{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,6]],"date-time":"2026-03-06T15:31:16Z","timestamp":1772811076010,"version":"3.50.1"},"publisher-location":"Cham","reference-count":22,"publisher":"Springer International Publishing","isbn-type":[{"value":"9783030275372","type":"print"},{"value":"9783030275389","type":"electronic"}],"license":[{"start":{"date-parts":[[2019,1,1]],"date-time":"2019-01-01T00:00:00Z","timestamp":1546300800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019]]},"DOI":"10.1007\/978-3-030-27538-9_37","type":"book-chapter","created":{"date-parts":[[2019,8,2]],"date-time":"2019-08-02T19:02:40Z","timestamp":1564772560000},"page":"433-444","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":16,"title":["Design of a Sensor Insole for Gait Analysis"],"prefix":"10.1007","author":[{"given":"Kamen","family":"Ivanov","sequence":"first","affiliation":[]},{"given":"Zhanyong","family":"Mei","sequence":"additional","affiliation":[]},{"given":"Ludwig","family":"Lubich","sequence":"additional","affiliation":[]},{"given":"Nan","family":"Guo","sequence":"additional","affiliation":[]},{"given":"Deng","family":"Xile","sequence":"additional","affiliation":[]},{"given":"Zhichun","family":"Zhao","sequence":"additional","affiliation":[]},{"given":"Olatunji Mumini","family":"Omisore","sequence":"additional","affiliation":[]},{"given":"Derek","family":"Ho","sequence":"additional","affiliation":[]},{"given":"Lei","family":"Wang","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2019,8,3]]},"reference":[{"key":"37_CR1","doi-asserted-by":"publisher","first-page":"404","DOI":"10.1539\/joh.15-0193-OA","volume":"58","author":"E Ochsmann","year":"2016","unstructured":"Ochsmann, E., Noll, U., Ellegast, R., Hermanns, I., Kraus, T.: Influence of different safety shoes on gait and plantar pressure: a standardized examination of workers in the automotive industry. J. Occup. Health 58, 404\u2013412 (2016)","journal-title":"J. Occup. Health"},{"key":"37_CR2","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.cviu.2018.01.007","volume":"167","author":"P Connor","year":"2018","unstructured":"Connor, P., Ross, A.: Biometric recognition by gait: a survey of modalities and features. Comput. Vis. Image Underst. 167, 1\u201327 (2018)","journal-title":"Comput. Vis. Image Underst."},{"key":"37_CR3","series-title":"Lecture Notes of the Institute for Computer Sciences, Social Informatics and Telecommunications Engineering","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1007\/978-3-319-58877-3_2","volume-title":"Wireless Mobile Communication and Healthcare","author":"K Ivanov","year":"2017","unstructured":"Ivanov, K., Mei, Z., Li, H., Du, W., Wang, L.: A custom base station for collecting and processing data of research-grade motion sensor units. In: Perego, P., Andreoni, G., Rizzo, G. (eds.) MobiHealth 2016. LNICST, vol. 192, pp. 11\u201318. Springer, Cham (2017). \n                      https:\/\/doi.org\/10.1007\/978-3-319-58877-3_2"},{"key":"37_CR4","doi-asserted-by":"publisher","first-page":"537","DOI":"10.1007\/s11517-016-1532-7","volume":"55","author":"Z Mei","year":"2017","unstructured":"Mei, Z., Ivanov, K., Zhao, G., Li, H., Wang, L.: An explorative investigation of functional differences in plantar center of pressure of four foot types using sample entropy method. Med. Biol. Eng. Comput. 55, 537\u2013548 (2017)","journal-title":"Med. Biol. Eng. Comput."},{"key":"37_CR5","doi-asserted-by":"publisher","first-page":"1073","DOI":"10.3390\/s140101073","volume":"14","author":"S Crea","year":"2014","unstructured":"Crea, S., Donati, M., De Rossi, S.M.M., Oddo, C.M., Vitiello, N.: A wireless flexible sensorized insole for gait analysis. Sensors 14, 1073\u20131093 (2014)","journal-title":"Sensors"},{"key":"37_CR6","doi-asserted-by":"publisher","first-page":"9884","DOI":"10.3390\/s120709884","volume":"12","author":"AHA Razak","year":"2012","unstructured":"Razak, A.H.A., Zayegh, A., Begg, R.K., Wahab, Y.: Foot plantar pressure measurement system: a review. Sensors 12, 9884\u20139912 (2012)","journal-title":"Sensors"},{"key":"37_CR7","doi-asserted-by":"publisher","first-page":"786","DOI":"10.1016\/j.jbiomech.2016.01.022","volume":"49","author":"JS Schofield","year":"2016","unstructured":"Schofield, J.S., Evans, K.R., Hebert, J.S., Marasco, P.D., Carey, J.P.: The effect of biomechanical variables on force sensitive resistor error: implications for calibration and improved accuracy. J. Biomech. 49, 786\u2013792 (2016)","journal-title":"J. Biomech."},{"key":"37_CR8","doi-asserted-by":"publisher","first-page":"2108","DOI":"10.3390\/s17092108","volume":"17","author":"L Paredes-Madrid","year":"2017","unstructured":"Paredes-Madrid, L., Palacio, C.A., Matute, A., Parra Vargas, C.A.: Underlying physics of conductive polymer composites and force sensing resistors (FSRs) under static loading conditions. Sensors 17, 2108 (2017)","journal-title":"Sensors"},{"key":"37_CR9","unstructured":"TekScan: FlexiForce Sensors User Manual"},{"key":"37_CR10","unstructured":"Tekscan: FlexiForce Standard Model A301, datasheet"},{"key":"37_CR11","doi-asserted-by":"publisher","first-page":"16589","DOI":"10.3390\/s150716589","volume":"15","author":"I Gonzalez","year":"2015","unstructured":"Gonzalez, I., Fontecha, J., Hervas, R., Bravo, J.: An ambulatory system for gait monitoring based on wireless sensorized insoles. Sensors 15, 16589\u201316613 (2015)","journal-title":"Sensors"},{"key":"37_CR12","doi-asserted-by":"publisher","first-page":"44","DOI":"10.3390\/s19010044","volume":"19","author":"W Lee","year":"2018","unstructured":"Lee, W., Hong, S.