{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,3,26]],"date-time":"2025-03-26T08:33:11Z","timestamp":1742977991902,"version":"3.40.3"},"publisher-location":"Cham","reference-count":39,"publisher":"Springer International Publishing","isbn-type":[{"type":"print","value":"9783030238063"},{"type":"electronic","value":"9783030238070"}],"license":[{"start":{"date-parts":[[2019,1,1]],"date-time":"2019-01-01T00:00:00Z","timestamp":1546300800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019]]},"DOI":"10.1007\/978-3-030-23807-0_11","type":"book-chapter","created":{"date-parts":[[2019,6,28]],"date-time":"2019-06-28T02:20:06Z","timestamp":1561688406000},"page":"126-137","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Light Intensity-Modulated Bending Sensor Fabrication and Performance Test for Shape Sensing"],"prefix":"10.1007","author":[{"given":"Faisal","family":"ALJaber","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kaspar","family":"Althoefer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2019,6,28]]},"reference":[{"key":"11_CR1","unstructured":"Shi, C., Luo, X., Fukuda, T.: Shape sensing techniques for continuum robots in minimally invasive surgery: a survey. IEEE Trans. Biomed. Eng. PP(99) (2016)"},{"issue":"4","key":"11_CR2","doi-asserted-by":"publisher","first-page":"1115","DOI":"10.1109\/TMECH.2013.2269836","volume":"19","author":"RJ Roesthuis","year":"2013","unstructured":"Roesthuis, R.J., Kemp, M., van den Dobbelsteen, J.J.: Three-dimensional needle shape reconstruction using an array of fiber Bragg grating sensors. IEEE\/ASME Trans. Mechatron. 19(4), 1115\u20131126 (2013)","journal-title":"IEEE\/ASME Trans. Mechatron."},{"key":"11_CR3","doi-asserted-by":"crossref","unstructured":"Roesthuis, R.J., Janssen, S., Misra, S.: On using an array of fiber Bragg grating sensors for closed-loop control of flexible minimally invasive surgical instruments. In: IEEE\/RSJ International Conference on Intelligent Robots and Systems, Tokyo (2013)","DOI":"10.1109\/IROS.2013.6696715"},{"key":"11_CR4","doi-asserted-by":"crossref","unstructured":"Ryu, S.C., Dupont, P.E.: FBG-based shape sensing tubes for continuum robots. In: IEEE International Conference on Robotics and Automation (ICRA), Hong Kong (2014)","DOI":"10.1109\/ICRA.2014.6907368"},{"key":"11_CR5","doi-asserted-by":"crossref","unstructured":"Abayazid, M., Kemp, M., Misra, S.: 3D flexible needle steering in soft-tissue phantoms using fiber Bragg grating sensors. In: 2013 IEEE International Conference on Robotics and Automation, Karlsruhe (2013)","DOI":"10.1109\/ICRA.2013.6631418"},{"issue":"5","key":"11_CR6","doi-asserted-by":"publisher","first-page":"287","DOI":"10.1016\/j.tibtech.2013.03.002","volume":"31","author":"S Kim","year":"2013","unstructured":"Kim, S., Laschi, C., Trimmer, B.: Soft robotics: a bioinspired evolution in robotics. Trends Biotechnol. 31(5), 287\u2013294 (2013)","journal-title":"Trends Biotechnol."},{"issue":"1","key":"11_CR7","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1089\/soro.2013.0001","volume":"1","author":"C Majidi","year":"2014","unstructured":"Majidi, C.: Soft robotics: a perspective\u2013current trends and prospects for the future. Soft Robot. 1(1), 5\u201311 (2014)","journal-title":"Soft Robot."},{"issue":"12","key":"11_CR8","doi-asserted-by":"publisher","first-page":"125029","DOI":"10.1088\/0960-1317\/20\/12\/125029","volume":"20","author":"Y-L Park","year":"2010","unstructured":"Park, Y.-L., Majidi, C., Kramer, R., Berard, P., Wood, R.J.: Hyperelastic pressure sensing with a liquid-embedded elastomer. J. Micromech. Microeng. 20(12), 125029 (2010)","journal-title":"J. Micromech. Microeng."},{"issue":"8","key":"11_CR9","doi-asserted-by":"publisher","first-page":"2711","DOI":"10.1109\/JSEN.2012.2200790","volume":"12","author":"Y-L Park","year":"2012","unstructured":"Park, Y.-L., Chen, B., Wood, R.J.: Design and fabrication of soft artificial skin using embedded microchannels and liquid conductors. IEEE Sens. J. 12(8), 2711\u20132718 (2012)","journal-title":"IEEE Sens. J."},{"issue":"207890","key":"11_CR10","doi-asserted-by":"publisher","first-page":"1740","DOI":"10.1039\/c0lc00620c","volume":"11","author":"C-Y Wu","year":"2011","unstructured":"Wu, C.