{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,3,26]],"date-time":"2025-03-26T06:36:44Z","timestamp":1742971004301,"version":"3.40.3"},"publisher-location":"Cham","reference-count":19,"publisher":"Springer Nature Switzerland","isbn-type":[{"type":"print","value":"9783031340475"},{"type":"electronic","value":"9783031340482"}],"license":[{"start":{"date-parts":[[2023,1,1]],"date-time":"2023-01-01T00:00:00Z","timestamp":1672531200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2023,1,1]],"date-time":"2023-01-01T00:00:00Z","timestamp":1672531200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2023]]},"DOI":"10.1007\/978-3-031-34048-2_37","type":"book-chapter","created":{"date-parts":[[2023,6,7]],"date-time":"2023-06-07T12:03:35Z","timestamp":1686139415000},"page":"485-496","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Differentiable Gamma Index-Based Loss Functions: Accelerating Monte-Carlo Radiotherapy Dose Simulation"],"prefix":"10.1007","author":[{"given":"Sonia","family":"Martinot","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nikos","family":"Komodakis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maria","family":"Vakalopoulou","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Norbert","family":"Bus","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Charlotte","family":"Robert","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eric","family":"Deutsch","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nikos","family":"Paragios","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2023,6,8]]},"reference":[{"issue":"4","key":"37_CR1","doi-asserted-by":"publisher","first-page":"577","DOI":"10.1118\/1.596360","volume":"16","author":"A Ahnesj\u00f6","year":"1989","unstructured":"Ahnesj\u00f6, A.: Collapsed cone convolution of radiant energy for photon dose calculation in heterogeneous media. Med. Phys. 16(4), 577\u2013592 (1989)","journal-title":"Med. Phys."},{"issue":"78","key":"37_CR2","doi-asserted-by":"publisher","first-page":"4555","DOI":"10.21105\/joss.04555","volume":"7","author":"S Biggs","year":"2022","unstructured":"Biggs, S., et al.: Pymedphys: a community effort to develop an open, python-based standard library for medical physics applications. J. Open Source Softw. 7(78), 4555 (2022)","journal-title":"J. Open Source Softw."},{"issue":"7","key":"37_CR3","doi-asserted-by":"publisher","first-page":"2037","DOI":"10.1088\/0031-9155\/54\/7\/012","volume":"54","author":"M Chen","year":"2009","unstructured":"Chen, M., Lu, W., Chen, Q., Ruchala, K., Olivera, G.: Efficient gamma index calculation using fast Euclidean distance transform. Phys. Med. Biol. 54(7), 2037 (2009)","journal-title":"Phys. Med. Biol."},{"issue":"3","key":"37_CR4","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1016\/j.radmp.2022.07.002","volume":"3","author":"Y Deng","year":"2022","unstructured":"Deng, Y., et al.: Comparison of pencil beam and Monte Carlo calculations with ion chamber array measurements for patient-specific quality assurance. Radiat. Med. Prot. 3(3), 115\u2013122 (2022)","journal-title":"Radiat. Med. Prot."},{"issue":"5","key":"37_CR5","doi-asserted-by":"publisher","first-page":"1431","DOI":"10.1088\/0031-9155\/56\/5\/014","volume":"56","author":"X Gu","year":"2011","unstructured":"Gu, X., Jia, X., Jiang, S.B.: GPU-based fast gamma index calculation. Phys. Med. Biol. 56(5), 1431 (2011)","journal-title":"Phys. Med. Biol."},{"key":"37_CR6","doi-asserted-by":"crossref","unstructured":"Lee, B.I., Boss, M., LaRue, S.M., Martin, T.W., Leary, D.: Comparative study of the collapsed cone convolution and monte carlo algorithms for radiation therapy planning of canine sinonasal tumors reveals significant dosimetric differences. Veterinary Radiol. Ultrasound Official J. Am. Coll. Veterinary Radiol. Int. Veterinary Radiol. Assoc. 63 (2021)","DOI":"10.1111\/vru.13039"},{"key":"37_CR7","doi-asserted-by":"crossref","unstructured":"Lin, T.Y., Goyal, P., Girshick, R.B., He, K., Doll\u00e1r, P.: Focal loss for dense object detection. In: 2017 IEEE ICCV, pp. 2999\u20133007 (2017)","DOI":"10.1109\/ICCV.2017.324"},{"key":"37_CR8","doi-asserted-by":"crossref","unstructured":"Liu, Z., Mao, H., Wu, C.Y., Feichtenhofer, C., Darrell, T., Xie, S.: A convnet for the 2020s. In: Proceedings of the IEEE\/CVF Conference on Computer Vision and Pattern Recognition, pp. 11976\u201311986 (2022)","DOI":"10.1109\/CVPR52688.2022.01167"},{"key":"37_CR9","unstructured":"Loshchilov, I., Hutter, F.: Decoupled weight decay regularization. arXiv preprint arXiv:1711.05101 (2017)"},{"key":"37_CR10","doi-asserted-by":"crossref","unstructured":"Martinot, S., Bus, N., Vakalopoulou, M., Robert, C., Deutsch, E., Paragios, N.: High-particle simulation of monte-carlo dose distribution with 3D convlstms. In: MICCAI, pp. 499\u2013508 (2021)","DOI":"10.1007\/978-3-030-87202-1_48"},{"issue":"1","key":"37_CR11","doi-asserted-by":"publisher","first-page":"64","DOI":"10.1118\/1.595924","volume":"13","author":"R Mohan","year":"1986","unstructured":"Mohan, R., Chui, C., Lidofsky, L.: Differential pencil beam dose computation model for photons. Med. Phys. 13(1), 64\u201373 (1986)","journal-title":"Med. Phys."},{"issue":"3","key":"37_CR12","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/abca01","volume":"66","author":"R Neph","year":"2021","unstructured":"Neph, R., Lyu, Q., Huang, Y., Yang, Y.M., Sheng, K.: Deepmc: a deep learning method for efficient monte carlo beamlet dose calculation by predictive denoising in magnetic resonance-guided radiotherapy. Phys. Med. Biol. 66(3), 035022 (2021)","journal-title":"Phys. Med. Biol."