{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,14]],"date-time":"2025-12-14T15:59:09Z","timestamp":1765727949925,"version":"3.40.3"},"publisher-location":"Cham","reference-count":41,"publisher":"Springer Nature Switzerland","isbn-type":[{"type":"print","value":"9783031525230"},{"type":"electronic","value":"9783031525247"}],"license":[{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024]]},"DOI":"10.1007\/978-3-031-52524-7_10","type":"book-chapter","created":{"date-parts":[[2024,1,23]],"date-time":"2024-01-23T05:35:04Z","timestamp":1705988104000},"page":"136-148","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["A Review of\u00a0Wearable Sensor Patches for\u00a0Patient Monitoring"],"prefix":"10.1007","author":[{"given":"S\u00f3nia","family":"Santos","sequence":"first","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6079-1105","authenticated-orcid":false,"given":"Maria Pedro","family":"Guarino","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1679-6002","authenticated-orcid":false,"given":"Sandra","family":"Neves","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2232-1839","authenticated-orcid":false,"given":"Nuno Vieira","family":"Lopes","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2024,1,24]]},"reference":[{"unstructured":"Braz\u00e3o, M. da Luz, N\u00f3brega, S., Bebiano, G., Carvalho, E.: Atividade dos Servi\u00e7os de Urg\u00eancia Hospitalares. Medicina Interna 23(3), 8\u201314 (2016)","key":"10_CR1"},{"doi-asserted-by":"crossref","unstructured":"Definition of Emergency Medicine: Ann. Emerg. Med. 52(2), 189\u2013190 (2008)","key":"10_CR2","DOI":"10.1016\/j.annemergmed.2008.05.029"},{"issue":"5","key":"10_CR3","doi-asserted-by":"publisher","first-page":"442","DOI":"10.1111\/j.1742-6723.2010.01322.x","volume":"22","author":"A Gedmintas","year":"2010","unstructured":"Gedmintas, A., Bost, N., Keijzers, G., Green, D., Lind, J.: Emergency care workload units: a novel tool to compare emergency department activity. EMA - Emerg. Med. Australas. 22(5), 442\u2013448 (2010)","journal-title":"EMA - Emerg. Med. Australas."},{"issue":"3","key":"10_CR4","doi-asserted-by":"publisher","first-page":"850","DOI":"10.4338\/ACI-2016-03-R-0042","volume":"7","author":"TC Lu","year":"2016","unstructured":"Lu, T.C., Fu, C.M., Ma, M.H., Fang, C.C., Turner, A.M.: Healthcare applications of smart watches. A Syst. Rev. Appl. Clin. Inf. 7(3), 850\u2013869 (2016)","journal-title":"A Syst. Rev. Appl. Clin. Inf."},{"key":"10_CR5","doi-asserted-by":"publisher","first-page":"269","DOI":"10.1016\/j.jbi.2016.09.001","volume":"63","author":"B Reeder","year":"2016","unstructured":"Reeder, B., David, A.: Health at hand: a systematic review of smart watch uses for health and wellness. J. Biomed. Inform. 63, 269\u2013276 (2016)","journal-title":"J. Biomed. Inform."},{"doi-asserted-by":"crossref","unstructured":"Jachymek, M., et al.: Wristbands in home-based rehabilitation-validation of heart rate measurement. Sensors 22(1) (2021)","key":"10_CR6","DOI":"10.3390\/s22010060"},{"key":"10_CR7","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1136\/bmjinnov-2019-000354","volume":"6","author":"S Soon","year":"2020","unstructured":"Soon, S., Svavarsdottir, H., Downey, C., Jayne, D.: Wearable devices for remote vital signs monitoring in the outpatient setting: an overview of the field. BMJ Innov. 6, 55\u201371 (2020)","journal-title":"BMJ Innov."},{"doi-asserted-by":"crossref","unstructured":"Neves, S., Oliveira, V., Guarino, M.: Using co-design methods to develop a patient monitoring system in hospital emergency care to support patient safety. In: 13th International Conference on Applied Human Factors and Ergonomics (AHFE 2022). AHFE International, New York (2022)","key":"10_CR8","DOI":"10.54941\/ahfe1001405"},{"unstructured":"BioBeat Product Homepage. https:\/\/www.bio-beat.com\/products. Accessed 1 Apr 2023","key":"10_CR9"},{"unstructured":"BioBeat Platform User Guide. https:\/\/www.mindtecstore.com\/mediafiles\/Sonstiges\/Shop\/Biobeat\/Biobeat_User_Manual_July2020.pdf. Accessed 1 Apr 2023","key":"10_CR10"},{"key":"10_CR11","doi-asserted-by":"publisher","DOI":"10.3389\/fmed.2021.693926","volume":"8","author":"E Kachel","year":"2021","unstructured":"Kachel, E., et al.: A pilot study of blood pressure monitoring after cardiac surgery using a wearable, non-invasive sensor. Front. Med. 8, 693926 (2021)","journal-title":"Front. Med."