-Y., Liao, W.H., Tung, Y.-C.: Integrated ionic liquid-based electrofluidic circuits for pressure sensing within polydimethylsiloxane microfluidic systems. Lab Chip 11(207890), 1740\u20131746 (2011)","journal-title":"Lab Chip"},{"key":"11_CR11","doi-asserted-by":"publisher","first-page":"1097","DOI":"10.1002\/adfm.200701216","volume":"18","author":"MD Dickey","year":"2008","unstructured":"Dickey, M.D., Chiechi, R.C., Larsen, R.J., Weiss, E.A., Weitz, D.A., Whitesides, G.M.: Eutectic gallium-indium (EGaIn): a liquid metal alloy for the formation of stable structures in microchannels at room temperature. Adv. Func. Mater. 18, 1097\u20131104 (2008)","journal-title":"Adv. Func. Mater."},{"key":"11_CR12","doi-asserted-by":"publisher","first-page":"443","DOI":"10.1109\/JMEMS.2011.2174421","volume":"21","author":"T Liu","year":"2012","unstructured":"Liu, T., Sen, P., Kim, C.: Characterization of nontoxic liquid-metal alloy Galinstan for applications in microdevices. J. Microelectromech. Syst. 21, 443\u2013450 (2012)","journal-title":"J. Microelectromech. Syst."},{"key":"11_CR13","doi-asserted-by":"publisher","first-page":"62","DOI":"10.1016\/j.sna.2012.03.023","volume":"179","author":"RP Wong","year":"2012","unstructured":"Wong, R.P., Posner, J., Santos, V.: Flexible microfluidic normal force sensor skin for tactile feedback. Sens. Actuators A 179, 62\u201369 (2012)","journal-title":"Sens. Actuators A"},{"issue":"10","key":"11_CR14","doi-asserted-by":"publisher","first-page":"4056","DOI":"10.1109\/JSEN.2013.2272320","volume":"13","author":"DM Vogt","year":"2013","unstructured":"Vogt, D.M., Park, Y.-L., Wood, R.J.: Design and characterization of a soft multi-axis force sensor using embedded microfluidic channels. IEEE Sens. J. 13(10), 4056\u20134064 (2013)","journal-title":"IEEE Sens. J."},{"key":"11_CR15","doi-asserted-by":"publisher","first-page":"105017","DOI":"10.1088\/0964-1726\/20\/10\/105017","volume":"20","author":"C Majidi","year":"2011","unstructured":"Majidi, C., Kramer, R., Wood, R.J.: A non-differential elastomer curvature sensor for softer-than-skin electronics. Smart Mater. Struct. 20, 105017 (2011)","journal-title":"Smart Mater. Struct."},{"key":"11_CR16","doi-asserted-by":"publisher","DOI":"10.1021\/bk-2012-1117","volume-title":"Ionic Liquids: Science and Applications","author":"A Visser","year":"2012","unstructured":"Visser, A., Bridges, N., Rogers, R.: Ionic Liquids: Science and Applications, vol. 1117. American Chemical Society, Washington, D.C. (2012)"},{"issue":"9","key":"11_CR17","doi-asserted-by":"publisher","first-page":"3405","DOI":"10.1109\/JSEN.2013.2263797","volume":"13","author":"J-B Chossat","year":"2013","unstructured":"Chossat, J.-B., Park, Y.-L., Wood, R.J., Duchaine, V.: A soft strain sensor based on ionic and metal liquids. IEEE Sens. J. 13(9), 3405\u20133414 (2013)","journal-title":"IEEE Sens. J."},{"key":"11_CR18","doi-asserted-by":"crossref","unstructured":"Chossat, J.-B., Shin, H.-S., Park, Y.-L., Duchaine, V.: Design and manufacturing of soft tactile skin using an embedded ionic liquid and tomographic imaging. J. Mech. Robot. (2014)","DOI":"10.1115\/1.4029474"},{"issue":"1","key":"11_CR19","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1682\/JRRD.2010.02.0013","volume":"48","author":"K Li","year":"2011","unstructured":"Li, K., Chen, I.-M., Yeo, S.H., Lim, C.K.: Development of finger-motion capturing device based on optical linear encoder. J. Rehabil. Res. Dev. 48(1), 69 (2011)","journal-title":"J. Rehabil. Res. Dev."},{"issue":"4","key":"11_CR20","doi-asserted-by":"publisher","first-page":"6854","DOI":"10.3390\/s140406854","volume":"14","author":"P Kampmann","year":"2014","unstructured":"Kampmann, P., Kirchner, F.: Integration of fiber-optic sensor arrays into a multi-modal tactile sensor processing system for robotic end-effectors. Sensors 14(4), 6854\u20136876 (2014)","journal-title":"Sensors"},{"issue":"7","key":"11_CR21","doi-asserted-by":"publisher","first-page":"1215","DOI":"10.1109\/JSEN.2008.926518","volume":"8","author":"A Grillet","year":"2008","unstructured":"Grillet, A., et al.: Optical fiber sensors embedded into medical textiles for healthcare monitoring. IEEE Sens. J. 8(7), 1215\u20131222 (2008)","journal-title":"IEEE Sens. J."