{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,26]],"date-time":"2026-06-26T04:04:07Z","timestamp":1782446647196,"version":"3.54.5"},"publisher-location":"Cham","reference-count":14,"publisher":"Springer International Publishing","isbn-type":[{"value":"9783030324742","type":"print"},{"value":"9783030324759","type":"electronic"}],"license":[{"start":{"date-parts":[[2019,1,1]],"date-time":"2019-01-01T00:00:00Z","timestamp":1546300800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019]]},"DOI":"10.1007\/978-3-030-32475-9_17","type":"book-chapter","created":{"date-parts":[[2019,10,27]],"date-time":"2019-10-27T20:02:24Z","timestamp":1572206544000},"page":"230-241","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Manual Segmentation Errors in Medical Imaging. Proposing a Reliable Gold Standard"],"prefix":"10.1007","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9184-787X","authenticated-orcid":false,"given":"Fernando","family":"Yepes-Calderon","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3832-3270","authenticated-orcid":false,"given":"J.","family":"Gordon McComb","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,10,28]]},"reference":[{"key":"17_CR1","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1118\/1.597064","volume":"20","author":"KT Bae","year":"1993","unstructured":"Bae, K.T., Giger, M.L., Chen, C.-T., Kahn Jr., C.E.: Automatic segmentation of liver structure in ct images. Med. Phys. 20, 71\u201378 (1993)","journal-title":"Med. Phys."},{"key":"17_CR2","doi-asserted-by":"publisher","first-page":"599","DOI":"10.1080\/15428119591016836","volume":"56","author":"DT Dyjack","year":"1995","unstructured":"Dyjack, D.T., Levine, S.P.: Development of an ISO 9000 compatible occupational health standard: defining the issues. Am. Ind. Hyg. Assoc. J. 56, 599\u2013609 (1995)","journal-title":"Am. Ind. Hyg. Assoc. J."},{"key":"17_CR3","doi-asserted-by":"publisher","first-page":"607","DOI":"10.1016\/j.neuroimage.2005.06.061","volume":"28","author":"F Admiraal-Behloul","year":"2005","unstructured":"Admiraal-Behloul, F., et al.: Fully automatic segmentation of white matter hyperintensities in MR images of the elderly. NeuroImage 28, 607\u2013617 (2005)","journal-title":"NeuroImage"},{"key":"17_CR4","doi-asserted-by":"crossref","unstructured":"Fenster, A., Chiu, B.: Evaluation of segmentation algorithms for medical imaging. IEEE EMB, January 2006","DOI":"10.1109\/IEMBS.2005.1616166"},{"key":"17_CR5","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1016\/j.fuel.2014.06.042","volume":"135","author":"D Duca","year":"2014","unstructured":"Duca, D., Riva, G., Foppa, E., Toscano, P.G.: Wood pellet quality with respect to EN 14961\u20132 standard and certifications. Fuel 135, 9\u201314 (2014)","journal-title":"Fuel"},{"key":"17_CR6","doi-asserted-by":"publisher","first-page":"296","DOI":"10.1016\/j.joca.2016.01.540","volume":"24","author":"Y Fukuda","year":"2016","unstructured":"Fukuda, Y., Terada, Y., Yoshioka, H., Yu, H.J., Chang, A.: Comparative study of intra-operator variability in manual and semi-automatic segmentation of knee cartilage. Abstr.\/Osteoarthr. Cartil. 24, 296\u2013297 (2016)","journal-title":"Abstr.\/Osteoarthr. Cartil."},{"key":"17_CR7","doi-asserted-by":"publisher","first-page":"2744","DOI":"10.1016\/j.jclepro.2015.10.023","volume":"112","author":"B Jovanovi\u0107","year":"2016","unstructured":"Jovanovi\u0107, B., Filipovi\u0107, J.: ISO 50001 standard-based energy management maturity model-proposal and validation in industry. J. Clean. Prod. 112, 2744\u20132755 (2016)","journal-title":"J. Clean. Prod."},{"issue":"6","key":"17_CR8","doi-asserted-by":"publisher","first-page":"3013","DOI":"10.1118\/1.4921067","volume":"42","author":"H Kim","year":"2015","unstructured":"Kim, H., et al.: Quantitative evaluation of image segmentation incorporating medical consideration functions. Med. Phys. 42(6), 3013\u20133023 (2015)","journal-title":"Med. Phys."},{"key":"17_CR9","unstructured":"Moeskops, P., Viergever, M.A., Mendrik, A.M., de Vries, L.S., Benders, M.J.N.L., I\u0161gum, I.: Automatic segmentation of MR brain images with a convolutional neural network. Fuel 9\u201314 (2014)"},{"key":"17_CR10","doi-asserted-by":"crossref","unstructured":"Pohle, R., Toennies, K.D.: Segmentation of medical images using adaptive region growing. In: Proceedings of Medical Imaging, vol. 4322, July 2001","DOI":"10.1117\/12.431013"},{"key":"17_CR11","doi-asserted-by":"publisher","first-page":"355","DOI":"10.1016\/j.jcms.2014.12.005","volume":"43","author":"M Rana","year":"2015","unstructured":"Rana, M., et al.: Development and evaluation of an automatic tumor segmentation tool: a comparison between automatic, semi-automatic and manual segmentation of mandibular odontogenic cysts and tumors. J. Cranio-Maxillo-Fac. Surg. 43, 355\u2013359 (2015)","journal-title":"J. Cranio-Maxillo-Fac. Surg."