{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,27]],"date-time":"2026-01-27T23:42:08Z","timestamp":1769557328006,"version":"3.49.0"},"publisher-location":"Cham","reference-count":12,"publisher":"Springer International Publishing","isbn-type":[{"value":"9783031062483","type":"print"},{"value":"9783031062490","type":"electronic"}],"license":[{"start":{"date-parts":[[2022,1,1]],"date-time":"2022-01-01T00:00:00Z","timestamp":1640995200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,5,20]],"date-time":"2022-05-20T00:00:00Z","timestamp":1653004800000},"content-version":"vor","delay-in-days":139,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2022]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Collaborative robotic needle insertions have the potential to improve placement accuracy and safety, e.g., during epidural anesthesia. Epidural anesthesia provides effective regional pain management but can lead to serious complications, such as nerve injury or cerebrospinal fluid leakage. Robotic assistance might prevent inadvertent puncture by providing haptic feedback to the physician. Haptic feedback can be realized on the basis of force measurements at the needle. However, contact should be avoided for delicate structures. We propose a proximity-based method to provide feedback prior to contact. We measure the distance to boundary layers, visualize the proximity for the operator and further feedback it as a haptic resistance. We compare our approach to haptic feedback based on needle forces and visual feedback without haptics. Participants are asked to realize needle insertions with each of the three feedback modes. We use phantoms that mimic the structures punctured during epidural anesthesia. We show that visual feedback improves needle placement, but only proximity-based haptic feedback reduces accidental puncture. The puncture rate is 62% for force-based haptic feedback, 60% for visual feedback and 6% for proximity-based haptic feedback. Final needle placement inside the epidural space is achieved in 38%, 70% and 96% for force-based haptic, visual and proximity-based haptic feedback, respectively. Our results suggest that proximity-based haptic feedback could improve needle placement safety in the context of epidural anesthesia.<\/jats:p>","DOI":"10.1007\/978-3-031-06249-0_34","type":"book-chapter","created":{"date-parts":[[2022,5,19]],"date-time":"2022-05-19T16:05:38Z","timestamp":1652976338000},"page":"301-309","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Proximity-Based Haptic Feedback for Collaborative Robotic Needle Insertion"],"prefix":"10.1007","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0262-2519","authenticated-orcid":false,"given":"Robin","family":"Mieling","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7254-7214","authenticated-orcid":false,"given":"Carolin","family":"Stapper","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stefan","family":"Gerlach","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maximilian","family":"Neidhardt","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sarah","family":"Latus","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Martin","family":"Gromniak","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Philipp","family":"Breitfeld","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alexander","family":"Schlaefer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,5,20]]},"reference":[{"key":"34_CR1","doi-asserted-by":"publisher","unstructured":"Kang, X.H., et al.: Major complications of epidural anesthesia: a prospective study of 5083 cases at a single hospital. Acta Anaesthesiol. Scand. 58(7), 858\u2013866 (2014). https:\/\/doi.org\/10.1111\/aas.12360. https:\/\/onlinelibrary.wiley.com\/doi\/full\/10.1111\/aas.12360","DOI":"10.1111\/aas.12360"},{"key":"34_CR2","doi-asserted-by":"publisher","unstructured":"Bezov, D., Lipton, R.B., Ashina, S.: Post-dural puncture headache: Part I diagnosis, epidemiology, etiology, and pathophysiology. Headache J. Head Face Pain 50(7), 1144\u20131152 (2010). https:\/\/doi.org\/10.1111\/j.1526-4610.2010.01699.x. https:\/\/headachejournal.onlinelibrary.wiley.com\/doi\/full\/10.1111\/j.1526-4610.2010.01699.x","DOI":"10.1111\/j.1526-4610.2010.01699.x"},{"key":"34_CR3","doi-asserted-by":"publisher","unstructured":"Webb, C.A.J., et al.: Unintentional dural puncture with a tuohy needle increases risk of chronic headache. Anesth. Analg. 115(1), 15\u201325 (2012). https:\/\/doi.org\/10.1213\/ANE.0b013e3182501c06. https:\/\/journals.lww.com\/anesthesia-analgesia\/Fulltext\/2012\/07000\/Unintentional_Dural_Puncture_with_a_Tuohy_Needle.22.aspx","DOI":"10.1213\/ANE.0b013e3182501c06"},{"key":"34_CR4","doi-asserted-by":"publisher","unstructured":"Manchikanti, L., Atluri, S.: Chapter 152 - lumbar epidural nerve block. In: Waldman, S.D., Bloch, J.I. (eds.) Pain Management, pp. 1281\u20131293. W.B. Saunders, Philadelphia (2007). https:\/\/doi.org\/10.1016\/B978-0-7216-0334-6.50156-4. https:\/\/www.sciencedirect.com\/science\/article\/pii\/B9780721603346501564","DOI":"10.1016\/B978-0-7216-0334-6.50156-4"},{"issue":"10","key":"34_CR5","doi-asserted-by":"publisher","first-page":"677","DOI":"10.4103\/0019-5049.167483","volume":"59","author":"T Dhansura","year":"2015","unstructured":"Dhansura, T., Shaikh, T., Maadoo, M., Chittalwala, F.: Identification of the epidural space-loss of resistance to saline: an inexpensive modification. Indian J. Anaesth. 59(10), 677\u2013679 (2015). https:\/\/doi.org\/10.4103\/0019-5049.167483","journal-title":"Indian J. Anaesth."},{"key":"34_CR6","doi-asserted-by":"publisher","first-page":"8899628","DOI":"10.1155\/2020\/8899628","volume":"2020","author":"J Yang","year":"2020","unstructured":"Yang, J., et al.: The development of a novel device based on loss of guidewire resistance to identify epidural space in a porcine model. J. Healthc. Eng. 2020, 8899628 (2020). https:\/\/doi.org\/10.1155\/2020\/8899628","journal-title":"J. Healthc. Eng."