{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,3,26]],"date-time":"2025-03-26T14:24:46Z","timestamp":1742999086456,"version":"3.40.3"},"publisher-location":"Cham","reference-count":20,"publisher":"Springer International Publishing","isbn-type":[{"type":"print","value":"9783031088377"},{"type":"electronic","value":"9783031088384"}],"license":[{"start":{"date-parts":[[2022,1,1]],"date-time":"2022-01-01T00:00:00Z","timestamp":1640995200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2022,1,1]],"date-time":"2022-01-01T00:00:00Z","timestamp":1640995200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2022]]},"DOI":"10.1007\/978-3-031-08838-4_14","type":"book-chapter","created":{"date-parts":[[2022,7,28]],"date-time":"2022-07-28T12:56:27Z","timestamp":1659012987000},"page":"189-204","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Heart Rate Estimation Using the\u00a0EVM Method, the\u00a0FFT and\u00a0MUSIC Algorithms Under Different Conditions"],"prefix":"10.1007","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4870-0914","authenticated-orcid":false,"given":"Manola","family":"Ricciuti","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8798-4588","authenticated-orcid":false,"given":"Linda","family":"Senigagliesi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6852-8483","authenticated-orcid":false,"given":"Ennio","family":"Gambi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,7,29]]},"reference":[{"key":"14_CR1","doi-asserted-by":"publisher","first-page":"65:1","DOI":"10.1145\/2185520.2185561","volume":"31","author":"H-Y Wu","year":"2012","unstructured":"Wu, H.-Y., Rubinstein, M., Shih, E., Guttag, J., Durand, F., Freeman, W.: Eulerian video magnification for revealing subtle changes in the world. ACM Trans. Graph. 31, 65:1-65:8 (2012)","journal-title":"ACM Trans. Graph."},{"doi-asserted-by":"crossref","unstructured":"Fletcher, R.R., Chamberlain, D., Paggi, N., Deng, X.: Implementation of smart phone video plethysmography and dependence on lighting parameters. In: 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), pp. 3747\u20133750 (2015)","key":"14_CR2","DOI":"10.1109\/EMBC.2015.7319208"},{"issue":"2","key":"14_CR3","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1023\/B:VISI.0000013087.49260.fb","volume":"57","author":"P Viola","year":"2004","unstructured":"Viola, P., Jones, M.J.: Robust real-time face detection. Int. J. Comput. Vision 57(2), 137\u2013154 (2004)","journal-title":"Int. J. Comput. Vision"},{"issue":"8","key":"14_CR4","doi-asserted-by":"publisher","first-page":"1776","DOI":"10.3390\/s17081776","volume":"17","author":"E Gambi","year":"2017","unstructured":"Gambi, E., et al.: Heart rate detection using microsoft kinect: validation and comparison to wearable devices. Sensors 17(8), 1776 (2017)","journal-title":"Sensors"},{"doi-asserted-by":"crossref","unstructured":"Secerbegovic, A., Bergsland, J., Halvorsen, P.S., Suljanovic, N., Mujcic, A., Balasingham, I.: Blood pressure estimation using video plethysmography. In: 2016 IEEE 13th International Symposium on Biomedical Imaging (ISBI), pp. 461\u2013464, April 2016","key":"14_CR5","DOI":"10.1109\/ISBI.2016.7493307"},{"key":"14_CR6","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1109\/TBME.2010.2086456","volume":"58","author":"MZ Poh","year":"2011","unstructured":"Poh, M.Z., McDuff, D.J., Picard, R.W.: Advancements in noncontact, multiparameter physiological measurements using a webcam. IEEE Trans. Biomed. Eng. 58, 7\u201311 (2011)","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"14_CR7","doi-asserted-by":"publisher","first-page":"4711","DOI":"10.1109\/ACCESS.2017.2678521","volume":"5","author":"K Alghoul","year":"2017","unstructured":"Alghoul, K., Alharthi, S., Osman, H.A., Saddik, A.E.: Heart rate variability extraction from videos signals: ICA vs. EVM comparison. IEEE Access 5, 4711\u20134719 (2017)","journal-title":"IEEE Access"},{"doi-asserted-by":"crossref","unstructured":"Bennett, S.L., Goubran, R., Knoefel, F.: Adaptive eulerian video magnification methods to extract heart rate from thermal video. In: 2016 IEEE International Symposium on Medical Measurements and Applications (MeMeA), pp. 1\u20135. IEEE (2016)","key":"14_CR8","DOI":"10.1109\/MeMeA.2016.7533818"},{"doi-asserted-by":"crossref","unstructured":"Miljkovi\u0107, N., Trifunovi\u0107, D.: Pulse rate assessment: eulerian video magnification vs. electrocardiography recordings. In: 12th Symposium on Neural Network Applications in Electrical Engineering (NEUREL), pp. 17\u201320. IEEE (2014)","key":"14_CR9","DOI":"10.1109\/NEUREL.2014.7011447"},{"doi-asserted-by":"crossref","unstructured":"Shahadi, H.I., Al-allaq, Z.J., Albattat, H.J.: Efficient denoising approach based eulerian video magnification for colour and motion variations. Int. J. Electr. Comput. Eng. (2088\u20138708) 10 (2020)","key":"14_CR10","DOI":"10.11591\/ijece.v10i5.pp4701-4711"},{"issue":"7","key":"14_CR11","doi-asserted-by":"publisher","first-page":"1293","DOI":"10.1007\/s11760-018-1282-0","volume":"12","author":"X Wu","year":"2018","unstructured":"Wu, X., Yang, X., Jin, J., Yang, Z.: PCA-based magnification method for revealing small signals in video. SIViP 12(7), 1293\u20131299 (2018)","journal-title":"SIViP"},{"doi-asserted-by":"crossref","unstructured":"Madhav, K.V., Ram, M.R., Krishna, E.H., Reddy, K.N., Reddy, K.A.: Estimation of respiratory rate from principal components of photoplethysmographic signals. In: 2010 IEEE EMBS Conference on Biomedical Engineering and Sciences (IECBES), pp. 311\u2013314 (2010)","key":"14_CR12","DOI":"10.1109\/IECBES.2010.5742251"},{"doi-asserted-by":"crossref","unstructured":"Ciattaglia, G., Senigagliesi, L., De Santis, A., Ricciuti, M.: Contactless measurement of physiological parameters. In: 2019 IEEE 9th International Conference on Consumer Electronics (ICCE-Berlin), pp. 22\u201326 (2019)","key":"14_CR13","DOI":"10.1109\/ICCE-Berlin47944.2019.8966140"},{"doi-asserted-by":"crossref","unstructured":"Ricciuti, M., Ciattaglia, G., De Santis, A., Gambi, E., Senigagliesi, L.: Contactless heart rate measurements using RGB-camera and radar. In: ICT4AWE, pp. 121\u2013129 (2020)","key":"14_CR14","DOI":"10.5220\/0009793201210129"},{"doi-asserted-by":"crossref","unstructured":"Chen, Q., Jiang, X., Liu, X., Lu, C., Wang, L., Chen, W.: Non-contact heart rate monitoring in neonatal intensive care unit using RGB camera. In: 2020 42nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), pp. 5822\u20135825. IEEE (2020)","key":"14_CR15","DOI":"10.1109\/EMBC44109.2020.9175651"},{"doi-asserted-by":"crossref","unstructured":"Hui, M.L., Nisar, H., Ho, Y.K., Chiong, T.P.: A video based heart rate monitoring system for drivers using photoplethysmography signal. In: 2018 IEEE Region 10 Humanitarian Technology Conference (R10-HTC), pp. 1\u20136. IEEE (2018)","key":"14_CR16","DOI":"10.1109\/R10-HTC.2018.8629825"},{"doi-asserted-by":"crossref","unstructured":"Dosso, Y.S., Bekele, A., Green, J.R.: Eulerian magnification of multi-modal RGB-D video for heart rate estimation. In: 2018 IEEE International Symposium on Medical Measurements and Applications (MeMeA), pp. 1\u20136. IEEE (2018)","key":"14_CR17","DOI":"10.1109\/MeMeA.2018.8438741"},{"doi-asserted-by":"crossref","unstructured":"Aubakir, B., Nurimbetov, B., Tursynbek, I., Varol, H.A.: Vital sign monitoring utilizing eulerian video magnification and thermography. In: 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), pp. 3527\u20133530. IEEE (2016)","key":"14_CR18","DOI":"10.1109\/EMBC.2016.7591489"},{"doi-asserted-by":"crossref","unstructured":"Li, T., Tang, Y.: Frequency estimation based on modulation FFT and music algorithm. In: 2010 First International Conference on Pervasive Computing, Signal Processing and Applications, pp. 525\u2013528. IEEE (2010)","key":"14_CR19","DOI":"10.1109\/PCSPA.2010.132"},{"key":"14_CR20","doi-asserted-by":"publisher","first-page":"287","DOI":"10.1016\/j.bspc.2018.01.024","volume":"42","author":"Z Wei","year":"2018","unstructured":"Wei, Z., Xiaolong, L., Jin, Z., Xueyun, W., Hongxing, L.: Foetal heart rate estimation by empirical mode decomposition and music spectrum. Biomed. Signal Process. Control 42, 287\u2013296 (2018)","journal-title":"Biomed. Signal Process. Control"}],"container-title":["Lecture Notes in Electrical Engineering","Ambient Assisted Living"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-031-08838-4_14","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,2,12]],"date-time":"2023-02-12T21:44:58Z","timestamp":1676238298000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/978-3-031-08838-4_14"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022]]},"ISBN":["9783031088377","9783031088384"],"references-count":20,"URL":"https:\/\/doi.org\/10.1007\/978-3-031-08838-4_14","relation":{},"ISSN":["1876-1100","1876-1119"],"issn-type":[{"type":"print","value":"1876-1100"},{"type":"electronic","value":"1876-1119"}],"subject":[],"published":{"date-parts":[[2022]]},"assertion":[{"value":"29 July 2022","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}},{"value":"ForItAAL","order":1,"name":"conference_acronym","label":"Conference Acronym","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Italian Forum of Ambient Assisted Living","order":2,"name":"conference_name","label":"Conference Name","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2020","order":5,"name":"conference_year","label":"Conference Year","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"1 December 2020","order":7,"name":"conference_start_date","label":"Conference Start Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"1 December 2020","order":8,"name":"conference_end_date","label":"Conference End Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"11","order":9,"name":"conference_number","label":"Conference Number","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"foritaal2020","order":10,"name":"conference_id","label":"Conference ID","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"http:\/\/www.foritaal2020.it\/","order":11,"name":"conference_url","label":"Conference URL","group":{"name":"ConferenceInfo","label":"Conference Information"}}]}}