},{"key":"17_CR12","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1016\/j.buildenv.2015.03.035","volume":"92","author":"W Wei","year":"2015","unstructured":"Wei, W., Ramalho, O., Mandin, C.: Indoor air quality requirements in green building certifications. Build. Environ. 92, 10\u201319 (2015)","journal-title":"Build. Environ."},{"key":"17_CR13","doi-asserted-by":"crossref","unstructured":"Yan, P., Kassim, A.A.: Medical image segmentation using minimal path deformable models with implicit shape priors. In: IEEE EMB, October 2006","DOI":"10.1109\/TITB.2006.874199"},{"key":"17_CR14","doi-asserted-by":"publisher","first-page":"427","DOI":"10.1007\/s10877-005-2033-7","volume":"19","author":"J Yao","year":"2005","unstructured":"Yao, J., Warren, S.: Applying the ISO\/IEEE 11073 standards to wearable home health monitoring systems. J. Clin. Monit. Comput. 19, 427\u2013436 (2005)","journal-title":"J. Clin. Monit. Comput."}],"container-title":["Communications in Computer and Information Science","Applied Informatics"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-030-32475-9_17","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,12,28]],"date-time":"2019-12-28T06:11:34Z","timestamp":1577513494000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-030-32475-9_17"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019]]},"ISBN":["9783030324742","9783030324759"],"references-count":14,"URL":"https:\/\/doi.org\/10.1007\/978-3-030-32475-9_17","relation":{},"ISSN":["1865-0929","1865-0937"],"issn-type":[{"value":"1865-0929","type":"print"},{"value":"1865-0937","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019]]},"assertion":[{"value":"28 October 2019","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}},{"value":"ICAI","order":1,"name":"conference_acronym","label":"Conference Acronym","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"International Conference on Applied Informatics","order":2,"name":"conference_name","label":"Conference Name","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Madrid","order":3,"name":"conference_city","label":"Conference City","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Spain","order":4,"name":"conference_country","label":"Conference Country","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2019","order":5,"name":"conference_year","label":"Conference Year","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"7 November 2019","order":7,"name":"conference_start_date","label":"Conference Start Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"9 November 2019","order":8,"name":"conference_end_date","label":"Conference End Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2","order":9,"name":"conference_number","label":"Conference Number","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"icai22019","order":10,"name":"conference_id","label":"Conference ID","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"http:\/\/icai.itiud.org\/","order":11,"name":"conference_url","label":"Conference URL","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Double-blind","order":1,"name":"type","label":"Type","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"Easychair","order":2,"name":"conference_management_system","label":"Conference Management System","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"98","order":3,"name":"number_of_submissions_sent_for_review","label":"Number of Submissions Sent for Review","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"37","order":4,"name":"number_of_full_papers_accepted","label":"Number of Full Papers Accepted","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"1","order":5,"name":"number_of_short_papers_accepted","label":"Number of Short Papers Accepted","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"38% - The value is computed by the equation \"Number of Full Papers Accepted \/ Number of Submissions Sent for Review * 100\" and then rounded to a whole number.","order":6,"name":"acceptance_rate_of_full_papers","label":"Acceptance Rate of Full Papers","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"4","order":7,"name":"average_number_of_reviews_per_paper","label":"Average Number of Reviews per Paper","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"3","order":8,"name":"average_number_of_papers_per_reviewer","label":"Average Number of Papers per Reviewer","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"No","order":9,"name":"external_reviewers_involved","label":"External Reviewers Involved","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}}]}}