},{"issue":"3","key":"11_CR22","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1016\/j.aeue.2006.12.003","volume":"61","author":"S Kopetz","year":"2007","unstructured":"Kopetz, S., Cai, D., Rabe, E., Neyer, A.: PDMS-based optical waveguide layer for integration in electrical\u2013optical circuit boards. AEU-Int. J. Electron. Commun. 61(3), 163\u2013167 (2007)","journal-title":"AEU-Int. J. Electron. Commun."},{"issue":"6","key":"11_CR23","doi-asserted-by":"publisher","first-page":"2088","DOI":"10.1109\/JLT.2005.849932","volume":"23","author":"D Chang-Yen","year":"2005","unstructured":"Chang-Yen, D., Eich, R., Gale, B.: A monolithic PDMS waveguide system fabricated using soft-lithography techniques. J. Lightwave Technol. 23(6), 2088\u20132093 (2005)","journal-title":"J. Lightwave Technol."},{"issue":"2","key":"11_CR24","doi-asserted-by":"publisher","first-page":"532","DOI":"10.1016\/j.snb.2008.05.040","volume":"134","author":"JS Kee","year":"2008","unstructured":"Kee, J.S., Poenar, D.P., Neuzil, P., Yobas, L.: Monolithic integration of poly(dimethylsiloxane) waveguides and microfluidics for on-chip absorbance measurements. Sens. Actuators B 134(2), 532\u2013538 (2008)","journal-title":"Sens. Actuators B"},{"key":"11_CR25","doi-asserted-by":"crossref","unstructured":"To, C., Hellebrekers, T.L., Park, Y.-L.: Highly stretchable optical sensors for pressure, strain, and curvature measurement. In: IEEE\/RSJ International Conference on Intelligent Robots and Systems (IROS), Hamburg (2015)","DOI":"10.1109\/IROS.2015.7354215"},{"key":"11_CR26","unstructured":"Fidanboylu, K.: Fiber optic sensors and their applications (2009)"},{"key":"11_CR27","unstructured":"M\u00e9ndez, A.: Overview of fiber optic sensors for NDT applications. In: IV NDT Panamerican Conference, pp. 1\u201311 (2007)"},{"key":"11_CR28","unstructured":"Jones, D., Introduction to Fiber Optics. Naval Education and Training Professional Development and Technology Center (1998)"},{"key":"11_CR29","volume-title":"Fundemantals of Fiber Optics: An Introduction for Beginners","author":"R Jenny","year":"2000","unstructured":"Jenny, R.: Fundemantals of Fiber Optics: An Introduction for Beginners. Volpi Manufacturing USA Co., New York (2000)"},{"key":"11_CR30","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/28.67537","volume":"27","author":"PM Tracey","year":"1991","unstructured":"Tracey, P.M.: Intrinsic fiber-optic sensors. IEEE Trans. Ind. Appl. 27, 1 (1991)","journal-title":"IEEE Trans. Ind. Appl."},{"issue":"3","key":"11_CR31","doi-asserted-by":"publisher","first-page":"721","DOI":"10.1109\/TBME.2010.2095853","volume":"58","author":"P Polygerinos","year":"2011","unstructured":"Polygerinos, P., Ataollahi, A., Schaeffter, T., Razavi, R., Seneviratne, L.D., Althoefer, K.: MRI-compatible intensity-modulated force sensor for cardiac catheterization procedures. IEEE Trans. Biomed. Eng. 58(3), 721\u2013726 (2011)","journal-title":"IEEE Trans. Biomed. Eng."},{"issue":"4","key":"11_CR32","doi-asserted-by":"publisher","first-page":"1408","DOI":"10.1109\/TIM.2010.2085270","volume":"60","author":"P Polygerinos","year":"2011","unstructured":"Polygerinos, P., Seneviratne, L.D., Althoefer, K.: Modeling of light intensity-modulated fiber-optic displacement sensors. IEEE Trans. Instrum. Meas. 60(4), 1408\u20131415 (2011)","journal-title":"IEEE Trans. Instrum. Meas."},{"issue":"2","key":"11_CR33","doi-asserted-by":"publisher","first-page":"283","DOI":"10.1109\/TIM.2009.2023147","volume":"59","author":"P Puangmali","year":"2010","unstructured":"Puangmali, P., Althoefer, K., Seneviratne, L.D.: Mathematical modeling of intensity-modulated bent-tip optical fiber displacement sensors. IEEE Trans. Intrum. Meas. 59(2), 283\u2013291 (2010)","journal-title":"IEEE Trans. Intrum. Meas."