{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,9]],"date-time":"2026-03-09T19:38:50Z","timestamp":1773085130899,"version":"3.50.1"},"publisher-location":"Cham","reference-count":36,"publisher":"Springer International Publishing","isbn-type":[{"value":"9783030247409","type":"print"},{"value":"9783030247416","type":"electronic"}],"license":[{"start":{"date-parts":[[2019,1,1]],"date-time":"2019-01-01T00:00:00Z","timestamp":1546300800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019]]},"DOI":"10.1007\/978-3-030-24741-6_9","type":"book-chapter","created":{"date-parts":[[2019,7,5]],"date-time":"2019-07-05T10:02:48Z","timestamp":1562320968000},"page":"101-113","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":12,"title":["Characterization of Biomimetic Peristaltic Pumping System Based on Flexible Silicone Soft Robotic Actuators as an Alternative for Technical Pumps"],"prefix":"10.1007","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7225-1472","authenticated-orcid":false,"given":"Falk","family":"Esser","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Friederike","family":"Kr\u00fcger","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5465-8252","authenticated-orcid":false,"given":"Tom","family":"Masselter","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2245-2636","authenticated-orcid":false,"given":"Thomas","family":"Speck","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2019,7,6]]},"reference":[{"key":"9_CR1","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1016\/S0262-1762(04)00062-8","volume":"2004","author":"B Nesbitt","year":"2004","unstructured":"Nesbitt, B.: When is a tube not a tube? When it\u2019s a pump! World Pumps 2004, 20\u201323 (2004)","journal-title":"World Pumps"},{"key":"9_CR2","unstructured":"Krutzsch, W.C., Cooper, P.: Introduction: classification and selection of pumps. In: Karassik, I.J., Cooper, P., Messina, J.P., and Heald, C.C. (eds.) Pump Handbook. Mc Graw Hill (2008)"},{"key":"9_CR3","unstructured":"Pierburg Pump Technology GmbH: Water circulation pump\u2013compact and versatile (2018). \n                      http:\/\/www.kspg.com"},{"key":"9_CR4","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1007\/s12038-007-0021-4","volume":"32","author":"S Vogel","year":"2007","unstructured":"Vogel, S.: Living in a physical world X. Pumping fluids through conduits. J. Biosci. 32, 207\u2013222 (2007)","journal-title":"J. Biosci."},{"key":"9_CR5","doi-asserted-by":"publisher","first-page":"051001","DOI":"10.1088\/1748-3190\/10\/5\/051001","volume":"10","author":"D Bach","year":"2015","unstructured":"Bach, D., Schmich, F., Masselter, T., Speck, T.: A review of selected pumping systems in nature and engineering\u2014potential biomimetic concepts for improving displacement pumps and pulsation damping. Bioinspir. Biomim. 10, 051001 (2015)","journal-title":"Bioinspir. Biomim."},{"key":"9_CR6","doi-asserted-by":"publisher","first-page":"250","DOI":"10.1152\/ajplegacy.1911.29.2.250","volume":"29","author":"WB Cannon","year":"1911","unstructured":"Cannon, W.B.: The nature of gastric peristalsis. Am. J. Physiol.-Leg. Content. 29, 250\u2013266 (1911)","journal-title":"Am. J. Physiol.-Leg. Content."},{"key":"9_CR7","doi-asserted-by":"publisher","first-page":"1163","DOI":"10.1242\/jeb.048793","volume":"214","author":"BH Kim","year":"2011","unstructured":"Kim, B.H., Kim, H.K., Lee, S.J.: Experimental analysis of the blood-sucking mechanism of female mosquitoes. J. Exp. Biol. 214, 1163\u20131169 (2011)","journal-title":"J. Exp. Biol."},{"key":"9_CR8","first-page":"464","volume":"82","author":"S Vogel","year":"1994","unstructured":"Vogel, S.: Nature\u2019s pumps. Am. Sci. 82, 464\u2013471 (1994)","journal-title":"Am. Sci."