},{"key":"37_CR13","doi-asserted-by":"publisher","first-page":"1169","DOI":"10.1016\/j.ijrobp.2011.09.015","volume":"83","author":"E Quan","year":"2012","unstructured":"Quan, E., et al.: A comprehensive comparison of IMRT and VMAT plan quality for prostate cancer treatment. Int. J. Radiat. Oncol. Biol. Phys. 83, 1169\u201378 (2012)","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"37_CR14","doi-asserted-by":"crossref","unstructured":"Ronneberger, O., Fischer, P., Brox, T.: U-net: convolutional networks for biomedical image segmentation. In: MICCAI, pp. 234\u2013241 (2015)","DOI":"10.1007\/978-3-319-24574-4_28"},{"key":"37_CR15","doi-asserted-by":"crossref","unstructured":"Sudre, C.H., Li, W., Vercauteren, T., Ourselin, S., Jorge Cardoso, M.: Generalised dice overlap as a deep learning loss function for highly unbalanced segmentations. In: Deep Learning in Medical Image Analysis and Multimodal Learning for Clinical Decision Support, pp. 240\u2013248 (2017)","DOI":"10.1007\/978-3-319-67558-9_28"},{"issue":"3","key":"37_CR16","doi-asserted-by":"publisher","first-page":"S44","DOI":"10.1016\/j.ijrobp.2020.07.2157","volume":"108","author":"V Vasudevan","year":"2020","unstructured":"Vasudevan, V., Huang, C., Simiele, E., Yu, L., Xing, L., Schuler, E.: Combining monte carlo with deep learning: Predicting high-resolution, low-noise dose distributions using a generative adversarial network for fast and precise monte carlo simulations. Int. J. Radiat. Oncol. Biol. Phys. 108(3), S44\u2013S45 (2020)","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"issue":"4","key":"37_CR17","doi-asserted-by":"publisher","first-page":"600","DOI":"10.1109\/TIP.2003.819861","volume":"13","author":"Z Wang","year":"2004","unstructured":"Wang, Z., Bovik, A.C., Sheikh, H.R., Simoncelli, E.P.: Image quality assessment: from error visibility to structural similarity. IEEE Trans. Image Process. 13(4), 600\u2013612 (2004)","journal-title":"IEEE Trans. Image Process."},{"issue":"5","key":"37_CR18","doi-asserted-by":"publisher","first-page":"1647","DOI":"10.1118\/1.2721657","volume":"34","author":"M Wendling","year":"2007","unstructured":"Wendling, M., et al.: A fast algorithm for gamma evaluation in 3D. Med. Phys. 34(5), 1647\u20131654 (2007)","journal-title":"Med. Phys."},{"issue":"1","key":"37_CR19","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1109\/TCI.2016.2644865","volume":"3","author":"H Zhao","year":"2016","unstructured":"Zhao, H., Gallo, O., Frosio, I., Kautz, J.: Loss functions for image restoration with neural networks. IEEE Trans. Comput. Imaging 3(1), 47\u201357 (2016)","journal-title":"IEEE Trans. Comput. Imaging"}],"container-title":["Lecture Notes in Computer Science","Information Processing in Medical Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-031-34048-2_37","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,6,7]],"date-time":"2023-06-07T12:08:01Z","timestamp":1686139681000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/978-3-031-34048-2_37"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023]]},"ISBN":["9783031340475","9783031340482"],"references-count":19,"URL":"https:\/\/doi.org\/10.1007\/978-3-031-34048-2_37","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"type":"print","value":"0302-9743"},{"type":"electronic","value":"1611-3349"}],"subject":[],"published":{"date-parts":[[2023]]},"assertion":[{"value":"8 June 2023","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}},{"value":"IPMI","order":1,"name":"conference_acronym","label":"Conference Acronym","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"International Conference on Information Processing in Medical Imaging","order":2,"name":"conference_name","label":"Conference Name","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"San Carlos de Bariloche","order":3,"name":"conference_city","label":"Conference City","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Argentina","order":4,"name":"conference_country","label":"Conference Country","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2023","order":5,"name":"conference_year","label":"Conference Year","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"12 June 2023","order":7,"name":"conference_start_date","label":"Conference Start Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"16 June 2023","order":8,"name":"conference_end_date","label":"Conference End Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"ipmi2023","order":10,"name":"conference_id","label":"Conference ID","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Double-blind","order":1,"name":"type","label":"Type","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"CMT","order":2,"name":"conference_management_system","label":"Conference Management System","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"169","order":3,"name":"number_of_submissions_sent_for_review","label":"Number of Submissions Sent for Review","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"63","order":4,"name":"number_of_full_papers_accepted","label":"Number of Full Papers Accepted","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"0","order":5,"name":"number_of_short_papers_accepted","label":"Number of Short Papers Accepted","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"37% - The value is computed by the equation \"Number of Full Papers Accepted \/ Number of Submissions Sent for Review * 100\" and then rounded to a whole number.","order":6,"name":"acceptance_rate_of_full_papers","label":"Acceptance Rate of Full Papers","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"3","order":7,"name":"average_number_of_reviews_per_paper","label":"Average Number of Reviews per Paper","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"4","order":8,"name":"average_number_of_papers_per_reviewer","label":"Average Number of Papers per Reviewer","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"Yes","order":9,"name":"external_reviewers_involved","label":"External Reviewers Involved","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}}]}}