{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,3,26]],"date-time":"2025-03-26T18:57:45Z","timestamp":1743015465670,"version":"3.40.3"},"publisher-location":"Cham","reference-count":16,"publisher":"Springer International Publishing","isbn-type":[{"type":"print","value":"9783031120527"},{"type":"electronic","value":"9783031120534"}],"license":[{"start":{"date-parts":[[2022,1,1]],"date-time":"2022-01-01T00:00:00Z","timestamp":1640995200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2022,1,1]],"date-time":"2022-01-01T00:00:00Z","timestamp":1640995200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2022]]},"DOI":"10.1007\/978-3-031-12053-4_51","type":"book-chapter","created":{"date-parts":[[2022,7,25]],"date-time":"2022-07-25T09:15:50Z","timestamp":1658740550000},"page":"692-702","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["High-Quality 4D-CBCT Imaging from Single Routine Scan"],"prefix":"10.1007","author":[{"given":"Huihui","family":"Li","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pengfei","family":"Yang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xin","family":"Ge","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tianye","family":"Niu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,7,25]]},"reference":[{"key":"51_CR1","doi-asserted-by":"crossref","unstructured":"Goyal, S., Kataria, T.: Image guidance in radiation therapy: techniques and applications. Radiol. Res. Pract., 705604 (2014)","DOI":"10.1155\/2014\/705604"},{"key":"51_CR2","doi-asserted-by":"publisher","first-page":"1720","DOI":"10.1002\/cncr.10856","volume":"95","author":"T Harada","year":"2002","unstructured":"Harada, T., et al.: Real-time tumor-tracking radiation therapy for lung carcinoma by the aid of insertion of a gold marker using bronchofiberscopy. Cancer 95, 1720\u20131727 (2002)","journal-title":"Cancer"},{"issue":"2","key":"51_CR3","doi-asserted-by":"publisher","first-page":"305","DOI":"10.1016\/j.ejmp.2015.10.093","volume":"32","author":"K Harada","year":"2016","unstructured":"Harada, K., et al.: Evaluation of the motion of lung tumors during stereotactic body radiation therapy (SBRT) with four-dimensional computed tomography (4DCT) using real-time tumor-tracking radiotherapy system (RTRT). Physica Med. 32(2), 305\u2013311 (2016)","journal-title":"Physica Med."},{"key":"51_CR4","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1088\/0031-9155\/56\/1\/015","volume":"56","author":"J McClelland","year":"2011","unstructured":"McClelland, J., et al.: Inter-fraction variations in respiratory motion models. Phys. Med. Biol. 56, 251\u2013272 (2011)","journal-title":"Phys. Med. Biol."},{"issue":"8","key":"51_CR5","doi-asserted-by":"publisher","first-page":"3109","DOI":"10.1088\/0031-9155\/61\/8\/3109","volume":"61","author":"M Chao","year":"2016","unstructured":"Chao, M., et al.: Robust breathing signal extraction from cone beam CT projections based on adaptive and global optimization techniques. Phys. Med. Biol. 61(8), 3109\u20133126 (2016)","journal-title":"Phys. Med. Biol."},{"issue":"8","key":"51_CR6","doi-asserted-by":"publisher","first-page":"1365","DOI":"10.1109\/TMI.2012.2231694","volume":"32","author":"M Chen","year":"2013","unstructured":"Chen, M., et al.: Motion-compensated mega-voltage cone beam CT using the deformation derived directly from 2D projection images. IEEE Trans. Med. Imaging 32(8), 1365\u20131375 (2013)","journal-title":"IEEE Trans. Med. Imaging"},{"issue":"9","key":"51_CR7","doi-asserted-by":"publisher","first-page":"5592","DOI":"10.1118\/1.4745559","volume":"39","author":"X Jia","year":"2012","unstructured":"Jia, X., et al.: Four-dimensional cone beam CT reconstruction and enhancement using a temporal nonlocal means method. Med. Phys. 39(9), 5592\u20135602 (2012)","journal-title":"Med. Phys."},{"issue":"2","key":"51_CR8","first-page":"177","volume":"21","author":"K Choi","year":"2013","unstructured":"Choi, K., et al.: Enhancement of four-dimensional cone-beam computed tomography by compressed sensing with Bregman iteration. J. Xray Sci. Technol. 21(2), 177\u2013192 (2013)","journal-title":"J. Xray Sci. Technol."},{"issue":"11","key":"51_CR9","doi-asserted-by":"publisher","first-page":"6943","DOI":"10.1118\/1.4762288","volume":"39","author":"H Gao","year":"2012","unstructured":"Gao, H., et al.: 4D cone beam CT via spatiotemporal tensor framelet. Med. Phys. 39(11), 6943\u20136946 (2012)","journal-title":"Med. Phys."