{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,3,25]],"date-time":"2025-03-25T19:19:55Z","timestamp":1742930395659,"version":"3.40.3"},"publisher-location":"Cham","reference-count":13,"publisher":"Springer International Publishing","isbn-type":[{"type":"print","value":"9783030370770"},{"type":"electronic","value":"9783030370787"}],"license":[{"start":{"date-parts":[[2019,1,1]],"date-time":"2019-01-01T00:00:00Z","timestamp":1546300800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019]]},"DOI":"10.1007\/978-3-030-37078-7_24","type":"book-chapter","created":{"date-parts":[[2019,12,5]],"date-time":"2019-12-05T00:15:28Z","timestamp":1575504928000},"page":"244-253","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Anesthesia Assessment Based on ICA Permutation Entropy Analysis of Two-Channel EEG Signals"],"prefix":"10.1007","author":[{"given":"Tianning","family":"Li","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Prashanth","family":"Sivakumar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiaohui","family":"Tao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2019,12,5]]},"reference":[{"issue":"4","key":"24_CR1","doi-asserted-by":"publisher","first-page":"630","DOI":"10.1109\/TITB.2011.2155081","volume":"15","author":"T Nguyen-Ky","year":"2011","unstructured":"Nguyen-Ky, T., Wen, P., Li, Y., Gray, R.: Measuring and reflecting depth of anesthesia using wavelet and power spectral density. IEEE Trans. Inf. Technol. Biomed. 15(4), 630\u2013639 (2011)","journal-title":"IEEE Trans. Inf. Technol. Biomed."},{"issue":"4","key":"24_CR2","doi-asserted-by":"publisher","first-page":"793","DOI":"10.1016\/j.atc.2006.08.006","volume":"24","author":"TA Bowdle","year":"2006","unstructured":"Bowdle, T.A.: Depth of anesthesia monitoring. Anesthesiol. Clin. 24(4), 793 (2006)","journal-title":"Anesthesiol. Clin."},{"issue":"6","key":"24_CR3","doi-asserted-by":"publisher","first-page":"1417","DOI":"10.1109\/TITB.2010.2072963","volume":"14","author":"D Chen","year":"2010","unstructured":"Chen, D., Li, D., Xiong, M., Bao, H., Li, X.: GPGPU-aided ensemble empirical-mode decomposition for EEG analysis during anesthesia. IEEE Trans. Inf. Technol. Biomed. 14(6), 1417\u20131427 (2010)","journal-title":"IEEE Trans. Inf. Technol. Biomed."},{"key":"24_CR4","doi-asserted-by":"crossref","unstructured":"Myles, P.S., Leslie, K., McNeil, J., Forbes, A., Chan, M.T.V., B-Aware Trial Group: Bispectral index monitoring to prevent awareness during anaesthesia: the B-Aware randomised controlled trial. Lancet 363(9423), 1757\u20131763 (2004)","DOI":"10.1016\/S0140-6736(04)16300-9"},{"key":"24_CR5","first-page":"712","volume":"5","author":"NN Kumar","year":"2016","unstructured":"Kumar, N.N., Reddy, A.G.: Removal of ECG artifact from EEG data using independent component analysis and S-transform. Int. J. Sci. Eng. Technol. Res. 5, 712\u2013716 (2016)","journal-title":"Int. J. Sci. Eng. Technol. Res."},{"key":"24_CR6","unstructured":"Bibian, S., et al.: Method and apparatus for the estimation of anesthetic depth using wavelet analysis of the electroencephalogram. U.S. Patent 7 373,198 (2008)"},{"issue":"9","key":"24_CR7","doi-asserted-by":"publisher","first-page":"3458","DOI":"10.3390\/e15093458","volume":"15","author":"Q Wei","year":"2013","unstructured":"Wei, Q., et al.: Analysis of EEG via multivariate empirical mode decomposition for depth of anesthesia based on sample entropy. Entropy 15(9), 3458\u20133470 (2013)","journal-title":"Entropy"},{"issue":"10","key":"24_CR8","doi-asserted-by":"publisher","first-page":"2369","DOI":"10.1109\/TBME.2010.2053929","volume":"57","author":"T Nguyen-Ky","year":"2010","unstructured":"Nguyen-Ky, T., Wen, P., Li, Y.: An improved detrended moving-average method for monitoring the depth of anesthesia. IEEE Trans. Biomed. Eng. 57(10), 2369\u20132378 (2010)","journal-title":"IEEE Trans. Biomed. Eng."},{"issue":"5","key":"24_CR9","doi-asserted-by":"publisher","first-page":"1216","DOI":"10.1109\/TBME.2010.2103560","volume":"58","author":"J Kortelainen","year":"2011","unstructured":"Kortelainen, J., V\u00e4yrynen, E., Sepp\u00e4nen, T.: Depth of anesthesia during multidrug infusion: separating the effects of propofol and remifentanil using the spectral features of EEG. IEEE Trans. Biomed. Eng. 58(5), 1216\u20131223 (2011)","journal-title":"IEEE Trans. Biomed. Eng."