},{"key":"9_CR9","unstructured":"Esser, F., Bach, D., Masselter, T., Speck, T.: Nature as concept generator for novel biomimetic pumping systems. In: Kesel, A.B. and Zehren, D. (eds.) Bionik: Patente aus der Natur, Tagungsbeitr\u00e4ge zum 8. Bionik-Kongress in Bremen, pp. 116\u2013122 (2017)"},{"key":"9_CR10","doi-asserted-by":"publisher","first-page":"637","DOI":"10.1098\/rsif.2007.0218","volume":"4","author":"P Fratzl","year":"2007","unstructured":"Fratzl, P.: Biomimetic materials research: what can we really learn from nature\u2019s structural materials? J. Roy. Soc. Interface 4, 637\u2013642 (2007)","journal-title":"J. Roy. Soc. Interface"},{"key":"9_CR11","series-title":"Lecture Notes in Computer Science (Lecture Notes in Artificial Intelligence)","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1007\/978-3-319-95972-6_17","volume-title":"Biomimetic and Biohybrid Systems","author":"F Esser","year":"2018","unstructured":"Esser, F., Kr\u00fcger, F., Masselter, T., Speck, T.: Development and characterization of a novel biomimetic peristaltic pumping system with flexible silicone-based soft robotic ring actuators. In: Vouloutsi, V., et al. (eds.) Living Machines 2018. LNCS (LNAI), vol. 10928, pp. 157\u2013167. Springer, Cham (2018). \n                      https:\/\/doi.org\/10.1007\/978-3-319-95972-6_17"},{"key":"9_CR12","series-title":"Lecture Notes in Computer Science (Lecture Notes in Artificial Intelligence)","doi-asserted-by":"publisher","first-page":"138","DOI":"10.1007\/978-3-319-63537-8_12","volume-title":"Biomimetic and Biohybrid Systems","author":"F Esser","year":"2017","unstructured":"Esser, F., Steger, T., Bach, D., Masselter, T., Speck, T.: Development of novel foam-based soft robotic ring actuators for a biomimetic peristaltic pumping system. In: Mangan, M., Cutkosky, M., Mura, A., Verschure, P.F.M.J., Prescott, T., Lepora, N. (eds.) Living Machines 2017. LNCS (LNAI), vol. 10384, pp. 138\u2013147. Springer, Cham (2017). \n                      https:\/\/doi.org\/10.1007\/978-3-319-63537-8_12"},{"key":"9_CR13","doi-asserted-by":"publisher","first-page":"492","DOI":"10.1016\/j.compbiomed.2012.01.002","volume":"42","author":"MD Sinnott","year":"2012","unstructured":"Sinnott, M.D., Cleary, P.W., Arkwright, J.W., Dinning, P.G.: Investigating the relationships between peristaltic contraction and fluid transport in the human colon using smoothed particle hydrodynamics. Comput. Biol. Med. 42, 492\u2013503 (2012)","journal-title":"Comput. Biol. Med."},{"key":"9_CR14","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1504\/IJBBR.2013.058719","volume":"2","author":"S Dirven","year":"2013","unstructured":"Dirven, S., Xu, W., Cheng, L.K., Allen, J., Bronlund, J.: Biologically-inspired swallowing robot for investigation of texture modified foods. Int. J. Biomechatronics Biomed. Robot. 2, 163\u2013171 (2013)","journal-title":"Int. J. Biomechatronics Biomed. Robot."},{"key":"9_CR15","doi-asserted-by":"crossref","unstructured":"Yoshihama, S., Takano, S., Yamada, Y., Nakamura, T., Kato, K.: Powder conveyance experiments with peristaltic conveyor using a pneumatic artificial muscle. In: 2016 IEEE International Conference on Advanced Intelligent Mechatronics (AIM), pp. 1539\u20131544 (2016)","DOI":"10.1109\/AIM.2016.7576989"},{"key":"9_CR16","doi-asserted-by":"publisher","first-page":"105016","DOI":"10.1088\/0964-1726\/24\/10\/105016","volume":"24","author":"D McCoul","year":"2015","unstructured":"McCoul, D., Pei, Q.: Tubular dielectric elastomer actuator for active fluidic control. Smart Mater. Struct. 24, 105016 (2015)","journal-title":"Smart Mater. Struct."