{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,18]],"date-time":"2025-11-18T12:25:53Z","timestamp":1763468753809,"version":"3.40.3"},"publisher-location":"Cham","reference-count":20,"publisher":"Springer International Publishing","isbn-type":[{"type":"print","value":"9783030890940"},{"type":"electronic","value":"9783030890957"}],"license":[{"start":{"date-parts":[[2021,1,1]],"date-time":"2021-01-01T00:00:00Z","timestamp":1609459200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,1,1]],"date-time":"2021-01-01T00:00:00Z","timestamp":1609459200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2021]]},"DOI":"10.1007\/978-3-030-89095-7_57","type":"book-chapter","created":{"date-parts":[[2021,10,19]],"date-time":"2021-10-19T05:01:04Z","timestamp":1634619664000},"page":"597-607","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Design and Optimization of the New Cable-Driven Ankle Rehabilitation Equipment"],"prefix":"10.1007","author":[{"given":"Ye","family":"Huo","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jinhao","family":"Duan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhufeng","family":"Shao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hanqing","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chunjiao","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,10,19]]},"reference":[{"key":"57_CR1","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/1743-0003-4-2","volume":"4","author":"H Schmidt","year":"2007","unstructured":"Schmidt, H., Werner, C., Bernhardt, R., Hesse, S., Kruger, J.: Gait rehabilitation machines based on programmable footplates. J. NeuroEng. Rehabil. 4, 1\u20137 (2007)","journal-title":"J. NeuroEng. Rehabil."},{"key":"57_CR2","doi-asserted-by":"publisher","first-page":"613","DOI":"10.1682\/JRRD.2011.08.0142","volume":"49","author":"S Hesse","year":"2012","unstructured":"Hesse, S., Tomelleri CzBardeleben, A., Werner, C., Waldner, A.: Robot-assisted practice of gait and stair climbing in nonambulatory stroke patients. J. Rehabil. Res. Dev. 49, 613\u2013622 (2012)","journal-title":"J. Rehabil. Res. Dev."},{"key":"57_CR3","doi-asserted-by":"crossref","unstructured":"Wang, Z., Cui, L., et al.: Modeling analysis and structural design of human lower limb rehabilitation robot (2018)","DOI":"10.1051\/matecconf\/201823202032"},{"key":"57_CR4","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1186\/1743-0003-7-43","volume":"7","author":"A Duschau-Wicke","year":"2010","unstructured":"Duschau-Wicke, A., Caprez, A., Riener, R.: Patient-cooperative control increases active participation of individuals with SCI during robot-aided gait training. J. NeuroEng. Rehabil. 7, 13 (2010)","journal-title":"J. NeuroEng. Rehabil."},{"issue":"3","key":"57_CR5","doi-asserted-by":"publisher","first-page":"379","DOI":"10.1109\/TNSRE.2007.903919","volume":"15","author":"J Veneman","year":"2007","unstructured":"Veneman, J., Kruidhof, R., Hekman, E., Ekkelenkamp, R., Van Asseldonk, E., van der Kooij, H.: Design and evaluation of the LOPES exoskeleton robot for interactive gait rehabilitation. IEEE Trans. Neural Syst. Rehabil. Eng. 15(3), 379\u2013386 (2007)","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"57_CR6","doi-asserted-by":"crossref","unstructured":"Van Asseldonk, E.H.F., Ekkelenkamp, R., Veneman, J.F.Z., Van der Helm, F.C.T., van der Kooij, H.: Selective control of a subtask of walking in a robotic gait trainer(LOPES). In: 2007 IEEE 10th International Conference on Rehabilitation Robotics, vols. 1 and 2, pp. 841\u2013848 (2007)","DOI":"10.1109\/ICORR.2007.4428522"},{"issue":"5-6","key":"57_CR7","doi-asserted-by":"publisher","first-page":"561","DOI":"10.1177\/0278364906065505","volume":"25","author":"H Kazerooni","year":"2006","unstructured":"Kazerooni, H., Steger, R., Huang, L.: Hybrid control of the Berkeley Lower Extremity Exoskeleton (BLEEX). Int. J. Robot. Res. 25(5\u20136), 561\u2013573 (2006)","journal-title":"Int. J. Robot. Res."