{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T00:55:32Z","timestamp":1781571332830,"version":"3.54.5"},"publisher-location":"Cham","reference-count":10,"publisher":"Springer International Publishing","isbn-type":[{"value":"9783031063879","type":"print"},{"value":"9783031063886","type":"electronic"}],"license":[{"start":{"date-parts":[[2022,1,1]],"date-time":"2022-01-01T00:00:00Z","timestamp":1640995200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2022,1,1]],"date-time":"2022-01-01T00:00:00Z","timestamp":1640995200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2022]]},"DOI":"10.1007\/978-3-031-06388-6_2","type":"book-chapter","created":{"date-parts":[[2022,6,15]],"date-time":"2022-06-15T19:05:23Z","timestamp":1655319923000},"page":"10-17","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Resistive-Force Presentation Device Using Magneto-Rheological Fluid for\u00a0Wrist-Joint Stiffness Control"],"prefix":"10.1007","author":[{"given":"Taiki","family":"Funabiki","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoichi","family":"Yamazaki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masataka","family":"Imura","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,6,16]]},"reference":[{"key":"2_CR1","unstructured":"LORD TECHNICAL DATA. http:\/\/www.lord.com"},{"key":"2_CR2","unstructured":"SensAble Technologies. http:\/\/www.sensable.com\/"},{"issue":"3","key":"2_CR3","first-page":"91","volume":"27","author":"T Fujita","year":"2003","unstructured":"Fujita, T., Shimada, K.: Characteristics and applications of magnetorheological fluids. J. Magn. Soc. Jpn. 27(3), 91\u2013100 (2003)","journal-title":"J. Magn. Soc. Jpn."},{"issue":"2","key":"2_CR4","doi-asserted-by":"publisher","first-page":"849","DOI":"10.1109\/LRA.2017.2655109","volume":"2","author":"S Hauser","year":"2017","unstructured":"Hauser, S., Robertson, M., Ijspeert, A., Paik, J.: JammJoint:: a variable stiffness device based on granular jamming for wearable joint support. IEEE Robot. Autom. Lett. 2(2), 849\u2013855 (2017)","journal-title":"IEEE Robot. Autom. Lett."},{"key":"2_CR5","doi-asserted-by":"crossref","unstructured":"Hoppe, M., et al.: VRHapticDrones: providing haptics in virtual reality through quadcopters. In: Proceedings of the 17th International Conference on Mobile and Ubiquitous Multimedia, pp. 7\u201318 (2018)","DOI":"10.1145\/3282894.3282898"},{"key":"2_CR6","doi-asserted-by":"crossref","unstructured":"Mitsuda, T., Kuge, S., Wakabayashi, M., Kawamura, S.: Haptic displays implemented by controllable passive elements. In: Proceedings 2002 IEEE International Conference on Robotics and Automation. vol. 4, pp. 4223\u20134228 (2002)","DOI":"10.1109\/ROBOT.2002.1014417"},{"issue":"4","key":"2_CR7","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1142\/S0219843616500171","volume":"13","author":"T Nishida","year":"2016","unstructured":"Nishida, T., Okatani, Y., Tadakuma, K.: Development of universal robot gripper using MR$$\\alpha $$ fluid. Int. J. Human. Robot. 13(4), 1\u201312 (2016)","journal-title":"Int. J. Human. Robot."},{"key":"2_CR8","doi-asserted-by":"crossref","unstructured":"Sato, M.: SPIDAR and virtual reality. In: Proceedings of the 5th Biannual World Automation Congress, vol. 13, pp. 17\u201323. TSI Press, Albuquerque (2002)","DOI":"10.1109\/WAC.2002.1049515"},{"key":"2_CR9","doi-asserted-by":"crossref","unstructured":"Taniguchi, Y., Tsumugiwa, T., Yokogawa, R.: Development of force haptic device equipped with 3-DOF parallel mechanism. Trans. Jpn. Soc. Mech. Eng. C 78(793), 3228\u20133238 (2012)","DOI":"10.1299\/kikaic.78.3228"},{"key":"2_CR10","doi-asserted-by":"crossref","unstructured":"Yano, H., Yoshie, M., Iwata, H.: Development of a non-grounded haptic interface using the gyro effect. In: Proceedings of 11th Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems, pp. 32\u201339 (2003)","DOI":"10.1109\/HAPTIC.2003.1191223"}],"container-title":["Communications in Computer and Information Science","HCI International 2022 Posters"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-031-06388-6_2","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T00:34:39Z","timestamp":1781570079000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/978-3-031-06388-6_2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022]]},"ISBN":["9783031063879","9783031063886"],"references-count":10,"URL":"https:\/\/doi.org\/10.1007\/978-3-031-06388-6_2","relation":{},"ISSN":["1865-0929","1865-0937"],"issn-type":[{"value":"1865-0929","type":"print"},{"value":"1865-0937","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022]]},"assertion":[{"value":"16 June 2022","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}},{"value":"HCII","order":1,"name":"conference_acronym","label":"Conference Acronym","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"International Conference on Human-Computer Interaction","order":2,"name":"conference_name","label":"Conference Name","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2022","order":5,"name":"conference_year","label":"Conference Year","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"26 June 2022","order":7,"name":"conference_start_date","label":"Conference Start Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"1 July 2022","order":8,"name":"conference_end_date","label":"Conference End Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"24","order":9,"name":"conference_number","label":"Conference Number","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"hcii2022","order":10,"name":"conference_id","label":"Conference ID","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"https:\/\/2022.hci.international\/index.html","order":11,"name":"conference_url","label":"Conference URL","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"This content has been made available to all.","name":"free","label":"Free to read"}]}}