},{"issue":"10","key":"51_CR10","doi-asserted-by":"publisher","first-page":"5530","DOI":"10.1118\/1.3637501","volume":"38","author":"Z Qi","year":"2011","unstructured":"Qi, Z., Chen, G.H.: Extraction of tumor motion trajectories using PICCS-4DCBCT: a validation study. Med. Phys. 38(10), 5530\u20135538 (2011)","journal-title":"Med. Phys."},{"issue":"9","key":"51_CR11","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ab07d6","volume":"64","author":"G Chee","year":"2019","unstructured":"Chee, G., et al.: McSART: an iterative model-based, motion-compensated SART algorithm for CBCT reconstruction. Phys. Med. Biol. 64(9), 095013 (2019)","journal-title":"Phys. Med. Biol."},{"issue":"12","key":"51_CR12","doi-asserted-by":"publisher","first-page":"7603","DOI":"10.1118\/1.4766435","volume":"39","author":"M Brehm","year":"2012","unstructured":"Brehm, M., et al.: Self-adapting cyclic registration for motion-compensated cone-beam CT in image-guided radiation therapy. Med. Phys. 39(12), 7603\u20137618 (2012)","journal-title":"Med. Phys."},{"issue":"3","key":"51_CR13","doi-asserted-by":"publisher","first-page":"355","DOI":"10.1016\/j.radonc.2017.04.022","volume":"123","author":"C Hazelaar","year":"2017","unstructured":"Hazelaar, C., et al.: Verifying tumor position during stereotactic body radiation therapy delivery using (limited-arc) cone beam computed tomography imaging. Radiother. Oncol. 123(3), 355\u2013362 (2017)","journal-title":"Radiother. Oncol."},{"issue":"3","key":"51_CR14","doi-asserted-by":"publisher","first-page":"1442","DOI":"10.1118\/1.3685443","volume":"39","author":"I Vergalasova","year":"2012","unstructured":"Vergalasova, I., Cai, J., Yin, F.F.: A novel technique for markerless, self-sorted 4D-CBCT: feasibility study. Med. Phys. 39(3), 1442\u20131451 (2012)","journal-title":"Med. Phys."},{"issue":"3","key":"51_CR15","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1016\/j.cmpb.2012.09.006","volume":"109","author":"W Qiu","year":"2013","unstructured":"Qiu, W., et al.: Evaluating iterative algebraic algorithms in terms of convergence and image quality for cone beam CT. Comput. Methods Programs Biomed. 109(3), 313\u2013322 (2013)","journal-title":"Comput. Methods Programs Biomed."},{"issue":"1","key":"51_CR16","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1118\/1.1455742","volume":"29","author":"AC Kak","year":"2002","unstructured":"Kak, A.C., Slaney, M., Wang, G.: Principles of computerized tomographic imaging. Med. Phys. 29(1), 107 (2002)","journal-title":"Med. Phys."}],"container-title":["Lecture Notes in Computer Science","Medical Image Understanding and Analysis"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-031-12053-4_51","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,8]],"date-time":"2024-02-08T08:10:55Z","timestamp":1707379855000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/978-3-031-12053-4_51"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022]]},"ISBN":["9783031120527","9783031120534"],"references-count":16,"URL":"https:\/\/doi.org\/10.1007\/978-3-031-12053-4_51","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"type":"print","value":"0302-9743"},{"type":"electronic","value":"1611-3349"}],"subject":[],"published":{"date-parts":[[2022]]},"assertion":[{"value":"25 July 2022","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}},{"value":"MIUA","order":1,"name":"conference_acronym","label":"Conference Acronym","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Annual Conference on Medical Image Understanding and Analysis","order":2,"name":"conference_name","label":"Conference Name","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Cambridge","order":3,"name":"conference_city","label":"Conference City","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"United Kingdom","order":4,"name":"conference_country","label":"Conference Country","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2022","order":5,"name":"conference_year","label":"Conference Year","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"27 July 2022","order":7,"name":"conference_start_date","label":"Conference Start Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"29 July 2022","order":8,"name":"conference_end_date","label":"Conference End Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"26","order":9,"name":"conference_number","label":"Conference Number","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"miua2022","order":10,"name":"conference_id","label":"Conference ID","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"https:\/\/www.miua2022.com\/home","order":11,"name":"conference_url","label":"Conference URL","group":{"name":"ConferenceInfo","label":"Conference Information"}}]}}