{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,11,19]],"date-time":"2024-11-19T17:48:06Z","timestamp":1732038486745},"publisher-location":"Cham","reference-count":17,"publisher":"Springer International Publishing","isbn-type":[{"type":"print","value":"9783030275259"},{"type":"electronic","value":"9783030275266"}],"license":[{"start":{"date-parts":[[2019,1,1]],"date-time":"2019-01-01T00:00:00Z","timestamp":1546300800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019]]},"DOI":"10.1007\/978-3-030-27526-6_7","type":"book-chapter","created":{"date-parts":[[2019,8,1]],"date-time":"2019-08-01T20:26:01Z","timestamp":1564691161000},"page":"73-82","update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Concept and Prototype Design of a Soft Knee Exoskeleton with Continuum Structure (SoftKEX)"],"prefix":"10.1007","author":[{"given":"Zhihao","family":"Zhou","sequence":"first","affiliation":[]},{"given":"Xiuhua","family":"Liu","sequence":"additional","affiliation":[]},{"given":"Qining","family":"Wang","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2019,8,2]]},"reference":[{"issue":"2","key":"7_CR1","doi-asserted-by":"publisher","first-page":"171","DOI":"10.1109\/TNSRE.2016.2521160","volume":"25","author":"AJ Young","year":"2017","unstructured":"Young, A.J., Ferris, D.P.: State of the art and future directions for lower limb robotic exoskeletons. IEEE Trans. Neural Syst. Rehabil. Eng. 25(2), 171\u2013182 (2017). \n                      https:\/\/doi.org\/10.1109\/TNSRE.2016.2521160","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"issue":"4","key":"7_CR2","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1109\/MRA.2014.2360283","volume":"21","author":"AT Asbeck","year":"2014","unstructured":"Asbeck, A.T., De Rossi, S.M.M., Galiana, I., Ding, Y., Walsh, C.J.: Stronger, smarter, softer: next-generation wearable robots. IEEE Robot. Autom. Mag. 21(4), 22\u201333 (2014). \n                      https:\/\/doi.org\/10.1109\/MRA.2014.2360283","journal-title":"IEEE Robot. Autom. Mag."},{"issue":"6","key":"7_CR3","doi-asserted-by":"publisher","first-page":"744","DOI":"10.1177\/0278364914562476","volume":"34","author":"AT Asbeck","year":"2015","unstructured":"Asbeck, A.T., De Rossi, S.M.M., Holt, K.G., Walsh, C.J.: A biologically inspired soft exosuit for walking assistance. Int. J. Robot. Res. 34(6), 744\u2013762 (2015). \n                      https:\/\/doi.org\/10.1177\/0278364914562476","journal-title":"Int. J. Robot. Res."},{"key":"7_CR4","doi-asserted-by":"publisher","first-page":"eaai9084","DOI":"10.1126\/scitranslmed.aai9084","volume":"9","author":"LN Awad","year":"2017","unstructured":"Awad, L.N., et al.: A soft robotic exosuit improves walking in patients after stroke. Sci. Transl. Med. 9, eaai9084 (2017). \n                      https:\/\/doi.org\/10.1126\/scitranslmed.aai9084","journal-title":"Sci. Transl. Med."},{"issue":"4","key":"7_CR5","doi-asserted-by":"publisher","first-page":"847","DOI":"10.1109\/TNSRE.2018.2815656","volume":"26","author":"X Jin","year":"2018","unstructured":"Jin, X., Prado, A., Agrawal, S.K.: Retraining of human gait - are lightweight cable-driven leg exoskeleton designs effective? IEEE Trans. Neural. Syst. Rehabil. Eng. 26(4), 847\u2013855 (2018). \n                      https:\/\/doi.org\/10.1109\/TNSRE.2018.2815656","journal-title":"IEEE Trans. Neural. Syst. Rehabil. Eng."},{"key":"7_CR6","doi-asserted-by":"publisher","first-page":"223","DOI":"10.1243\/PIME_PROC_1989_203_043_01","volume":"203","author":"JJ O\u2019Connor","year":"1989","unstructured":"O\u2019Connor, J.J., Shercliff, T.L., Biden, E., Goodfellow, J.W.: The geometry of the knee in the sagittal plane. Proc. Inst. Mech. Eng. H. 203, 223\u2013233 (1989). \n                      https:\/\/doi.org\/10.1243\/PIME_PROC_1989_203_043_01","journal-title":"Proc. Inst. Mech. Eng. H."},{"issue":"8","key":"7_CR7","doi-asserted-by":"publisher","first-page":"677","DOI":"10.1016\/0021-9290(80)90354-1","volume":"13","author":"J Wismans","year":"1980","unstructured":"Wismans, J., Veldpaus, F., Janssen, J., Huson, A., Struben, P.: A threedimensional mathematical model of the knee-joint. J. Biomech. 13(8), 677\u2013685 (1980). \n                      https:\/\/doi.org\/10.1016\/0021-9290(80)90354-1","journal-title":"J. Biomech."},{"key":"7_CR8","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1046\/j.1525-1403.2003.03017.x","volume":"6","author":"S Jezernik","year":"2003","unstructured":"Jezernik, S., Colombo, G., Keller, T., Frueh, H., Morari, M.: Robotic orthosis lokomat: a rehabilitation and research tool. J. Neurol. Neurosur. Psychiatry 6, 108\u2013115 (2003). \n                      https:\/\/doi.org\/10.1046\/j.1525-1403.2003.03017.x","journal-title":"J. Neurol. Neurosur. Psychiatry"},{"key":"7_CR9","doi-asserted-by":"publisher","first-page":"379","DOI":"10.1109\/tnsre.2007.903919","volume":"15","author":"JF Veneman","year":"2007","unstructured":"Veneman, J.F., Kruidhof, R., Hekman, E.E.G., van Asseldonk, E.H.F., van der Kooij, H.: Design and evaluation of the LOPES exoskeleton robot for interactive gait rehabilitation. IEEE Trans. Neural. Syst. Rehabil. Eng. 15, 379\u2013386 (2007). \n                      https:\/\/doi.org\/10.1109\/tnsre.2007.903919","journal-title":"IEEE Trans. Neural. Syst. Rehabil. Eng."