},{"key":"9_CR17","unstructured":"Sun, X., Hao, Y., Guo, S., Ye, X., Yan, X.: The development of a new type of compound peristaltic micropump. In: 2008 IEEE International Conference on Robotics and Biomimetics, pp. 698\u2013702 (2009)"},{"key":"9_CR18","doi-asserted-by":"crossref","unstructured":"Lotz, P., Matysek, M., Schlaak, H.F.: Peristaltic pump made of dielectric elastomer actuators. In: Electroactive Polymer Actuators and Devices (EAPAD) 2009. International Society for Optics and Photonics, pp. 72872 (2009)","DOI":"10.1117\/12.819216"},{"key":"9_CR19","doi-asserted-by":"publisher","first-page":"3845","DOI":"10.1002\/adfm.201203572","volume":"23","author":"R Fuhrer","year":"2013","unstructured":"Fuhrer, R., Schumacher, C.M., Zeltner, M., Stark, W.J.: Soft iron\/silicon composite tubes for magnetic peristaltic pumping: frequency-dependent pressure and volume flow. Adv. Funct. Mater. 23, 3845\u20133849 (2013)","journal-title":"Adv. Funct. Mater."},{"key":"9_CR20","unstructured":"Feygin, I.: Pressure actuated peristaltic pump (1993). \n                      https:\/\/patents.google.com\/patent\/US5273406A\/en"},{"key":"9_CR21","doi-asserted-by":"publisher","first-page":"035701","DOI":"10.1088\/1361-6501\/aa544f","volume":"28","author":"S Dirven","year":"2017","unstructured":"Dirven, S., Allen, J., Xu, W.P., Cheng, L.K.: Soft-robotic esophageal swallowing as a clinically-inspired bolus rheometry technique. Meas. Sci. Technol. 28, 035701 (2017)","journal-title":"Meas. Sci. Technol."},{"key":"9_CR22","doi-asserted-by":"publisher","first-page":"1890","DOI":"10.1002\/anie.201006464","volume":"50","author":"F Ilievski","year":"2011","unstructured":"Ilievski, F., Mazzeo, A.D., Shepherd, R.F., Chen, X., Whitesides, G.M.: Soft robotics for chemists. Angew. Chem. Int. Ed. 50, 1890\u20131895 (2011)","journal-title":"Angew. Chem. Int. Ed."},{"key":"9_CR23","unstructured":"Smooth-on Inc. Safety data sheets (2018). \n                      https:\/\/www.smooth-on.com"},{"key":"9_CR24","volume-title":"Fundamentals of Fluid Mechanics","author":"BR Munson","year":"2010","unstructured":"Munson, B.R., Young, D.F., Okiishi, T.H.: Fundamentals of Fluid Mechanics, 6th edn. Wiley, New York (2010)","edition":"6"},{"key":"9_CR25","unstructured":"Fuchs Schmierstoffe GmbH. Datasheet TITAN G 52529.. \n                      https:\/\/www.fuchs.com\/de"},{"key":"9_CR26","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-658-18555-8","volume-title":"Hydraulik und Pneumatik","author":"H Watter","year":"2017","unstructured":"Watter, H.: Hydraulik und Pneumatik. Springer, Wiesbaden (2017). \n                      https:\/\/doi.org\/10.1007\/978-3-658-18555-8"},{"key":"9_CR27","volume-title":"Pump Handbook","author":"IJ Karassik","year":"2008","unstructured":"Karassik, I.J., Messina, J.P., Cooper, P., Heald, C.C.: Pump Handbook. Mcgraw-Hill Professional, New York (2008)"},{"key":"9_CR28","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1007\/978-3-662-25101-0_2","volume-title":"Radial- und Axialpumpen: Theorie","author":"AJ Stepanoff","year":"1957","unstructured":"Stepanoff, A.J.: Definitionen und Terminologie. In: Stepanoff, A.J. (ed.) Radial- und Axialpumpen: Theorie, pp. 16\u201323. Springer, Heidelberg (1957). \n                      https:\/\/doi.org\/10.1007\/978-3-662-25101-0_2"},{"key":"9_CR29","doi-asserted-by":"publisher","first-page":"P12","DOI":"10.1007\/978-3-642-17306-6_193","volume-title":"Dubbel","author":"H Tsch\u00f6ke","year":"2011","unstructured":"Tsch\u00f6ke, H., H\u00f6lz\u2020, H.: Verdr\u00e4ngerpumpen. In: Grote, K.-H., Feldhusen, J. (eds.) Dubbel, pp. P12\u2013P25. Springer, Heidelberg (2011). \n                      https:\/\/doi.org\/10.1007\/978-3-642-17306-6_193"},{"key":"9_CR30","volume-title":"Comparative Biomechanics: Life\u2019s Physical World","author":"S Vogel","year":"2013","unstructured":"Vogel, S.: Comparative Biomechanics: Life\u2019s Physical World, 2nd edn. Princeton University Press, Princeton (2013)","edition":"2"},{"key":"9_CR31","doi-asserted-by":"crossref","unstructured":"Wang, T., Ren, H.: Reduction of power consumption for fluidic soft robots using energy recovery