},{"key":"34_CR7","doi-asserted-by":"publisher","first-page":"94","DOI":"10.1109\/TMRB.2022.3146440","volume":"4","author":"M Neidhardt","year":"2022","unstructured":"Neidhardt, M., et al.: Robotic tissue sampling for safe post-mortem biopsy in infectious corpses. IEEE Trans. Med. Robot. Bionics 4, 94\u2013105 (2022)","journal-title":"IEEE Trans. Med. Robot. Bionics"},{"issue":"2","key":"34_CR8","doi-asserted-by":"publisher","first-page":"379","DOI":"10.1109\/TBME.2012.2227316","volume":"60","author":"D de Lorenzo","year":"2013","unstructured":"de Lorenzo, D., Koseki, Y., de Momi, E., Chinzei, K., Okamura, A.M.: Coaxial needle insertion assistant with enhanced force feedback. IEEE Trans. Biomed. Eng. 60(2), 379\u2013389 (2013). https:\/\/doi.org\/10.1109\/TBME.2012.2227316","journal-title":"IEEE Trans. Biomed. Eng."},{"issue":"10","key":"34_CR9","doi-asserted-by":"publisher","first-page":"1707","DOI":"10.1109\/TBME.2004.831542","volume":"51","author":"AM Okamura","year":"2004","unstructured":"Okamura, A.M., Simone, C., O\u2019Leary, M.D.: Force modeling for needle insertion into soft tissue. IEEE Trans. Bio-med. Eng. 51(10), 1707\u20131716 (2004). https:\/\/doi.org\/10.1109\/TBME.2004.831542","journal-title":"IEEE Trans. Bio-med. Eng."},{"key":"34_CR10","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2021.3063069","author":"S Latus","year":"2021","unstructured":"Latus, S., et al.: Rupture detection during needle insertion using complex OCT data and CNNS. IEEE Trans. Biomed. Eng. (2021). https:\/\/doi.org\/10.1109\/TBME.2021.3063069","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"34_CR11","doi-asserted-by":"publisher","unstructured":"Antonello, R., Oboe, R.: Force controller tuning for a master-slave system with proximity based haptic feedback. In: IECON 2014\u201340th Annual Conference of the IEEE Industrial Electronics Society, pp. 2774\u20132779 (2014). https:\/\/doi.org\/10.1109\/IECON.2014.7048900","DOI":"10.1109\/IECON.2014.7048900"},{"key":"34_CR12","doi-asserted-by":"publisher","unstructured":"Dagnino, G., Liu, J., Abdelaziz, M.E.M.K., Chi, W., Riga, C., Yang, G.Z.: Haptic feedback and dynamic active constraints for robot-assisted endovascular catheterization. In: 2018 IEEE\/RSJ International Conference on Intelligent Robots and Systems (IROS), pp. 1770\u20131775 (2018). https:\/\/doi.org\/10.1109\/IROS.2018.8593628","DOI":"10.1109\/IROS.2018.8593628"}],"container-title":["Lecture Notes in Computer Science","Haptics: Science, Technology, Applications"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-031-06249-0_34","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,3,12]],"date-time":"2024-03-12T11:25:06Z","timestamp":1710242706000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/978-3-031-06249-0_34"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022]]},"ISBN":["9783031062483","9783031062490"],"references-count":12,"URL":"https:\/\/doi.org\/10.1007\/978-3-031-06249-0_34","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"value":"0302-9743","type":"print"},{"value":"1611-3349","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022]]},"assertion":[{"value":"20 May 2022","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}},{"value":"EuroHaptics","order":1,"name":"conference_acronym","label":"Conference Acronym","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"International Conference on Human Haptic Sensing and Touch Enabled Computer Applications","order":2,"name":"conference_name","label":"Conference Name","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Hamburg","order":3,"name":"conference_city","label":"Conference City","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Germany","order":4,"name":"conference_country","label":"Conference Country","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2022","order":5,"name":"conference_year","label":"Conference Year","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"22 May 2022","order":7,"name":"conference_start_date","label":"Conference Start Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"25 May 2022","order":8,"name":"conference_end_date","label":"Conference End Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"13","order":9,"name":"conference_number","label":"Conference Number","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"eurohaptics2022","order":10,"name":"conference_id","label":"Conference ID","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"http:\/\/www.eurohaptics2022.org","order":11,"name":"conference_url","label":"Conference URL","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Single-blind","order":1,"name":"type","label":"Type","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"OCS","order":2,"name":"conference_management_system","label":"Conference Management System","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"129","order":3,"name":"number_of_submissions_sent_for_review","label":"Number of Submissions Sent for Review","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"36","order":4,"name":"number_of_full_papers_accepted","label":"Number of Full Papers Accepted","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"0","order":5,"name":"number_of_short_papers_accepted","label":"Number of Short Papers Accepted","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"28% - The value is computed by the equation \"Number of Full Papers Accepted \/ Number of Submissions Sent for Review * 100\" and then rounded to a whole number.","order":6,"name":"acceptance_rate_of_full_papers","label":"Acceptance Rate of Full Papers","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"2.1","order":7,"name":"average_number_of_reviews_per_paper","label":"Average Number of Reviews per Paper","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"1.8","order":8,"name":"average_number_of_papers_per_reviewer","label":"Average Number of Papers per Reviewer","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"Yes","order":9,"name":"external_reviewers_involved","label":"External Reviewers Involved","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}}]}}