{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,3,26]],"date-time":"2025-03-26T20:23:07Z","timestamp":1743020587451,"version":"3.40.3"},"publisher-location":"Cham","reference-count":25,"publisher":"Springer International Publishing","isbn-type":[{"type":"print","value":"9783031213328"},{"type":"electronic","value":"9783031213335"}],"license":[{"start":{"date-parts":[[2022,11,21]],"date-time":"2022-11-21T00:00:00Z","timestamp":1668988800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2022,11,21]],"date-time":"2022-11-21T00:00:00Z","timestamp":1668988800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2023]]},"DOI":"10.1007\/978-3-031-21333-5_1","type":"book-chapter","created":{"date-parts":[[2022,11,20]],"date-time":"2022-11-20T19:02:43Z","timestamp":1668970963000},"page":"3-14","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["MoveLeg: An Assistive Device for\u00a0the\u00a0Motor Tele-Rehabilitation of\u00a0the\u00a0Lower Limbs"],"prefix":"10.1007","author":[{"given":"Gustavo","family":"Castill\u00f3n-Ram\u00edrez","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cristina","family":"Ram\u00edrez-Fern\u00e1ndez","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alberto L.","family":"Mor\u00e1n","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ismael","family":"Hern\u00e1ndez-Capuchin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Victoria","family":"Meza-Kubo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Karina","family":"Reyes-Lio","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eddie","family":"Clemente","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,11,21]]},"reference":[{"key":"1_CR1","unstructured":"WHO, UNICEF Global report on assistive technology (2022)"},{"issue":"1","key":"1_CR2","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/1472-6963-13-334","volume":"13","author":"S Demain","year":"2013","unstructured":"Demain, S., Burridge, J., Ellis-Hill, C., et al.: Assistive technologies after stroke: self-management or fending for yourself? A focus group study. BMC Health Serv. Res. 13(1), 1\u201312 (2013)","journal-title":"BMC Health Serv. Res."},{"key":"1_CR3","doi-asserted-by":"publisher","first-page":"517","DOI":"10.1161\/STR.0b013e3181fcb238","volume":"42","author":"LB Goldstein","year":"2011","unstructured":"Goldstein, L.B., Bushnell, C.D., Adams, R.J., et al.: guidelines for the primary prevention of stroke: a guideline for healthcare professionals from the American heart association\/American stroke association. Stroke 42, 517\u2013584 (2011)","journal-title":"Stroke"},{"key":"1_CR4","doi-asserted-by":"publisher","first-page":"817","DOI":"10.1007\/s00415-011-6247-y","volume":"259","author":"SJ Albert","year":"2012","unstructured":"Albert, S.J., Kesselring, J.: Neurorehabilitation of stroke. J. Neurol. 259, 817\u2013832 (2012). https:\/\/doi.org\/10.1007\/s00415-011-6247-y","journal-title":"J. Neurol."},{"key":"1_CR5","doi-asserted-by":"publisher","first-page":"75","DOI":"10.2147\/TCRM.S206883","volume":"16","author":"D Gandhi","year":"2020","unstructured":"Gandhi, D., Sterba, A., Khatter, H., Pandian, J.D.: Mirror therapy in stroke rehabilitation: current perspectives. Ther. Clin. Risk Manag. 16, 75\u201385 (2020)","journal-title":"Ther. Clin. Risk Manag."