{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,4]],"date-time":"2025-12-04T10:09:44Z","timestamp":1764842984210,"version":"3.40.4"},"publisher-location":"Cham","reference-count":31,"publisher":"Springer Nature Switzerland","isbn-type":[{"value":"9783031855740","type":"print"},{"value":"9783031855757","type":"electronic"}],"license":[{"start":{"date-parts":[[2025,1,1]],"date-time":"2025-01-01T00:00:00Z","timestamp":1735689600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,1,1]],"date-time":"2025-01-01T00:00:00Z","timestamp":1735689600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2025]]},"DOI":"10.1007\/978-3-031-85575-7_12","type":"book-chapter","created":{"date-parts":[[2025,4,22]],"date-time":"2025-04-22T11:27:38Z","timestamp":1745321258000},"page":"190-200","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["A Flexible IMU-Based Unit for Validation Studies: A Step Counting Application"],"prefix":"10.1007","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8266-9346","authenticated-orcid":false,"given":"Alessandra","family":"Angelucci","sequence":"first","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0009-0005-1184-5898","authenticated-orcid":false,"given":"Lorenzo","family":"Barbieri","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8461-0089","authenticated-orcid":false,"given":"Sara","family":"Caramaschi","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0009-0005-7266-8469","authenticated-orcid":false,"given":"Clarysse A.","family":"Sarmiento","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0009-0007-3771-5519","authenticated-orcid":false,"given":"Virginia","family":"Sekules","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2950-0231","authenticated-orcid":false,"given":"Andrea","family":"Aliverti","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2025,4,23]]},"reference":[{"key":"12_CR1","doi-asserted-by":"crossref","unstructured":"Angelucci, A., Canali, S., Aliverti, A.: Digital technologies for step counting: between promises of reliability and risks of reductionism. Front Digit Health. 5 (2023)","DOI":"10.3389\/fdgth.2023.1330189"},{"key":"12_CR2","doi-asserted-by":"publisher","unstructured":"Greco, M., et al.: Wearable health technology for preoperative risk assessment in elderly patients: the WELCOME study. Diagnostics 13 (2023). https:\/\/doi.org\/10.3390\/diagnostics13040630","DOI":"10.3390\/diagnostics13040630"},{"key":"12_CR3","doi-asserted-by":"publisher","unstructured":"Angelucci, A., et al.: Fitbit data to assess functional capacity in patients before elective surgery: pilot prospective observational study. J. Med. Internet Res. 25 (2023). https:\/\/doi.org\/10.2196\/42815","DOI":"10.2196\/42815"},{"key":"12_CR4","doi-asserted-by":"publisher","first-page":"414","DOI":"10.1109\/THMS.2020.2984181","volume":"50","author":"W Qi","year":"2020","unstructured":"Qi, W., Su, H., Aliverti, A.: A smartphone-based adaptive recognition and real-time monitoring system for human activities. IEEE Trans. Hum. Mach. Syst. 50, 414\u2013423 (2020). https:\/\/doi.org\/10.1109\/THMS.2020.2984181","journal-title":"IEEE Trans. Hum. Mach. Syst."},{"key":"12_CR5","doi-asserted-by":"publisher","first-page":"2555","DOI":"10.1109\/JSEN.2017.2786587","volume":"18","author":"AR Anwary","year":"2018","unstructured":"Anwary, A.R., Yu, H., Vassallo, M.: Optimal foot location for placing wearable IMU sensors and automatic feature extraction for gait analysis. IEEE Sens. J. 18, 2555\u20132567 (2018). https:\/\/doi.org\/10.1109\/JSEN.2017.2786587","journal-title":"IEEE Sens. J."},{"key":"12_CR6","doi-asserted-by":"publisher","unstructured":"Jiang, X., Chu, K.H.T., Menon, C.: An easy-to-use wearable step counting device for slow walking using ankle force myography. In: 2017 IEEE International Conference on Systems, Man, and Cybernetics, SMC 2017. 