},{"key":"57_CR8","unstructured":"Schmidt, H.: Hapticwalker-a novel haptic device for walking simulation. In: Proceedings of EuroHaptics, Tokyo, Japan, pp. 66\u201367 (2004)"},{"issue":"9","key":"57_CR9","doi-asserted-by":"publisher","first-page":"1216","DOI":"10.1177\/0278364909104221","volume":"28","author":"JA Saglia","year":"2009","unstructured":"Saglia, J.A., Tsagarakis, N.G., Dai, J.S., Caldwell, D.G.: A high-performance redundantly actuated parallel mechanism for ankle rehabilitation. Int. J. Robot. Res. 28(9), 1216\u20131227 (2009)","journal-title":"Int. J. Robot. Res."},{"key":"57_CR10","doi-asserted-by":"crossref","unstructured":"Wang, C., Fang, Y., Guo. S., et al.: Design and kinematical performance analysis of a 3-rus\/rrr redundantly actuated parallel mechanism for ankle rehabilitation. J. Mech. Robot. 5, 041003 (2013)","DOI":"10.1115\/1.4024736"},{"key":"57_CR11","unstructured":"Jamwal, P.K., Aw, K.C., Xie, S.Q., Tsoi, Y.H.: Multi-criteria optimal design of cable driven ankle rehabilitation robot. In: Mobile Robots-State of the Art in Land, Sea, Air, and Collaborative Missions. INTECH Open Access Publisher, London (2009)"},{"key":"57_CR12","doi-asserted-by":"publisher","first-page":"53","DOI":"10.17706\/IJCEE.2018.10.1.53-61","volume":"10","author":"MN Shahrol","year":"2018","unstructured":"Shahrol, M.N., Basah, S.N., Basaruddin, K.S., Ahmad, W.K.W., Ahmad, S.A.: Modelling of a Cable-driven ankle rehabilitation robot. J. Telecommun. Electron. Comput. Eng. 10, 53\u201359 (2018)","journal-title":"J. Telecommun. Electron. Comput. Eng."},{"issue":"3","key":"57_CR13","doi-asserted-by":"publisher","first-page":"48","DOI":"10.3390\/machines8030048","volume":"8","author":"M Russo","year":"2020","unstructured":"Russo, M., Ceccarelli, M.: Analysis of a wearable robotic system for ankle rehabilitation. Machines 8(3), 48 (2020)","journal-title":"Machines"},{"issue":"3","key":"57_CR14","doi-asserted-by":"publisher","first-page":"434","DOI":"10.1109\/TRO.2006.870638","volume":"22","author":"M Gouttefarde","year":"2006","unstructured":"Gouttefarde, M., Gosselin, C.: Analysis of the wrench-closure workspace of planar parallel cable-driven mechanisms. IEEE Trans. Rob. 22(3), 434\u2013445 (2006)","journal-title":"IEEE Trans. Rob."},{"issue":"6","key":"57_CR15","doi-asserted-by":"publisher","first-page":"680","DOI":"10.1080\/15397734.2019.1615503","volume":"47","author":"H Quintero-Riaza","year":"2019","unstructured":"Quintero-Riaza, H., Mej\u00eda-Calder\u00f3n, L., D\u00edaz-Rodr\u00edguez, M.: Synthesis of planar parallel manipulators including dexterity, force transmission and stiffness index. Mech. Based Design Struct. Mach. 47(6), 680\u2013702 (2019)","journal-title":"Mech. Based Design Struct. Mach."},{"key":"57_CR16","doi-asserted-by":"publisher","first-page":"691","DOI":"10.1007\/978-3-319-61276-8_73","volume-title":"Advances in Service and Industrial Robotics","author":"H Lamine","year":"2018","unstructured":"Lamine, H., Laribi, M., Bennour, S., Romdhane, L., Zeghloul, S.: Structure optimization of the cable driven legs trainer. In: Ferraresi, C., Quaglia, G. (eds.) Advances in Service and Industrial Robotics, pp. 691\u2013698. Springer International Publishing, Cham (2018). https:\/\/doi.org\/10.1007\/978-3-319-61276-8_73"},{"issue":"2","key":"57_CR17","doi-asserted-by":"publisher","first-page":"180","DOI":"10.1016\/j.rcim.2009.07.002","volume":"26","author":"Z Gao","year":"2010","unstructured":"Gao, Z., Zhang, D., Ge, Y.: Design optimization of a spatial six degree-of-freedom parallel manipulator based on artificial intelligence approaches. Robot. Comput.