},{"key":"10_CR12","doi-asserted-by":"publisher","DOI":"10.3389\/fphys.2022.911544","volume":"13","author":"D Nachman","year":"2022","unstructured":"Nachman, D., et al.: Influence of sex, BMI, and skin color on the accuracy of non-invasive cuffless photoplethysmography-based blood pressure measurements. Front. Physiol. 13, 911544 (2022)","journal-title":"Front. Physiol."},{"key":"10_CR13","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1038\/s43856-022-00090-y","volume":"2","author":"Y Gepner","year":"2022","unstructured":"Gepner, Y., et al.: Utilizing wearable sensors for continuous and highly-sensitive monitoring of reactions to the BNT162b2 mRNA COVID-19 vaccine. Commun. Med. 2, 27 (2022)","journal-title":"Commun. Med."},{"doi-asserted-by":"crossref","unstructured":"Sharabi, I., et al.: Assessing the use of a noninvasive monitoring system providing multiple cardio-pulmonary parameters following revascularization in STEMI patients. Digit. Health 9 (2023)","key":"10_CR14","DOI":"10.1177\/20552076231179014"},{"key":"10_CR15","doi-asserted-by":"publisher","first-page":"519","DOI":"10.3389\/fphys.2023.1138647","volume":"14","author":"A Eisenkraft","year":"2023","unstructured":"Eisenkraft, A., et al.: Developing a real-time detection tool and an early warning score using a continuous wearable multi-parameter monitor. Front. Physiol. 14, 519 (2023)","journal-title":"Front. Physiol."},{"doi-asserted-by":"crossref","unstructured":"Eisenkraft, A., et al.: Clinical validation of a wearable respiratory rate device: a brief report. Chronic Respir. Disease 20 (2023)","key":"10_CR16","DOI":"10.1177\/14799731231198865"},{"doi-asserted-by":"crossref","unstructured":"Eisenkraft, A., et al.: Developing a real-time detection tool and an early warning score using a continuous wearable multi-parameter monitor. Front. Physiol. 14 (2023)","key":"10_CR17","DOI":"10.3389\/fphys.2023.1138647"},{"issue":"6","key":"10_CR18","doi-asserted-by":"publisher","first-page":"e36066","DOI":"10.2196\/36066","volume":"6","author":"E Itelman","year":"2022","unstructured":"Itelman, E., et al.: Assessing the usability of a novel wearable remote patient monitoring device for the early detection of in-hospital patient deterioration: observational study. JMIR Formative Res. 6(6), e36066 (2022)","journal-title":"JMIR Formative Res."},{"unstructured":"Sensium System Webpage. https:\/\/www.tsc-group.com\/connected-care\/products\/sensium\/. Accessed 1 Apr 2023","key":"10_CR19"},{"issue":"1","key":"10_CR20","doi-asserted-by":"publisher","first-page":"183","DOI":"10.1186\/s40814-020-00709-8","volume":"6","author":"CL Downey","year":"2020","unstructured":"Downey, C.L., et al.: Trial of remote continuous versus intermittent NEWS monitoring after major surgery (TRaCINg): a feasibility randomised controlled trial. Pilot Feasibility Stud. 6(1), 183 (2020)","journal-title":"Pilot Feasibility Stud."},{"issue":"2","key":"10_CR21","doi-asserted-by":"publisher","DOI":"10.2196\/27866","volume":"6","author":"M Joshi","year":"2022","unstructured":"Joshi, M., et al.: Perceptions on the use of wearable sensors and continuous monitoring in surgical patients: interview study among surgical staff. JMIR Formative Res. 6(2), e27866 (2022)","journal-title":"JMIR Formative Res."},{"issue":"1","key":"10_CR22","doi-asserted-by":"publisher","DOI":"10.2196\/18836","volume":"4","author":"M Joshi","year":"2021","unstructured":"Joshi, M., et al.: Short-term wearable sensors for in-hospital medical and surgical patients: mixed methods analysis of patient perspectives. JMIR Perioperative Med. 4(1), e18836 (2021)","journal-title":"JMIR Perioperative Med."},{"issue":"8","key":"10_CR23","doi-asserted-by":"publisher","DOI":"10.1136\/bmjopen-2019-031150","volume":"9","author":"C Downey","year":"2019","unstructured":"Downey, C., Ng, S., Jayne, D., Wong, D.: Reliability of a wearable wireless patch for continuous remote monitoring of vital signs in patients recovering from major surgery: a clinical validation study from the TRaCINg trial. BMJ Open 9(8), e031150 (2019)","journal-title":"BMJ Open"},{"issue":"7","key":"10_CR24","doi-asserted-by":"publisher","first-page":"728","DOI":"10.1080\/13696998.2020.1747474","volume":"23","author":"M Javanbakht","year":"2020","unstructured":"Javanbakht, M., et al.: Cost utility analysis of continuous and intermittent versus intermittent vital signs monitoring in patients admitted to surgical wards. J. Med. Econ. 23(7), 728\u2013736 (2020)","journal-title":"J. Med. Econ."