2017-January, pp. 2219\u20132224 (2017). https:\/\/doi.org\/10.1109\/SMC.2017.8122950","DOI":"10.1109\/SMC.2017.8122950"},{"key":"12_CR7","doi-asserted-by":"publisher","unstructured":"Aliverti, A., Evangelisti, M., Angelucci, A.: Wearable tech for long-distance runners (2022). https:\/\/doi.org\/10.1007\/978-3-662-65064-6_10","DOI":"10.1007\/978-3-662-65064-6_10"},{"key":"12_CR8","doi-asserted-by":"publisher","unstructured":"Civeriati, V., et al.: A sensorized insole to estimate ground reaction forces and center of pressure during gait. In: 2024 IEEE International Workshop on Sport, Technology and Research (STAR), pp. 21\u201325 (2024). https:\/\/doi.org\/10.1109\/STAR62027.2024.10636002","DOI":"10.1109\/STAR62027.2024.10636002"},{"key":"12_CR9","doi-asserted-by":"publisher","unstructured":"Cristiano, A., Sanna, A., Trojaniello, D.: Validity of a smart-glasses-based step-count measure during simulated free-living conditions. Information 11, 404 (2020). https:\/\/doi.org\/10.3390\/INFO11090404","DOI":"10.3390\/INFO11090404"},{"key":"12_CR10","doi-asserted-by":"publisher","unstructured":"Kristiansson, E., Fridolfsson, J., Arvidsson, D., Holm\u00e4ng, A., B\u00f6rjesson, M., Andersson-Hall, U.: Validation of Oura ring energy expenditure and steps in laboratory and free-living. BMC Med. Res. Methodol. 23 (2023). https:\/\/doi.org\/10.1186\/s12874-023-01868-x","DOI":"10.1186\/s12874-023-01868-x"},{"key":"12_CR11","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3390\/s21030814","volume":"21","author":"A Angelucci","year":"2021","unstructured":"Angelucci, A., et al.: Smart textiles and sensorized garments for physiological monitoring: a review of available solutions and techniques. Sensors (Switzerland) 21, 1\u201323 (2021). https:\/\/doi.org\/10.3390\/s21030814","journal-title":"Sensors (Switzerland)"},{"key":"12_CR12","doi-asserted-by":"publisher","unstructured":"Angelucci, A., Kuller, D., Aliverti, A.: A home telemedicine system for continuous respiratory monitoring. IEEE J. Biomed. Health Inform. 25 (2021). https:\/\/doi.org\/10.1109\/JBHI.2020.3012621","DOI":"10.1109\/JBHI.2020.3012621"},{"key":"12_CR13","doi-asserted-by":"publisher","unstructured":"Prakash, J., Yang, Z., Wei, Y.L., Choudhury, R.R.: STEAR: robust step counting from earables. In: Proceedings of the 1st International Workshop on Earable Computing, EarComp 2019, pp. 36\u201341. Association for Computing Machinery, Inc (2019). https:\/\/doi.org\/10.1145\/3345615.3361133","DOI":"10.1145\/3345615.3361133"},{"key":"12_CR14","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1016\/j.pulmoe.2019.11.006","volume":"26","author":"A Angelucci","year":"2020","unstructured":"Angelucci, A., Aliverti, A.: Telemonitoring systems for respiratory patients: technological aspects. Pulmonology 26, 221\u2013232 (2020). https:\/\/doi.org\/10.1016\/j.pulmoe.2019.11.006","journal-title":"Pulmonology"},{"key":"12_CR15","doi-asserted-by":"publisher","unstructured":"Mass\u00e9, F., Gonzenbach, R.R., Arami, A., Paraschiv-Ionescu, A., Luft, A.R., Aminian, K.: Improving activity recognition using a wearable barometric pressure sensor in mobility-impaired stroke patients. J. Neuroeng. Rehabil. 12 (2015). https:\/\/doi.org\/10.1186\/s12984-015-0060-2","DOI":"10.1186\/s12984-015-0060-2"},{"key":"12_CR16","doi-asserted-by":"publisher","unstructured":"Chen, J.L., et al.: Plantar pressure-based insole gait monitoring techniques for diseases monitoring and analysis: a review (2022). https:\/\/doi.org\/10.1002\/admt.202100566","DOI":"10.1002\/admt.202100566"},{"key":"12_CR17","doi-asserted-by":"publisher","first-page":"410","DOI":"10.70252\/IZMD1804","volume":"13","author":"J Montes","year":"2020","unstructured":"Montes, J., Tandy, R., Young, J., Lee, S.