Adam: a method for stochastic optimization. arXiv preprint arXiv:1412.6980 (2014)"},{"key":"17_CR29","doi-asserted-by":"publisher","first-page":"7738","DOI":"10.1167\/iovs.10-6925","volume":"52","author":"MJ Girard","year":"2011","unstructured":"Girard, M.J., Strouthidis, N.G., Ethier, C.R., Mari, J.M.: Shadow removal and contrast enhancement in optical coherence tomography images of the human optic nerve head. Invest. Ophthalmol. Vis. Sci. 52, 7738\u20137748 (2011)","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"17_CR30","doi-asserted-by":"publisher","first-page":"322","DOI":"10.1364\/BOE.5.000322","volume":"5","author":"K Vermeer","year":"2014","unstructured":"Vermeer, K., Mo, J., Weda, J., Lemij, H., De Boer, J.: Depth-resolved model-based reconstruction of attenuation coefficients in optical coherence tomography. Biomed. Opt. Express 5, 322\u2013337 (2014)","journal-title":"Biomed. Opt. Express"},{"key":"17_CR31","doi-asserted-by":"publisher","first-page":"269","DOI":"10.1007\/BF01386390","volume":"1","author":"EW Dijkstra","year":"1959","unstructured":"Dijkstra, E.W.: A note on two problems in connexion with graphs. Numer. Math. 1, 269\u2013271 (1959)","journal-title":"Numer. Math."},{"key":"17_CR32","doi-asserted-by":"publisher","first-page":"2795","DOI":"10.1364\/BOE.4.002795","volume":"4","author":"D Alonso-Caneiro","year":"2013","unstructured":"Alonso-Caneiro, D., Read, S.A., Collins, M.J.: Automatic segmentation of choroidal thickness in optical coherence tomography. Biomed. Opt. Express 4, 2795\u20132812 (2013)","journal-title":"Biomed. Opt. Express"},{"key":"17_CR33","unstructured":"He, Y., et al.: Topology guaranteed segmentation of the human retina from OCT using convolutional neural networks. CoRR abs\/1803.05120 (2018)"},{"key":"17_CR34","doi-asserted-by":"publisher","first-page":"4404","DOI":"10.1167\/iovs.18-24665","volume":"59","author":"E Chandrasekera","year":"2018","unstructured":"Chandrasekera, E., Wong, E.N., Sampson, D.M., Alonso-Caneiro, D., Chen, F.K.: Posterior choroidal stroma reduces accuracy of automated segmentation of outer choroidal boundary in swept source optical coherence tomography. Invest. Ophthalmol. Vis. Sci. 59, 4404\u20134412 (2018)","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"17_CR35","doi-asserted-by":"publisher","first-page":"1259","DOI":"10.1136\/bjo.2004.097022","volume":"90","author":"MEJ Velthoven van","year":"2006","unstructured":"van Velthoven, M.E.J., van der Linden, M.H., de Smet, M.D., Faber, D.J., Verbraak, F.D.: Influence of cataract on optical coherence tomography image quality and retinal thickness. Br. J. Ophthalmol. 90, 1259\u20131262 (2006)","journal-title":"Br. J. Ophthalmol."}],"container-title":["Lecture Notes in Computer Science","Computer Vision \u2013 ACCV 2018 Workshops"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-030-21074-8_17","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,11,29]],"date-time":"2019-11-29T07:14:02Z","timestamp":1575011642000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-030-21074-8_17"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019]]},"ISBN":["9783030210731","9783030210748"],"references-count":35,"URL":"https:\/\/doi.org\/10.1007\/978-3-030-21074-8_17","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"type":"print","value":"0302-9743"},{"type":"electronic","value":"1611-3349"}],"subject":[],"published":{"date-parts":[[2019]]},"assertion":[{"value":"19 June 2019","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}},{"value":"ACCV","order":1,"name":"conference_acronym","label":"Conference Acronym","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Asian Conference on Computer Vision","order":2,"name":"conference_name","label":"Conference Name","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Perth, WA","order":3,"name":"conference_city","label":"Conference City","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Australia","order":4,"name":"conference_country","label":"Conference Country","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2018","order":5,"name":"conference_year","label":"Conference Year","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2 December 2018","order":7,"name":"conference_start_date","label":"Conference Start Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"6 December 2018","order":8,"name":"conference_end_date","label":"Conference End Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"14","order":9,"name":"conference_number","label":"Conference Number","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"accv2018","order":10,"name":"conference_id","label":"Conference ID","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"http:\/\/accv2018.net\/","order":11,"name":"conference_url","label":"Conference URL","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Double-blind","order":1,"name":"type","label":"Type","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"Microsoft CMT","order":2,"name":"conference_management_system","label":"Conference Management System","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"979","order":3,"name":"number_of_submissions_sent_for_review","label":"Number of Submissions Sent for Review","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"274","order":4,"name":"number_of_full_papers_accepted","label":"Number of Full Papers Accepted","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"0","order":5,"name":"number_of_short_papers_accepted","label":"Number of Short Papers Accepted","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"28% - The value is computed by the equation \"Number of Full Papers Accepted \/ Number of Submissions Sent for Review * 100\" and then rounded to a whole number.","order":6,"name":"acceptance_rate_of_full_papers","label":"Acceptance Rate of Full Papers","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"3","order":7,"name":"average_number_of_reviews_per_paper","label":"Average Number of Reviews per Paper","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"2.7","order":8,"name":"average_number_of_papers_per_reviewer","label":"Average Number of Papers per Reviewer","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"No","order":9,"name":"external_reviewers_involved","label":"External Reviewers Involved","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}}]}}