},{"unstructured":"VitalConnect Homepage. https:\/\/vitalconnect.com\/. Accessed 1 Apr 2023","key":"10_CR25"},{"doi-asserted-by":"crossref","unstructured":"Selvaraj, N., Nallathambi, G., Moghadam, R., Aga, A.: Disposable wireless patch sensor for continuous remote patient monitoring. In: Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society, pp. 1632\u20131635 (2018)","key":"10_CR26","DOI":"10.1109\/EMBC.2018.8512569"},{"doi-asserted-by":"crossref","unstructured":"Rajbhandary, P. L., Nallathambi, G.: Feasibility of continuous monitoring of core body temperature using chest-worn patch sensor. In: Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society, pp. 4652\u20134655 (2020)","key":"10_CR27","DOI":"10.1109\/EMBC44109.2020.9175579"},{"doi-asserted-by":"crossref","unstructured":"Selvaraj, N., Nallathambi, G., Kettle, P.: A novel synthetic simulation platform for validation of breathing rate measurement. In: 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Honolulu, pp. 1177\u20131180 (2018)","key":"10_CR28","DOI":"10.1109\/EMBC.2018.8512352"},{"issue":"9","key":"10_CR29","doi-asserted-by":"publisher","first-page":"e27547","DOI":"10.2196\/27547","volume":"23","author":"C Morgado Areia","year":"2021","unstructured":"Morgado Areia, C., et al.: A chest patch for continuous vital sign monitoring: clinical validation study during movement and controlled hypoxia. J. Med. Internet Res. 23(9), e27547 (2021)","journal-title":"J. Med. Internet Res."},{"issue":"1","key":"10_CR30","doi-asserted-by":"publisher","first-page":"e30863","DOI":"10.2196\/30863","volume":"6","author":"ME Haveman","year":"2022","unstructured":"Haveman, M.E., et al.: Continuous monitoring of vital signs with wearable sensors during daily life activities: validation study. JMIR Formative Res. 6(1), e30863 (2022)","journal-title":"JMIR Formative Res."},{"unstructured":"Biosensor BX100 Product Page. https:\/\/www.philips.ca\/healthcare\/product\/HC989803203011\/biosensor-bx100-wearable-remote-measurement-device. Accessed 1 Apr 2023","key":"10_CR31"},{"key":"10_CR32","doi-asserted-by":"publisher","first-page":"103","DOI":"10.2147\/OAEM.S198842","volume":"11","author":"T Li","year":"2019","unstructured":"Li, T., Divatia, S., McKittrick, J., Moss, J., Hijnen, N.M., Becker, L.B.: A pilot study of respiratory rate derived from a wearable biosensor compared with capnography in emergency department patients. Open Access Emer. Med. 11, 103\u2013108 (2019)","journal-title":"Open Access Emer. Med."},{"issue":"5","key":"10_CR33","doi-asserted-by":"publisher","first-page":"1449","DOI":"10.1007\/s10877-021-00785-y","volume":"36","author":"N Kant","year":"2022","unstructured":"Kant, N., et al.: Continuous vital sign monitoring using a wearable patch sensor in obese patients: a validation study in a clinical setting. J. Clin. Monit. Comput. 36(5), 1449\u20131459 (2022)","journal-title":"J. Clin. Monit. Comput."},{"key":"10_CR34","doi-asserted-by":"publisher","first-page":"63684","DOI":"10.1109\/ACCESS.2022.3182704","volume":"10","author":"A Bhattarai","year":"2022","unstructured":"Bhattarai, A., Peng, D., Payne, J., Sharif, H.: Adaptive partition of ECG diagnosis between cloud and wearable sensor net using open-loop and closed-loop switch mode. IEEE Access 10, 63684\u201363697 (2022)","journal-title":"IEEE Access"},{"doi-asserted-by":"crossref","unstructured":"Miller, K., et al.: Deployment of a wearable biosensor system in the emergency department: a technical feasibility study. In: Proceedings of the Annual Hawaii International Conference on System Sciences, pp. 3567\u20133572 (2021)","key":"10_CR35","DOI":"10.24251\/HICSS.2021.433"},{"unstructured":"Preventice Solutions Home Page. https:\/\/www.preventicesolutions.com\/us\/en\/home.html. Accessed 10 Apr 2023","key":"10_CR36"},{"issue":"10","key":"10_CR37","doi-asserted-by":"publisher","first-page":"559","DOI":"10.4330\/wjc.v8.i10.559","volume":"8","author":"CJ Bruce","year":"2016","unstructured":"Bruce, C.J., et al.: Remote electrocardiograph monitoring using a novel adhesive strip sensor: a pilot study. World J. Cardiol. 8(10), 559\u2013565 (2016)","journal-title":"World J. Cardiol."