{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,3,26]],"date-time":"2025-03-26T04:16:02Z","timestamp":1742962562275,"version":"3.40.3"},"publisher-location":"Cham","reference-count":15,"publisher":"Springer International Publishing","isbn-type":[{"type":"print","value":"9783030869991"},{"type":"electronic","value":"9783030870003"}],"license":[{"start":{"date-parts":[[2021,1,1]],"date-time":"2021-01-01T00:00:00Z","timestamp":1609459200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,1,1]],"date-time":"2021-01-01T00:00:00Z","timestamp":1609459200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2021]]},"DOI":"10.1007\/978-3-030-87000-3_11","type":"book-chapter","created":{"date-parts":[[2021,9,21]],"date-time":"2021-09-21T02:17:10Z","timestamp":1632190630000},"page":"101-108","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Peripapillary Atrophy Segmentation with Boundary Guidance"],"prefix":"10.1007","author":[{"given":"Mengxuan","family":"Li","sequence":"first","affiliation":[]},{"given":"He","family":"Zhao","sequence":"additional","affiliation":[]},{"given":"Jie","family":"Xu","sequence":"additional","affiliation":[]},{"given":"Huiqi","family":"Li","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2021,9,21]]},"reference":[{"issue":"3","key":"11_CR1","doi-asserted-by":"publisher","first-page":"531","DOI":"10.1016\/j.ophtha.2010.07.013","volume":"118","author":"V Manjunath","year":"2011","unstructured":"Manjunath, V., Shah, H., Fujimoto, J.G., Duker, J.S.: Analysis of peripapillary atrophy using spectral domain optical coherence tomography. Ophthalmology 118(3), 531\u2013536 (2011)","journal-title":"Ophthalmology"},{"issue":"6","key":"11_CR2","doi-asserted-by":"publisher","first-page":"587","DOI":"10.1007\/BF02169209","volume":"226","author":"JB Jonas","year":"1988","unstructured":"Jonas, J.B., Gusek, G.C., Naumann, G.O.H.: Optic disk morphometry in high myopia. Graefe\u2019s Arch. Clin. Exp. Ophthalmol. 226(6), 587\u2013590 (1988)","journal-title":"Graefe\u2019s Arch. Clin. Exp. Ophthalmol."},{"key":"11_CR3","doi-asserted-by":"crossref","unstructured":"Lu, C.K., Tang, T.B., Alan, F.M., Lauda, A., Dhillon, B.: Automatic parapapillary atrophy shape detection and quantification in colour fundus images. In: 2010 Biomedical Circuits and Systems Conference (BioCAS), pp. 86\u201389. Paphos (2010)","DOI":"10.1109\/BIOCAS.2010.5709577"},{"issue":"1","key":"11_CR4","first-page":"22","volume":"2","author":"DD Patil","year":"2013","unstructured":"Patil, D.D., Deore, S.G.: Medical image segmentation: a review. Int. J. Comput. Sci. Mob. Comput. 2(1), 22\u201327 (2013)","journal-title":"Int. J. Comput. Sci. Mob. Comput."},{"issue":"8","key":"11_CR5","first-page":"54","volume":"1","author":"HP Narkhede","year":"2013","unstructured":"Narkhede, H.P.: Review of image segmentation techniques. Int. J. Sci. Modern Eng. 1(8), 54\u201361 (2013)","journal-title":"Int. J. Sci. Modern Eng."},{"key":"11_CR6","doi-asserted-by":"crossref","unstructured":"Ronneberger, O., Fischer, P., Brox, T.: U-Net: convolutional networks for biomedical image segmentation. In: International Conference on Medical Image Computing and Computer-Assisted Intervention, pp. 234\u2013241. Springer, Cham (2015)","DOI":"10.1007\/978-3-319-24574-4_28"},{"issue":"12","key":"11_CR7","doi-asserted-by":"publisher","first-page":"2481","DOI":"10.1109\/TPAMI.2016.2644615","volume":"39","author":"V Badrinarayanan","year":"2017","unstructured":"Badrinarayanan, V., Kendal, A., Cipolla, R.: SegNet: a deep convolutional encoder-decoder architecture for image segmentation. IEEE Trans. Pattern Anal. Mach. Intell. 39(12), 2481\u20132495 (2017)","journal-title":"IEEE Trans. Pattern Anal. Mach. Intell."},{"issue":"6","key":"11_CR8","doi-asserted-by":"publisher","first-page":"1192","DOI":"10.1109\/TMI.2011.2106509","volume":"30","author":"GD Joshi","year":"2011","unstructured":"Joshi, G.D., Sivaswamy, J., Krishnadas, S.R.: Optic disk and cup segmentation from monocular color retinal images for glaucoma assessment. IEEE Trans. Med. Imag. 30(6), 1192\u20131205 (2011)","journal-title":"IEEE Trans. Med. Imag."},{"issue":"4","key":"11_CR9","doi-asserted-by":"publisher","first-page":"644","DOI":"10.1109\/TITB.2012.2198668","volume":"16","author":"H Yu","year":"2012","unstructured":"Yu, H., et al.: Fast localization and segmentation of optic disk in retinal images using directional matched filtering and level sets. IEEE Trans. Inform. Technol. Biomed. 16(4), 644\u2013657 (2012)","journal-title":"IEEE Trans. Inform. Technol. Biomed."},{"key":"11_CR10","doi-asserted-by":"publisher","first-page":"483","DOI":"10.1016\/j.bspc.2016.09.009","volume":"31","author":"S Bharkad","year":"2017","unstructured":"Bharkad, S.: Automatic segmentation of optic disk in retinal images. Biomed. Signal Process. Control 31, 483\u2013498 (2017)","journal-title":"Biomed. Signal Process. Control"},{"key":"11_CR11","doi-asserted-by":"publisher","first-page":"140","DOI":"10.1007\/978-3-319-46723-8_17","volume-title":"Medical Image Computing and Computer-Assisted Intervention \u2013 MICCAI 2016","author":"K-K Maninis","year":"2016","unstructured":"Maninis, K.