},{"key":"1_CR6","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1016\/j.mechatronics.2015.04.005","volume":"31","author":"W Meng","year":"2015","unstructured":"Meng, W., Liu, Q., Zhou, Z., et al.: Recent development of mechanisms and control strategies for robot-assisted lower limb rehabilitation. Mechatronics 31, 132\u2013145 (2015)","journal-title":"Mechatronics"},{"key":"1_CR7","doi-asserted-by":"publisher","first-page":"492","DOI":"10.1080\/17483107.2018.1472306","volume":"13","author":"M MacLachlan","year":"2018","unstructured":"MacLachlan, M., Scherer, M.: Systems thinking for assistive technology: a commentary on the GREAT summit. Disabil. Rehabil. Assist. Technol. 13, 492\u2013496 (2018)","journal-title":"Disabil. Rehabil. Assist. Technol."},{"key":"1_CR8","unstructured":"WHO.: Rehabilitation in Health Systems (2017)"},{"key":"1_CR9","doi-asserted-by":"crossref","unstructured":"Ruiz-Zafra, \u00c1., Benghazi, K., Noguera, M., Garrido, J.: Zappa: an open mobile platform to build cloud-Based m-health systems. In: Advances in Intelligent Systems and Computing, pp 87\u201394 (2013)","DOI":"10.1007\/978-3-319-00566-9_12"},{"key":"1_CR10","series-title":"Communications in Computer and Information Science","doi-asserted-by":"publisher","first-page":"266","DOI":"10.1007\/978-3-642-45364-9_22","volume-title":"Advances in Service-Oriented and Cloud Computing","author":"A Ruiz-Zafra","year":"2013","unstructured":"Ruiz-Zafra, A., Noguera, M., Benghazi, K., Garrido, J.L., Urbano, G.C., Caracuel, A.: Cloud and web services integration for mHealth telerehabilitation support. In: Canal, C., Villari, M. (eds.) ESOCC 2013. CCIS, vol. 393, pp. 266\u2013276. Springer, Heidelberg (2013). https:\/\/doi.org\/10.1007\/978-3-642-45364-9_22"},{"key":"1_CR11","doi-asserted-by":"publisher","first-page":"597","DOI":"10.1163\/156855301742030","volume":"14","author":"S Okada","year":"2000","unstructured":"Okada, S., Sakaki, T., Hirata, R., et al.: TEM: a therapeutic exercise machine for the lower extremities of spastic patients. Adv. Robot. 14, 597\u2013606 (2000)","journal-title":"Adv. Robot."},{"key":"1_CR12","unstructured":"Girone, M., Burdea, G., Bouzit, M., et al.: A Stewart Platform-Based System for Ankle Telerehabilitation. In: Proceedings of the ASME, Dynamic Systems and Control Division, pp 203\u2013212 (2001)"},{"key":"1_CR13","doi-asserted-by":"publisher","first-page":"1216","DOI":"10.1177\/0278364909104221","volume":"28","author":"J Saglia","year":"2009","unstructured":"Saglia, J., Tsagarakis, N., Dai, J., Caldwell, D.: A high-performance redundantly actuated parallel mechanism for ankle rehabilitation. Int. J. Rob. Res. 28, 1216\u20131227 (2009)","journal-title":"Int. J. Rob. Res."},{"key":"1_CR14","doi-asserted-by":"publisher","first-page":"8128","DOI":"10.1016\/j.eswa.2010.12.154","volume":"38","author":"S Xie","year":"2011","unstructured":"Xie, S., Jamwal, P.: An iterative fuzzy controller for pneumatic muscle driven rehabilitation robot. Expert Syst. Appl. 38, 8128\u20138137 (2011)","journal-title":"Expert Syst. Appl."},{"key":"1_CR15","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1016\/j.mechatronics.2008.07.006","volume":"19","author":"D Bradley","year":"2009","unstructured":"Bradley, D., Acosta-Marquez, C., Hawley, M., et al.: NeXOS-The design, development and evaluation of a rehabilitation system for the lower limbs. Mechatronics 19, 247\u2013257 (2009)","journal-title":"Mechatronics"},{"key":"1_CR16","doi-asserted-by":"publisher","first-page":"509","DOI":"10.1016\/j.mechatronics.2011.01.005","volume":"21","author":"E Akdo\u01e7an","year":"2011","unstructured":"Akdo\u01e7an, E., Adli, M.: The design and control of a therapeutic exercise robot for lower limb rehabilitation: Physiotherabot. Mechatronics 21, 509\u2013522 (2011)","journal-title":"Mechatronics"},{"key":"1_CR17","unstructured":"Kinetec Spectra Knee CPM Machine. https:\/\/www.kinetecusa.com\/kinetec-spectra-with-washable-pads. Accessed 