},{"key":"11_CR34","volume-title":"Handbook of Modern Sensors","author":"J Fraden","year":"2004","unstructured":"Fraden, J.: Handbook of Modern Sensors, 3rd edn. Springer, New York (2004)","edition":"3"},{"key":"11_CR35","doi-asserted-by":"publisher","first-page":"337","DOI":"10.1007\/978-1-4020-9485-9_24","volume-title":"International Symposium on History of Machines and Mechanisms","author":"CH Kuo","year":"2009","unstructured":"Kuo, C.H., Dai, J.S.: Robotics for minimally invasive surgery: a historical review. In: Yan, H.S., Ceccarelli, M. (eds.) International Symposium on History of Machines and Mechanisms, pp. 337\u2013354. Springer, Dordrecht (2009). \n                      https:\/\/doi.org\/10.1007\/978-1-4020-9485-9_24"},{"issue":"5","key":"11_CR36","doi-asserted-by":"publisher","first-page":"653","DOI":"10.1243\/09544119JEIM591","volume":"224","author":"G Dogangil","year":"2010","unstructured":"Dogangil, G., Davies, B.L., Rodriguez y Baena, F.: A review of medical robotics for minimally invasive soft tissue surgery. Proc. Inst. Mech. Eng. Part H: J. Eng. Med. 224(5), 653\u2013679 (2010)","journal-title":"Proc. Inst. Mech. Eng. Part H: J. Eng. Med."},{"key":"11_CR37","first-page":"906","volume":"15","author":"YL Park","year":"2010","unstructured":"Park, Y.L., Elayaperumal, S., Daniel, B., Ryu, S.C., Shin, M., Savall, J., et al.: Real-time estimation of 3-D needle shape and deflection for MRI-guided interventions. IEEE ASME Trans. Mechatron. 15, 906\u2013915 (2010)","journal-title":"IEEE ASME Trans. Mechatron."},{"key":"11_CR38","doi-asserted-by":"publisher","first-page":"408","DOI":"10.3109\/13645706.2012.666251","volume":"21","author":"K Henken","year":"2012","unstructured":"Henken, K., Van Gerwen, D., Dankelman, J., Van Den Dobbelsteen, J.: Accuracy of needle position measurements using fiber Bragg gratings. Minim. Invasive Ther. Allied Technol.: MITAT: Off. J. Soc. Minim. Invasive Ther. 21, 408\u2013414 (2012)","journal-title":"Minim. Invasive Ther. Allied Technol.: MITAT: Off. J. Soc. Minim. Invasive Ther."},{"key":"11_CR39","doi-asserted-by":"crossref","unstructured":"Searle, T.C., Althoefer, K., Seneviratne, L., Liu, H.: An optical curvature sensor for flexible manipulators. In: 2013 IEEE International Conference on Robotics and Automation (ICRA), 6\u201310 May 2013, pp. 4415\u20134420 (2013)","DOI":"10.1109\/ICRA.2013.6631203"}],"container-title":["Lecture Notes in Computer Science","Towards Autonomous Robotic Systems"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-030-23807-0_11","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,6,28]],"date-time":"2019-06-28T21:26:02Z","timestamp":1561757162000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-030-23807-0_11"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019]]},"ISBN":["9783030238063","9783030238070"],"references-count":39,"URL":"https:\/\/doi.org\/10.1007\/978-3-030-23807-0_11","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"type":"print","value":"0302-9743"},{"type":"electronic","value":"1611-3349"}],"subject":[],"published":{"date-parts":[[2019]]},"assertion":[{"value":"28 June 2019","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}},{"value":"TAROS","order":1,"name":"conference_acronym","label":"Conference Acronym","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Annual Conference Towards Autonomous Robotic Systems","order":2,"name":"conference_name","label":"Conference Name","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"London","order":3,"name":"conference_city","label":"Conference City","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"United Kingdom","order":4,"name":"conference_country","label":"Conference Country","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2019","order":5,"name":"conference_year","label":"Conference Year","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"3 July 2019","order":7,"name":"conference_start_date","label":"Conference Start Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"5 July 2019","order":8,"name":"conference_end_date","label":"Conference End Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"20","order":9,"name":"conference_number","label":"Conference Number","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"taros2019","order":10,"name":"conference_id","label":"Conference ID","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"https:\/\/www.qmul.ac.uk\/robotics\/events\/taros2019\/","order":11,"name":"conference_url","label":"Conference URL","group":{"name":"ConferenceInfo","label":"Conference Information"}}]}}