-P., Navalta, J.W.: Step count reliability and validity of five wearable technology devices while walking and jogging in both a free motion setting and on a treadmill. Int. J. Exerc. Sci. 13, 410\u2013426 (2020)","journal-title":"Int. J. Exerc. Sci."},{"key":"12_CR18","doi-asserted-by":"publisher","unstructured":"Moore, C.C., McCullough, A.K., Aguiar, E.J., Ducharme, S.W., Tudor-Locke, C.: Toward harmonized treadmill-based validation of step-counting wearable technologies: a scoping review (2020). https:\/\/doi.org\/10.1123\/jpah.2019-0205","DOI":"10.1123\/jpah.2019-0205"},{"key":"12_CR19","doi-asserted-by":"publisher","first-page":"2020","DOI":"10.1001\/JAMA.2018.14854","volume":"320","author":"KL Piercy","year":"2018","unstructured":"Piercy, K.L., et al.: The physical activity guidelines for Americans. JAMA 320, 2020\u20132028 (2018). https:\/\/doi.org\/10.1001\/JAMA.2018.14854","journal-title":"JAMA"},{"key":"12_CR20","doi-asserted-by":"publisher","unstructured":"Angelucci, A., et al.: A wireless body sensor network for cardiorespiratory monitoring during cycling. In: 2023 IEEE International Workshop on Sport, Technology and Research (STAR), pp. 1\u20134 (2023). https:\/\/doi.org\/10.1109\/STAR58331.2023.10302438","DOI":"10.1109\/STAR58331.2023.10302438"},{"key":"12_CR21","unstructured":"Bangle.js 2 \u2013 Espruino. https:\/\/www.espruino.com\/Bangle.js2. Accessed 28 June 2024"},{"key":"12_CR22","doi-asserted-by":"publisher","unstructured":"Schaffarczyk, M., Rogers, B., Reer, R., Gronwald, T.: Validity of the polar H10 sensor for heart rate variability analysis during resting state and incremental exercise in recreational men and women. Sensors 22 (2022). https:\/\/doi.org\/10.3390\/s22176536","DOI":"10.3390\/s22176536"},{"key":"12_CR23","unstructured":"Polar H10|Polar Global. https:\/\/www.polar.com\/en\/sensors\/h10-heart-rate-sensor. Accessed 28 June 2024"},{"key":"12_CR24","doi-asserted-by":"publisher","first-page":"119","DOI":"10.2114\/JPA2.30.119","volume":"30","author":"J Park","year":"2011","unstructured":"Park, J., Ishikawa-Takata, K., Tanaka, S., Mekata, Y., Tabata, I.: Effects of walking speed and step frequency on estimation of physical activity using accelerometers. J. Physiol. Anthropol. 30, 119\u2013127 (2011). https:\/\/doi.org\/10.2114\/JPA2.30.119","journal-title":"J. Physiol. Anthropol."},{"key":"12_CR25","doi-asserted-by":"publisher","unstructured":"Angelucci, A., Camuncoli, F., Galli, M., Aliverti, A.: A wearable system for respiratory signal filtering based on activity: a preliminary validation. In: 2022 IEEE International Workshop on Sport, Technology and Research, STAR 2022 - Proceedings (2022). https:\/\/doi.org\/10.1109\/STAR53492.2022.9860001","DOI":"10.1109\/STAR53492.2022.9860001"},{"key":"12_CR26","doi-asserted-by":"publisher","unstructured":"Angelucci, A., Aliverti, A.: An IMU-based wearable system for respiratory rate estimation in static and dynamic conditions. Cardiovasc Eng Technol. 1\u201313 (2023). https:\/\/doi.org\/10.1007\/S13239-023-00657-3\/FIGURES\/8","DOI":"10.1007\/S13239-023-00657-3\/FIGURES\/8"},{"key":"12_CR27","doi-asserted-by":"publisher","unstructured":"Angelucci, A., Bernasconi, S., D\u2019Andrea, M., Contini, M., Gugliandolo, P., Agostoni, P., Aliverti, A.: Integration of a body sensor network of wearable devices for cardio-respiratory monitoring. In: 2023 45th Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC), pp. 1\u20134 (2023). https:\/\/doi.org\/10.1109\/EMBC40787.2023.10340495","DOI":"10.1109\/EMBC40787.2023.10340495"},{"key":"12_CR28","doi-asserted-by":"publisher","first-page":"80308","DOI":"10.1109\/ACCESS.2024.3408904","volume":"12","author":"A Angelucci","year":"2024","unstructured":"Angelucci, A., Birettoni, F., Bufalari, A., Aliverti, A.: Validation of a wearable system for respiratory rate monitoring in dogs. IEEE Access. 