},{"key":"7_CR10","doi-asserted-by":"publisher","unstructured":"Zhou, Z., Liao, Y., Wang, C., Wang, Q.: Preliminary evaluation of gait assistance during treadmill walking with a bionic knee exoskeleton. In: Proceedings of the IEEE International Conference on Robotics and Biomimetics, pp. 1173\u20131178 (2016). \n                      https:\/\/doi.org\/10.1109\/ROBIO.2016.7866484","DOI":"10.1109\/ROBIO.2016.7866484"},{"key":"7_CR11","doi-asserted-by":"publisher","unstructured":"Horst, R.W.: A bio-robotic leg orthosis for rehabilitation and mobility enhancement. In: Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, pp. 5030\u20135033 (2009). \n                      https:\/\/doi.org\/10.1109\/IEMBS.2009.5333581","DOI":"10.1109\/IEMBS.2009.5333581"},{"key":"7_CR12","doi-asserted-by":"crossref","unstructured":"Liu, X., Zhou, Z., Wang, Q.: Real-time onboard recognition of gait transitions for a bionic knee exoskeleton in transparent mode. In: Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, pp. 3202\u20133205 (2018)","DOI":"10.1109\/EMBC.2018.8512895"},{"issue":"1","key":"7_CR13","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1016\/S0966-6362(01)00162-X","volume":"15","author":"R Riener","year":"2002","unstructured":"Riener, R., Rabuffetti, M., Frigo, C.: Stair ascent and descent at different inclinations. Gait Posture 15(1), 32\u201344 (2002). \n                      https:\/\/doi.org\/10.1016\/S0966-6362(01)00162-X","journal-title":"Gait Posture"},{"issue":"1","key":"7_CR14","doi-asserted-by":"publisher","first-page":"62","DOI":"10.1016\/j.gaitpost.2012.10.013","volume":"38","author":"G Spyropoulos","year":"2013","unstructured":"Spyropoulos, G., Tsatalas, T., Tsaopoulos, D.E., Sideris, V., Giakas, G.: Biomechanics of sit-to-stand transition after muscle damage. Gait Posture 38(1), 62\u201367 (2013). \n                      https:\/\/doi.org\/10.1016\/j.gaitpost.2012.10.013","journal-title":"Gait Posture"},{"issue":"3","key":"7_CR15","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1016\/S0268-0033(02)00191-2","volume":"18","author":"MKY Mak","year":"2003","unstructured":"Mak, M.K.Y., Levin, O., Mizrahi, J., Hui-Chan, C.W.Y.: Joint torques during sit-to-stand in healthy subjects and people with parkinson\u2019s disease. Clin. Biomech. 18(3), 197\u2013206 (2003). \n                      https:\/\/doi.org\/10.1016\/S0268-0033(02)00191-2","journal-title":"Clin. Biomech."},{"key":"7_CR16","doi-asserted-by":"publisher","DOI":"10.1016\/S0031-9406(10)63713-3","volume-title":"Biomechanics and Motor Control of Human Movement","author":"DA Winter","year":"2009","unstructured":"Winter, D.A.: Biomechanics and Motor Control of Human Movement. Wiley, Hoboken (2009). \n                      https:\/\/doi.org\/10.1016\/S0031-9406(10)63713-3"},{"issue":"4","key":"7_CR17","doi-asserted-by":"publisher","first-page":"80","DOI":"10.1109\/mra.2015.2408791","volume":"22","author":"Q Wang","year":"2015","unstructured":"Wang, Q., Yuan, K., Zhu, J., Wang, L.: Walk the walk: a lightweight active transtibial prosthesis. IEEE Robot. Autom. Mag. 22(4), 80\u201389 (2015). \n                      https:\/\/doi.org\/10.1109\/mra.2015.2408791","journal-title":"IEEE Robot. Autom. Mag."}],"container-title":["Lecture Notes in Computer Science","Intelligent Robotics and Applications"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-030-27526-6_7","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,8,1]],"date-time":"2019-08-01T20:38:33Z","timestamp":1564691913000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-030-27526-6_7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019]]},"ISBN":["9783030275259","9783030275266"],"references-count":17,"URL":"https:\/\/doi.org\/10.1007\/978-3-030-27526-6_7","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"type":"print","value":"0302-9743"},{"type":"electronic","value":"1611-3349"}],"subject":[],"published":{"date-parts":[[2019]]},"assertion":[{"value":"2 August 2019","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}},{"value":"ICIRA","order":1,"name":"conference_acronym","label":"Conference Acronym","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"International Conference on Intelligent Robotics and Applications","order":2,"name":"conference_name","label":"Conference Name","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Shenyang","order":3,"name":"conference_city","label":"Conference City","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"China","order":4,"name":"conference_country","label":"Conference Country","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2019","order":5,"name":"conference_year","label":"Conference Year","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"8 August 2019","order":7,"name":"conference_start_date","label":"Conference Start Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"11 August 2019","order":8,"name":"conference_end_date","label":"Conference End Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"12","order":9,"name":"conference_number","label":"Conference Number","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"icira2019","order":10,"name":"conference_id","label":"Conference ID","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"https:\/\/www.icira2019.org\/","order":11,"name":"conference_url","label":"Conference URL","group":{"name":"ConferenceInfo","label":"Conference Information"}}]}}