technique. In: 2016 IEEE International Conference on Information and Automation (ICIA), pp. 1403\u20131408 (2016)","DOI":"10.1109\/ICInfA.2016.7832039"},{"key":"9_CR32","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1007\/978-3-540-79535-3_6","volume-title":"Hydraulik","author":"D Will","year":"2011","unstructured":"Will, D., Gebhardt, N., Nollau, R., Herschel, D., Str\u00f6hl, H.: Pumpen und Motoren. In: Will, D., Gebhardt, N. (eds.) Hydraulik, pp. 121\u2013176. Springer, Heidelberg (2011). \n                      https:\/\/doi.org\/10.1007\/978-3-540-79535-3_6"},{"key":"9_CR33","unstructured":"R Core Team: R: A language and environment for statistical computing (2017). \n                      https:\/\/www.R-project.org\/"},{"key":"9_CR34","series-title":"Handbuch f\u00fcr Entwicklung, Anlagenplanung und Betrieb","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-642-05479-2","volume-title":"Kreiselpumpen","author":"JF G\u00fclich","year":"2010","unstructured":"G\u00fclich, J.F.: Kreiselpumpen. Handbuch f\u00fcr Entwicklung, Anlagenplanung und Betrieb. Springer, Heidelberg (2010). \n                      https:\/\/doi.org\/10.1007\/978-3-642-05479-2"},{"key":"9_CR35","doi-asserted-by":"crossref","unstructured":"Bauer, P.D.-I.G.: Physikalische Grundlagen. In: \u00d6lhydraulik, pp. 17\u201353 (2011)","DOI":"10.1007\/978-3-8348-8244-8_2"},{"key":"9_CR36","doi-asserted-by":"crossref","unstructured":"Suzuki, K., Nakamura, T.: Development of a peristaltic pump based on bowel peristalsis using for artificial rubber muscle. In: 2010 IEEE\/RSJ International Conference on Intelligent Robots and Systems, pp. 3085\u20133090 (2010)","DOI":"10.1109\/IROS.2010.5653006"}],"container-title":["Lecture Notes in Computer Science","Biomimetic and Biohybrid Systems"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-030-24741-6_9","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,7,5]],"date-time":"2019-07-05T10:04:26Z","timestamp":1562321066000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-030-24741-6_9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019]]},"ISBN":["9783030247409","9783030247416"],"references-count":36,"URL":"https:\/\/doi.org\/10.1007\/978-3-030-24741-6_9","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"value":"0302-9743","type":"print"},{"value":"1611-3349","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019]]},"assertion":[{"value":"6 July 2019","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}},{"value":"Living Machines","order":1,"name":"conference_acronym","label":"Conference Acronym","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Conference on Biomimetic and Biohybrid Systems","order":2,"name":"conference_name","label":"Conference Name","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Nara","order":3,"name":"conference_city","label":"Conference City","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Japan","order":4,"name":"conference_country","label":"Conference Country","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2019","order":5,"name":"conference_year","label":"Conference Year","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"9 July 2019","order":7,"name":"conference_start_date","label":"Conference Start Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"12 July 2019","order":8,"name":"conference_end_date","label":"Conference End Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"8","order":9,"name":"conference_number","label":"Conference Number","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"lm0","order":10,"name":"conference_id","label":"Conference ID","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"http:\/\/livingmachinesconference.eu\/2019\/","order":11,"name":"conference_url","label":"Conference URL","group":{"name":"ConferenceInfo","label":"Conference Information"}}]}}