12, 80308\u201380316 (2024). https:\/\/doi.org\/10.1109\/ACCESS.2024.3408904","journal-title":"IEEE Access."},{"key":"12_CR29","doi-asserted-by":"publisher","unstructured":"Angelucci, A., Villamar, O.W.P., Agostoni, P., Aliverti, A.: Design and evaluation of a wearable single-lead ECG for continuous monitoring. In: 2023 IEEE International Conference on Metrology for Extended Reality, Artificial Intelligence and Neural Engineering (MetroXRAINE), pp. 80\u201385 (2023). https:\/\/doi.org\/10.1109\/MetroXRAINE58569.2023.10405813","DOI":"10.1109\/MetroXRAINE58569.2023.10405813"},{"key":"12_CR30","doi-asserted-by":"publisher","unstructured":"Bernasconi, S., Angelucci, A., Aliverti, A.: Evaluation of a new wearable device for indoor and outdoor environmental monitoring. In: 2024 IEEE International Workshop on Sport, Technology and Research (STAR), pp. 252\u2013257 (2024). https:\/\/doi.org\/10.1109\/STAR62027.2024.10635952","DOI":"10.1109\/STAR62027.2024.10635952"},{"key":"12_CR31","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/TIM.2024.3369136","volume":"73","author":"A Angelucci","year":"2024","unstructured":"Angelucci, A., et al.: A wearable device to monitor the partial pressure of transcutaneous carbon dioxide. IEEE Trans. Instrum. Meas.Instrum. Meas. 73, 1\u201312 (2024). https:\/\/doi.org\/10.1109\/TIM.2024.3369136","journal-title":"IEEE Trans. Instrum. Meas.Instrum. Meas."}],"container-title":["Lecture Notes of the Institute for Computer Sciences, Social Informatics and Telecommunications Engineering","Pervasive Computing Technologies for Healthcare"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-031-85575-7_12","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,22]],"date-time":"2025-04-22T11:27:42Z","timestamp":1745321262000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/978-3-031-85575-7_12"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025]]},"ISBN":["9783031855740","9783031855757"],"references-count":31,"URL":"https:\/\/doi.org\/10.1007\/978-3-031-85575-7_12","relation":{},"ISSN":["1867-8211","1867-822X"],"issn-type":[{"value":"1867-8211","type":"print"},{"value":"1867-822X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025]]},"assertion":[{"value":"23 April 2025","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}},{"value":"PervasiveHealth","order":1,"name":"conference_acronym","label":"Conference Acronym","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"International Conference on Pervasive Computing Technologies for Healthcare","order":2,"name":"conference_name","label":"Conference Name","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Heraklion, Crete","order":3,"name":"conference_city","label":"Conference City","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Greece","order":4,"name":"conference_country","label":"Conference Country","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2024","order":5,"name":"conference_year","label":"Conference Year","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"17 September 2024","order":7,"name":"conference_start_date","label":"Conference Start Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"18 September 2024","order":8,"name":"conference_end_date","label":"Conference End Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"18","order":9,"name":"conference_number","label":"Conference Number","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"ph2024","order":10,"name":"conference_id","label":"Conference ID","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"https:\/\/pervasivehealth.eai-conferences.org\/2024\/","order":11,"name":"conference_url","label":"Conference URL","group":{"name":"ConferenceInfo","label":"Conference Information"}}]}}