},{"issue":"6","key":"24_CR10","doi-asserted-by":"publisher","first-page":"1488","DOI":"10.1109\/TBME.2012.2236649","volume":"60","author":"T Nguyen-Ky","year":"2013","unstructured":"Nguyen-Ky, T., Wen, P.P., Li, Y.: Consciousness and depth of anesthesia assessment based on Bayesian analysis of EEG signals. IEEE Trans. Biomed. Eng. 60(6), 1488\u20131498 (2013)","journal-title":"IEEE Trans. Biomed. Eng."},{"issue":"6","key":"24_CR11","doi-asserted-by":"publisher","first-page":"1014","DOI":"10.1097\/ALN.0b013e31818d6c55","volume":"109","author":"D Jordan","year":"2008","unstructured":"Jordan, D., Stockmanns, G., Kochs, E.F., Pilge, S., Schneider, G.: Electroencephalographic order pattern analysis for the separation of consciousness and unconsciousness: an analysis of approximate entropy, permutation entropy, recurrence rate, and phase coupling of order recurrence plots. Anesthesiol.: J. Am. Soc. Anesthesiol. 109(6), 1014\u20131022 (2008)","journal-title":"Anesthesiol.: J. Am. Soc. Anesthesiol."},{"issue":"26","key":"24_CR12","doi-asserted-by":"publisher","first-page":"64","DOI":"10.1109\/MEMB.2007.335582","volume":"2","author":"I Rezek","year":"2007","unstructured":"Rezek, I., Roberts, S.J., Conradt, R.: Increasing the depth of anesthesia assessment. IEEE Eng. Med. Biol. Mag. 2(26), 64\u201373 (2007)","journal-title":"IEEE Eng. Med. Biol. Mag."},{"issue":"2","key":"24_CR13","doi-asserted-by":"publisher","first-page":"431","DOI":"10.1007\/s13246-014-0263-z","volume":"37","author":"T Li","year":"2014","unstructured":"Li, T., Wen, P., Jayamaha, S.: Anaesthetic EEG signal denoise using improved nonlocal mean methods. Australas. Phys. Eng. Sci. Med. 37(2), 431\u2013437 (2014)","journal-title":"Australas. Phys. Eng. Sci. Med."}],"container-title":["Lecture Notes in Computer Science","Brain Informatics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-030-37078-7_24","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,3,13]],"date-time":"2024-03-13T18:59:43Z","timestamp":1710356383000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/978-3-030-37078-7_24"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019]]},"ISBN":["9783030370770","9783030370787"],"references-count":13,"URL":"https:\/\/doi.org\/10.1007\/978-3-030-37078-7_24","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"type":"print","value":"0302-9743"},{"type":"electronic","value":"1611-3349"}],"subject":[],"published":{"date-parts":[[2019]]},"assertion":[{"value":"5 December 2019","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}},{"value":"BI","order":1,"name":"conference_acronym","label":"Conference Acronym","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"International Conference on Brain Informatics","order":2,"name":"conference_name","label":"Conference Name","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Haikou","order":3,"name":"conference_city","label":"Conference City","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"China","order":4,"name":"conference_country","label":"Conference Country","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2019","order":5,"name":"conference_year","label":"Conference Year","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"13 December 2019","order":7,"name":"conference_start_date","label":"Conference Start Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"15 December 2019","order":8,"name":"conference_end_date","label":"Conference End Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"12","order":9,"name":"conference_number","label":"Conference Number","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"brain2019a","order":10,"name":"conference_id","label":"Conference ID","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"http:\/\/wi-consortium.org\/conferences\/bi2019\/index.html","order":11,"name":"conference_url","label":"Conference URL","group":{"name":"ConferenceInfo","label":"Conference Information"}}]}}