},{"issue":"6","key":"10_CR38","doi-asserted-by":"publisher","first-page":"677","DOI":"10.1111\/cts.12673","volume":"12","author":"ES Izmailova","year":"2019","unstructured":"Izmailova, E.S., et al.: Continuous monitoring using a wearable device detects activity-induced heart rate changes after administration of amphetamine. Clin. Transl. Sci. 12(6), 677\u2013686 (2019)","journal-title":"Clin. Transl. Sci."},{"doi-asserted-by":"crossref","unstructured":"Teplitzky, B.A., McRoberts, M., Ghanbari, H.: Deep learning for comprehensive ECG annotation. Heart Rhythm 17(5 Pt B), 881\u2013888 (2020)","key":"10_CR39","DOI":"10.1016\/j.hrthm.2020.02.015"},{"unstructured":"1AX Biosensor Product Page. https:\/\/lifesignals.com\/wearable-biosensors\/1ax-biosensor\/. Accessed 10 Apr 2023","key":"10_CR40"},{"unstructured":"Multi-Vital ECG Sensor Product Page. https:\/\/www.vivalink.com\/wearable-ecg-monitor. Accessed 10 Apr 2023","key":"10_CR41"}],"container-title":["Lecture Notes of the Institute for Computer Sciences, Social Informatics and Telecommunications Engineering","Smart Objects and Technologies for Social Good"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-031-52524-7_10","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,1,23]],"date-time":"2024-01-23T05:36:25Z","timestamp":1705988185000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/978-3-031-52524-7_10"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024]]},"ISBN":["9783031525230","9783031525247"],"references-count":41,"URL":"https:\/\/doi.org\/10.1007\/978-3-031-52524-7_10","relation":{},"ISSN":["1867-8211","1867-822X"],"issn-type":[{"type":"print","value":"1867-8211"},{"type":"electronic","value":"1867-822X"}],"subject":[],"published":{"date-parts":[[2024]]},"assertion":[{"value":"24 January 2024","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}},{"value":"GOODTECHS","order":1,"name":"conference_acronym","label":"Conference Acronym","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"International Conference on Smart Objects and Technologies for Social Good","order":2,"name":"conference_name","label":"Conference Name","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Leiria","order":3,"name":"conference_city","label":"Conference City","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Portugal","order":4,"name":"conference_country","label":"Conference Country","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2023","order":5,"name":"conference_year","label":"Conference Year","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"18 October 2023","order":7,"name":"conference_start_date","label":"Conference Start Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"20 October 2023","order":8,"name":"conference_end_date","label":"Conference End Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"goodtechs2023","order":10,"name":"conference_id","label":"Conference ID","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Single-blind","order":1,"name":"type","label":"Type","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"Confy +","order":2,"name":"conference_management_system","label":"Conference Management System","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"30","order":3,"name":"number_of_submissions_sent_for_review","label":"Number of Submissions Sent for Review","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"13","order":4,"name":"number_of_full_papers_accepted","label":"Number of Full Papers Accepted","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"0","order":5,"name":"number_of_short_papers_accepted","label":"Number of Short Papers Accepted","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"43% - The value is computed by the equation \"Number of Full Papers Accepted \/ Number of Submissions Sent for Review * 100\" and then rounded to a whole number.","order":6,"name":"acceptance_rate_of_full_papers","label":"Acceptance Rate of Full Papers","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"3","order":7,"name":"average_number_of_reviews_per_paper","label":"Average Number of Reviews per Paper","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"3","order":8,"name":"average_number_of_papers_per_reviewer","label":"Average Number of Papers per Reviewer","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"Yes","order":9,"name":"external_reviewers_involved","label":"External Reviewers Involved","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}}]}}