-K., Pont-Tuset, J., Arbel\u00e1ez, P., Van Gool, L.: Deep Retinal Image Understanding. In: Ourselin, S., Joskowicz, L., Sabuncu, M.R., Unal, G., Wells, W. (eds.) Medical Image Computing and Computer-Assisted Intervention \u2013 MICCAI 2016, pp. 140\u2013148. Springer International Publishing, Cham (2016). https:\/\/doi.org\/10.1007\/978-3-319-46723-8_17"},{"key":"11_CR12","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1016\/j.bspc.2019.01.022","volume":"51","author":"L Wang","year":"2019","unstructured":"Wang, L., Liu, H., Lu, Y., Chen, H., Zhang, J., Pu, J.: A coarse-to-fine deep learning framework for optic disc segmentation in fundus images. Biomed. Signal Process. Control 51, 82\u201389 (2019)","journal-title":"Biomed. Signal Process. Control"},{"key":"11_CR13","doi-asserted-by":"publisher","first-page":"105090","DOI":"10.1016\/j.cmpb.2019.105090","volume":"183","author":"H Li","year":"2020","unstructured":"Li, H., Li, H., Kang, J., Feng, Y., Xu, J.: Automatic detection of parapapillary atrophy and its association with children myopia. Comput. Methods Programs Biomed. 183, 105090 (2020)","journal-title":"Comput. Methods Programs Biomed."},{"key":"11_CR14","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.asoc.2019.105890","volume":"86","author":"Y Chai","year":"2020","unstructured":"Chai, Y., Liu, H., Xu, J.: A new convolutional neural network model for peripapillary atrophy area segmentation from retinal fundus images. Appl. Soft Comput. J. 86, 1\u201311 (2020)","journal-title":"Appl. Soft Comput. J."},{"key":"11_CR15","doi-asserted-by":"crossref","unstructured":"Li, H., et al.: Automatic location of optic disk in retinal images. In: Proceedings 2001 International Conference on Image Processing, vol. 2, pp. 837\u2013840 (2001)","DOI":"10.1109\/ICIP.2001.958624"}],"container-title":["Lecture Notes in Computer Science","Ophthalmic Medical Image Analysis"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-030-87000-3_11","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,9,8]],"date-time":"2024-09-08T16:28:46Z","timestamp":1725812926000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/978-3-030-87000-3_11"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021]]},"ISBN":["9783030869991","9783030870003"],"references-count":15,"URL":"https:\/\/doi.org\/10.1007\/978-3-030-87000-3_11","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"type":"print","value":"0302-9743"},{"type":"electronic","value":"1611-3349"}],"subject":[],"published":{"date-parts":[[2021]]},"assertion":[{"value":"21 September 2021","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}},{"value":"OMIA","order":1,"name":"conference_acronym","label":"Conference Acronym","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"International Workshop on Ophthalmic Medical Image Analysis","order":2,"name":"conference_name","label":"Conference Name","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Strasbourg","order":3,"name":"conference_city","label":"Conference City","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"France","order":4,"name":"conference_country","label":"Conference Country","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2021","order":5,"name":"conference_year","label":"Conference Year","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"27 September 2021","order":7,"name":"conference_start_date","label":"Conference Start Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"27 September 2021","order":8,"name":"conference_end_date","label":"Conference End Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"8","order":9,"name":"conference_number","label":"Conference Number","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"omia2021","order":10,"name":"conference_id","label":"Conference ID","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"https:\/\/sites.google.com\/view\/omia8\/","order":11,"name":"conference_url","label":"Conference URL","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Double-blind","order":1,"name":"type","label":"Type","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"CMT System","order":2,"name":"conference_management_system","label":"Conference Management System","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"31","order":3,"name":"number_of_submissions_sent_for_review","label":"Number of Submissions Sent for Review","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"20","order":4,"name":"number_of_full_papers_accepted","label":"Number of Full Papers Accepted","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"0","order":5,"name":"number_of_short_papers_accepted","label":"Number of Short Papers Accepted","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"65% - The value is computed by the equation \"Number of Full Papers Accepted \/ Number of Submissions Sent for Review * 100\" and then rounded to a whole number.","order":6,"name":"acceptance_rate_of_full_papers","label":"Acceptance Rate of Full Papers","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"3","order":7,"name":"average_number_of_reviews_per_paper","label":"Average Number of Reviews per Paper","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"3","order":8,"name":"average_number_of_papers_per_reviewer","label":"Average Number of Papers per Reviewer","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"Yes","order":9,"name":"external_reviewers_involved","label":"External Reviewers Involved","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"The workshop was held virtually.","order":10,"name":"additional_info_on_review_process","label":"Additional Info on Review Process","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}}]}}