{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,3,28]],"date-time":"2025-03-28T04:23:34Z","timestamp":1743135814507,"version":"3.40.3"},"publisher-location":"Cham","reference-count":23,"publisher":"Springer International Publishing","isbn-type":[{"type":"print","value":"9783030869922"},{"type":"electronic","value":"9783030869939"}],"license":[{"start":{"date-parts":[[2021,1,1]],"date-time":"2021-01-01T00:00:00Z","timestamp":1609459200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,1,1]],"date-time":"2021-01-01T00:00:00Z","timestamp":1609459200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2021]]},"DOI":"10.1007\/978-3-030-86993-9_29","type":"book-chapter","created":{"date-parts":[[2021,9,14]],"date-time":"2021-09-14T23:08:06Z","timestamp":1631660886000},"page":"310-320","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Frequency Bands Selection for Seizure Classification and Forecasting Using NLP, Random Forest and SVM Models"],"prefix":"10.1007","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5423-1512","authenticated-orcid":false,"given":"Ziwei","family":"Wang","sequence":"first","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0713-6261","authenticated-orcid":false,"given":"Paolo","family":"Mengoni","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2021,9,15]]},"reference":[{"issue":"3","key":"29_CR1","doi-asserted-by":"publisher","first-page":"241","DOI":"10.1088\/0967-3334\/27\/3\/003","volume":"27","author":"D Ab\u00e1solo","year":"2006","unstructured":"Ab\u00e1solo, D., Hornero, R., Espino, P., Alvarez, D., Poza, J.: Entropy analysis of the EEG background activity in Alzheimer\u2019s disease patients. Physiol. Meas. 27(3), 241 (2006)","journal-title":"Physiol. Meas."},{"issue":"1","key":"29_CR2","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1016\/S1388-2457(02)00322-X","volume":"114","author":"J Altenburg","year":"2003","unstructured":"Altenburg, J., Vermeulen, R.J., Strijers, R.L., Fetter, W.P., Stam, C.J.: Seizure detection in the neonatal EEG with synchronization likelihood. Clin. Neurophysiol. 114(1), 50\u201355 (2003)","journal-title":"Clin. Neurophysiol."},{"issue":"2","key":"29_CR3","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1016\/j.ijep.2015.04.001","volume":"2","author":"JM Chung","year":"2015","unstructured":"Chung, J.M., et al.: Utility of invasive ictal EEG recordings in pre-surgical evaluation of patients with medically refractory temporal lobe epilepsy and normal MRI. Int. J. Epilepsy 2(2), 66\u201371 (2015)","journal-title":"Int. J. Epilepsy"},{"issue":"1\u20132","key":"29_CR4","doi-asserted-by":"publisher","first-page":"116","DOI":"10.1016\/j.eplepsyres.2011.05.011","volume":"96","author":"KA Davis","year":"2011","unstructured":"Davis, K.A., et al.: A novel implanted device to wirelessly record and analyze continuous intracranial canine EEG. Epilepsy Res. 96(1\u20132), 116\u2013122 (2011)","journal-title":"Epilepsy Res."},{"key":"29_CR5","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1111\/j.1528-1167.2007.00992.x","volume":"48","author":"JA French","year":"2007","unstructured":"French, J.A.: Refractory epilepsy: clinical overview. Epilepsia 48, 3\u20137 (2007)","journal-title":"Epilepsia"},{"key":"29_CR6","unstructured":"Gardner, A.B., Krieger, A.M., Vachtsevanos, G., Litt, B., Kaelbing, L.P.: One-class novelty detection for seizure analysis from intracranial EEG. J. Mach. Learn. Res. 7(6) (2006)"},{"issue":"5","key":"29_CR7","doi-asserted-by":"publisher","first-page":"530","DOI":"10.1016\/0013-4694(82)90038-4","volume":"54","author":"J Gotman","year":"1982","unstructured":"Gotman, J.: Automatic recognition of epileptic seizures in the EEG. Electroencephalogr. Clin. Neurophysiol. 54(5), 530\u2013540 (1982)","journal-title":"Electroencephalogr. Clin. Neurophysiol."