25 June 2021"},{"key":"1_CR18","unstructured":"Kinetec Breva Ankle\/Foot CPM. https:\/\/www.kinetecusa.com\/kinetec-breva. Accessed 31 Oct 2017"},{"key":"1_CR19","unstructured":"CPM 4060. http:\/\/www.innovamedica.com.ec\/productos-carci-biomecanica.html. Accessed 15 Sep 2018"},{"key":"1_CR20","unstructured":"CPMotion. https:\/\/www.btlnet.es\/productos-fisioterapia-cpmotion. Accesed 28 Feb 2016"},{"key":"1_CR21","unstructured":"Knee CPM. https:\/\/medicalpremium.com.mx\/producto\/movilizador-rodilla-renta-terapia\/. Accessed 30 June 2016"},{"key":"1_CR22","unstructured":"Knee CPM. https:\/\/medicalpremium.com.mx\/producto\/movilizador-rodillas\/. Accessed 25 Feb 2017"},{"key":"1_CR23","unstructured":"Avila-Chaurand, R., Prado-Le\u00f3n, L., Gonz\u00e1lez-Mu\u00f1oz, E.: Dimensiones antropom\u00e9tricas de poblaci\u00f3n latinoamericana. Universidad de Guadalajara (2007)"},{"issue":"194","key":"1_CR24","first-page":"4","volume":"189","author":"J Brooke","year":"1996","unstructured":"Brooke, J.: SUS - A quick and dirty usability scale. Usability Eval. Ind. 189(194), 4\u20137 (1996)","journal-title":"Usability Eval. Ind."},{"key":"1_CR25","doi-asserted-by":"publisher","first-page":"319","DOI":"10.2307\/249008","volume":"13","author":"F Davis","year":"1989","unstructured":"Davis, F.: Perceived usefulness, perceived ease of use, and user acceptance of information technology. MIS Q. 13, 319\u2013340 (1989)","journal-title":"MIS Q."}],"container-title":["Lecture Notes in Networks and Systems","Proceedings of the International Conference on Ubiquitous Computing &amp; Ambient Intelligence (UCAmI 2022)"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-031-21333-5_1","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,11,20]],"date-time":"2022-11-20T19:03:14Z","timestamp":1668970994000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/978-3-031-21333-5_1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,11,21]]},"ISBN":["9783031213328","9783031213335"],"references-count":25,"URL":"https:\/\/doi.org\/10.1007\/978-3-031-21333-5_1","relation":{},"ISSN":["2367-3370","2367-3389"],"issn-type":[{"type":"print","value":"2367-3370"},{"type":"electronic","value":"2367-3389"}],"subject":[],"published":{"date-parts":[[2022,11,21]]},"assertion":[{"value":"21 November 2022","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}},{"value":"UCAmI","order":1,"name":"conference_acronym","label":"Conference Acronym","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"International Conference on Ubiquitous Computing and Ambient Intelligence","order":2,"name":"conference_name","label":"Conference Name","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"C\u00f3rdoba","order":3,"name":"conference_city","label":"Conference City","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Spain","order":4,"name":"conference_country","label":"Conference Country","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2022","order":5,"name":"conference_year","label":"Conference Year","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"29 November 2022","order":7,"name":"conference_start_date","label":"Conference Start Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2 December 2022","order":8,"name":"conference_end_date","label":"Conference End Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"ucami2022","order":10,"name":"conference_id","label":"Conference ID","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"https:\/\/mamilab.eu\/ucami2022\/","order":11,"name":"conference_url","label":"Conference URL","group":{"name":"ConferenceInfo","label":"Conference Information"}}]}}