-Integr. Manuf. 26(2), 180\u2013189 (2010)","journal-title":"Robot. Comput.-Integr. Manuf."},{"issue":"9","key":"57_CR18","doi-asserted-by":"publisher","first-page":"1210","DOI":"10.1016\/j.mechmachtheory.2006.08.002","volume":"42","author":"XJ Liu","year":"2007","unstructured":"Liu, X.J., Wang, J.S.: A new methodology for optimal kinematic design of parallel mechanisms. Mech. Mach. Theory 42(9), 1210\u20131224 (2007)","journal-title":"Mech. Mach. Theory"},{"issue":"1","key":"57_CR19","doi-asserted-by":"publisher","first-page":"20","DOI":"10.3901\/CJME.2014.0929.155","volume":"28","author":"ZF Shao","year":"2015","unstructured":"Shao, Z.F., Tamg, X.Q., Wang, L.P., et al.: Atlas based kinematic optimum design of the stewart parallel manipulator. Chin. J. Mech. Eng. 28(1), 20\u201328 (2015)","journal-title":"Chin. J. Mech. Eng."},{"key":"57_CR20","first-page":"232","volume":"30","author":"CL Brockett","year":"2016","unstructured":"Brockett, C.L., Chapman, G.J.: Biomechanics of the ankle. Orthop. Trauma 30, 232\u2013238 (2016)","journal-title":"Trauma"}],"container-title":["Lecture Notes in Computer Science","Intelligent Robotics and Applications"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-030-89095-7_57","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,10,19]],"date-time":"2021-10-19T05:44:22Z","timestamp":1634622262000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/978-3-030-89095-7_57"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021]]},"ISBN":["9783030890940","9783030890957"],"references-count":20,"URL":"https:\/\/doi.org\/10.1007\/978-3-030-89095-7_57","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"type":"print","value":"0302-9743"},{"type":"electronic","value":"1611-3349"}],"subject":[],"published":{"date-parts":[[2021]]},"assertion":[{"value":"19 October 2021","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}},{"value":"ICIRA","order":1,"name":"conference_acronym","label":"Conference Acronym","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"International Conference on Intelligent Robotics and Applications","order":2,"name":"conference_name","label":"Conference Name","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Yantai","order":3,"name":"conference_city","label":"Conference City","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"China","order":4,"name":"conference_country","label":"Conference Country","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2021","order":5,"name":"conference_year","label":"Conference Year","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"22 October 2021","order":7,"name":"conference_start_date","label":"Conference Start Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"25 October 2021","order":8,"name":"conference_end_date","label":"Conference End Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"14","order":9,"name":"conference_number","label":"Conference Number","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"icira2021","order":10,"name":"conference_id","label":"Conference ID","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"https:\/\/www.icira2021.org\/","order":11,"name":"conference_url","label":"Conference URL","group":{"name":"ConferenceInfo","label":"Conference Information"}}]}}