},{"key":"29_CR8","unstructured":"Kaggle: UPenn and mayo clinic\u2019s seizure detection challenge (2014). https:\/\/www.kaggle.com\/c\/seizure-detection"},{"key":"29_CR9","doi-asserted-by":"crossref","unstructured":"Lopez, S., Gross, A., Yang, S., Golmohammadi, M., Obeid, I., Picone, J.: An analysis of two common reference points for EEGs. In: 2016 IEEE Signal Processing in Medicine and Biology Symposium (SPMB), pp. 1\u20135. IEEE (2016)","DOI":"10.1109\/SPMB.2016.7846854"},{"key":"29_CR10","doi-asserted-by":"publisher","first-page":"204","DOI":"10.1016\/j.neucom.2017.02.053","volume":"241","author":"M Mursalin","year":"2017","unstructured":"Mursalin, M., Zhang, Y., Chen, Y., Chawla, N.V.: Automated epileptic seizure detection using improved correlation-based feature selection with random forest classifier. Neurocomputing 241, 204\u2013214 (2017)","journal-title":"Neurocomputing"},{"issue":"9","key":"29_CR11","doi-asserted-by":"publisher","first-page":"601","DOI":"10.1016\/S1350-4533(99)00092-2","volume":"21","author":"S Nishida","year":"1999","unstructured":"Nishida, S., Nakamura, M., Ikeda, A., Shibasaki, H.: Signal separation of background EEG and spike by using morphological filter. Med. Eng. Phys. 21(9), 601\u2013608 (1999)","journal-title":"Med. Eng. Phys."},{"key":"29_CR12","doi-asserted-by":"publisher","first-page":"196","DOI":"10.3389\/fnins.2016.00196","volume":"10","author":"I Obeid","year":"2016","unstructured":"Obeid, I., Picone, J.: The temple university hospital EEG data corpus. Front. Neurosci. 10, 196 (2016)","journal-title":"Front. Neurosci."},{"key":"29_CR13","doi-asserted-by":"crossref","unstructured":"Raghunathan, S., Gupta, S.K., Ward, M.P., Worth, R.M., Roy, K., Irazoqui, P.P.: The design and hardware implementation of a low-power real-time seizure detection algorithm. J. Neural Eng. 6(5), 056005 (2009)","DOI":"10.1088\/1741-2560\/6\/5\/056005"},{"key":"29_CR14","doi-asserted-by":"crossref","unstructured":"Roy, S., Asif, U., Tang, J., Harrer, S.: Seizure type classification using EEG signals and machine learning: setting a benchmark. In: 2020 IEEE Signal Processing in Medicine and Biology Symposium (SPMB), pp. 1\u20136. IEEE (2020)","DOI":"10.1109\/SPMB50085.2020.9353642"},{"issue":"5","key":"29_CR15","doi-asserted-by":"publisher","first-page":"437","DOI":"10.1016\/j.seizure.2007.12.009","volume":"17","author":"E Santiago-Rodr\u00edguez","year":"2008","unstructured":"Santiago-Rodr\u00edguez, E., Harmony, T., C\u00e1rdenas-Morales, L., Hern\u00e1ndez, A., Fern\u00e1ndez-Bouzas, A.: Analysis of background EEG activity in patients with juvenile myoclonic epilepsy. Seizure 17(5), 437\u2013445 (2008)","journal-title":"Seizure"},{"key":"29_CR16","doi-asserted-by":"publisher","first-page":"83","DOI":"10.3389\/fninf.2018.00083","volume":"12","author":"V Shah","year":"2018","unstructured":"Shah, V.: The temple university hospital seizure detection corpus. Front. Neuroinform. 12, 83 (2018)","journal-title":"Front. Neuroinform."},{"key":"29_CR17","unstructured":"Shoeb, A.H., Guttag, J.V.: Application of machine learning to epileptic seizure detection. In: Proceedings of the 27th International Conference on Machine Learning (ICML 2010), pp. 975\u2013982 (2010)"},{"key":"29_CR18","doi-asserted-by":"crossref","unstructured":"Sirven, J.I.: Epilepsy: a spectrum disorder. Cold Spring Harbor Pers. Med. 5(9), a022848 (2015)","DOI":"10.1101\/cshperspect.a022848"},{"key":"29_CR19","doi-asserted-by":"crossref","unstructured":"Stafstrom, C.E., Carmant, L.: Seizures and epilepsy: an overview for neuroscientists. Cold Spring Harbor Persp. Med. 5(6), a022426 (2015)","DOI":"10.1101\/cshperspect.a022426"},{"issue":"3","key":"29_CR20","doi-asserted-by":"publisher","first-page":"235","DOI":"10.1097\/WNP.0000000000000159","volume":"32","author":"JB Wagenaar","year":"2015","unstructured":"Wagenaar, J.B., Worrell, G.A., Ives, Z., D\u00fcmpelmann, M., Litt, B., Schulze-Bonhage, A.: Collaborating and sharing data in epilepsy research. J. Clin. Neurophysiol. Official Publ. Am. Electroencephalogr. Society 32(3), 235 (2015)","journal-title":"J. Clin. Neurophysiol. Official Publ. Am. Electroencephalogr. Society"},{"issue":"4","key":"29_CR21","doi-asserted-by":"publisher","first-page":"530","DOI":"10.1007\/s10548-019-00707-x","volume":"32","author":"D Yao","year":"2019","unstructured":"Yao, D., Qin, Y., Hu, S., Dong, L., Vega, M.L.B., Sosa, P.A.V.: Which reference should we use for EEG and ERP practice? Brain Topogr. 32(4), 530\u2013549 (2019)","journal-title":"Brain Topogr."