-H., Oh, H.-W.: Characterization of elastic polymer-based smart insole and a simple foot plantar pressure visualization method using 16 electrodes. Sensors 19, 44 (2018)","journal-title":"Sensors"},{"key":"37_CR13","doi-asserted-by":"publisher","first-page":"84","DOI":"10.2174\/1874120701408010084","volume":"8","author":"HA Ghaida","year":"2014","unstructured":"Ghaida, H.A., Mottet, S., Goujon, J.-M.: Foot modeling and smart plantar pressure reconstruction from three sensors. Open Biomed. Eng. J. 8, 84\u201392 (2014)","journal-title":"Open Biomed. Eng. J."},{"key":"37_CR14","doi-asserted-by":"publisher","first-page":"48","DOI":"10.3390\/electronics5030048","volume":"5","author":"N Hegde","year":"2016","unstructured":"Hegde, N., Bries, M., Sazonov, E.: A comparative review of footwear-based wearable systems. Electronics 5, 48 (2016)","journal-title":"Electronics"},{"key":"37_CR15","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1109\/TBCAS.2017.2750484","volume":"12","author":"D Tsai","year":"2018","unstructured":"Tsai, D., Yuste, R., Shepard, K.L.: Statistically reconstructed multiplexing for very dense, high-channel-count acquisition systems. IEEE Trans. Biomed. Circuits Syst. 12, 13\u201323 (2018)","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"37_CR16","doi-asserted-by":"crossref","unstructured":"Majewski, C., Perkins, A., Faltz, D., Zhang, F., Zhao, H., Xiao, W.: Design of a 3D printed insole with embedded plantar pressure sensor arrays. Presented at the Proceedings of the 2017 ACM International Joint Conference on Pervasive and Ubiquitous Computing and Proceedings of the 2017 ACM International Symposium on Wearable Computers, Maui, Hawaii (2017)","DOI":"10.1145\/3123024.3123179"},{"key":"37_CR17","unstructured":"Tekscan Inc.: Calibration Quick Start Guide for FlexiForce Sensors. Rev A, 06 October 2008"},{"key":"37_CR18","unstructured":"Interlink Electronics, Inc.: FSR Force Sensing Resistors, Integration Guide, Document part number EIG-10000 Rev. C"},{"key":"37_CR19","doi-asserted-by":"publisher","first-page":"150","DOI":"10.1109\/MCOM.2018.1700339","volume":"56","author":"K Yeh","year":"2018","unstructured":"Yeh, K., Su, C., Chiu, W., Zhou, L.: I walk, therefore i am: continuous user authentication with plantar biometrics. IEEE Commun. Mag. 56, 150\u2013157 (2018)","journal-title":"IEEE Commun. Mag."},{"key":"37_CR20","doi-asserted-by":"crossref","unstructured":"Schneider, O.S., MacLean, K.E., Altun, K., Karuei, I., Wu, M.M.A.: Real-time gait classification for persuasive smartphone apps: structuring the literature and pushing the limits. Presented at the Proceedings of the 2013 International Conference on Intelligent User Interfaces, Santa Monica, California, USA (2013)","DOI":"10.1145\/2449396.2449418"},{"key":"37_CR21","doi-asserted-by":"publisher","first-page":"146","DOI":"10.1016\/j.aap.2018.02.011","volume":"118","author":"Y Wu","year":"2018","unstructured":"Wu, Y., Boyle, L.N., McGehee, D.V.: Evaluating variability in foot to pedal movements using functional principal components analysis. Accid. Anal. Prev. 118, 146\u2013153 (2018)","journal-title":"Accid. Anal. Prev."},{"key":"37_CR22","unstructured":"\u00a9 Neurico company. \n                      https:\/\/neurico.com\n                      \n                    . Accessed 27 Apr 2019"}],"container-title":["Lecture Notes in Computer Science","Intelligent Robotics and Applications"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-030-27538-9_37","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,8,2]],"date-time":"2019-08-02T19:08:56Z","timestamp":1564772936000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-030-27538-9_37"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019]]},"ISBN":["9783030275372","9783030275389"],"references-count":22,"URL":"https:\/\/doi.org\/10.1007\/978-3-030-27538-9_37","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"value":"0302-9743","type":"print"},{"value":"1611-3349","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019]]},"assertion":[{"value":"3 August 2019","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}},{"value":"ICIRA","order":1,"name":"conference_acronym","label":"Conference Acronym","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"International Conference on Intelligent Robotics and Applications","order":2,"name":"conference_name","label":"Conference Name","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Shenyang","order":3,"name":"conference_city","label":"Conference City","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"China","order":4,"name":"conference_country","label":"Conference Country","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2019","order":5,"name":"conference_year","label":"Conference Year","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"8 August 2019","order":7,"name":"conference_start_date","label":"Conference Start Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"11 August 2019","order":8,"name":"conference_end_date","label":"Conference End Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"12","order":9,"name":"conference_number","label":"Conference Number","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"icira2019","order":10,"name":"conference_id","label":"Conference ID","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"https:\/\/www.icira2019.org\/","order":11,"name":"conference_url","label":"Conference URL","group":{"name":"ConferenceInfo","label":"Conference Information"}}]}}