},{"issue":"2","key":"29_CR22","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1007\/s40708-016-0044-4","volume":"3","author":"EI Zacharaki","year":"2016","unstructured":"Zacharaki, E.I., Mporas, I., Garganis, K., Megalooikonomou, V.: Spike pattern recognition by supervised classification in low dimensional embedding space. Brain Inform. 3(2), 73\u201383 (2016). https:\/\/doi.org\/10.1007\/s40708-016-0044-4","journal-title":"Brain Inform."},{"key":"29_CR23","doi-asserted-by":"publisher","first-page":"95","DOI":"10.3389\/fninf.2018.00095","volume":"12","author":"M Zhou","year":"2018","unstructured":"Zhou, M., et al.: Epileptic seizure detection based on EEG signals and CNN. Front. Neuroinform. 12, 95 (2018)","journal-title":"Front. Neuroinform."}],"container-title":["Lecture Notes in Computer Science","Brain Informatics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-030-86993-9_29","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,9,14]],"date-time":"2021-09-14T23:45:16Z","timestamp":1631663116000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/978-3-030-86993-9_29"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021]]},"ISBN":["9783030869922","9783030869939"],"references-count":23,"URL":"https:\/\/doi.org\/10.1007\/978-3-030-86993-9_29","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"type":"print","value":"0302-9743"},{"type":"electronic","value":"1611-3349"}],"subject":[],"published":{"date-parts":[[2021]]},"assertion":[{"value":"15 September 2021","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}},{"value":"BI","order":1,"name":"conference_acronym","label":"Conference Acronym","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"International Conference on Brain Informatics","order":2,"name":"conference_name","label":"Conference Name","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2021","order":5,"name":"conference_year","label":"Conference Year","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"17 September 2021","order":7,"name":"conference_start_date","label":"Conference Start Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"19 September 2021","order":8,"name":"conference_end_date","label":"Conference End Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"14","order":9,"name":"conference_number","label":"Conference Number","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"brain2021","order":10,"name":"conference_id","label":"Conference ID","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"https:\/\/bi2021.org\/","order":11,"name":"conference_url","label":"Conference URL","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Single-blind","order":1,"name":"type","label":"Type","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"easychair","order":2,"name":"conference_management_system","label":"Conference Management System","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"90","order":3,"name":"number_of_submissions_sent_for_review","label":"Number of Submissions Sent for Review","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"49","order":4,"name":"number_of_full_papers_accepted","label":"Number of Full Papers Accepted","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"2","order":5,"name":"number_of_short_papers_accepted","label":"Number of Short Papers Accepted","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"54% - The value is computed by the equation \"Number of Full Papers Accepted \/ Number of Submissions Sent for Review * 100\" and then rounded to a whole number.","order":6,"name":"acceptance_rate_of_full_papers","label":"Acceptance Rate of Full Papers","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"3","order":7,"name":"average_number_of_reviews_per_paper","label":"Average Number of Reviews per Paper","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"4","order":8,"name":"average_number_of_papers_per_reviewer","label":"Average Number of Papers per Reviewer","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"Yes","order":9,"name":"external_reviewers_involved","label":"External Reviewers Involved","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}}]}}