{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,16]],"date-time":"2026-11-16T08:59:56Z","timestamp":1794819596703,"version":"4.9.1"},"publisher-location":"Cham","reference-count":14,"publisher":"Springer Nature Switzerland","isbn-type":[{"value":"9783032059963","type":"print"},{"value":"9783032059970","type":"electronic"}],"license":[{"start":{"date-parts":[[2025,9,23]],"date-time":"2025-09-23T00:00:00Z","timestamp":1758585600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,9,23]],"date-time":"2025-09-23T00:00:00Z","timestamp":1758585600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026]]},"DOI":"10.1007\/978-3-032-05997-0_7","type":"book-chapter","created":{"date-parts":[[2025,9,22]],"date-time":"2025-09-22T07:23:43Z","timestamp":1758525823000},"page":"73-83","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Robustness and\u00a0Diagnostic Performance of\u00a0Super-Resolution Fetal Brain MRI"],"prefix":"10.1007","author":[{"ORCID":"https:\/\/orcid.org\/0009-0007-4115-4304","authenticated-orcid":false,"given":"Ema","family":"Masterl","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tina Vesnaver","family":"Vipotnik","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"\u017diga","family":"\u0160piclin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,9,23]]},"reference":[{"issue":"3","key":"7_CR1","doi-asserted-by":"publisher","first-page":"549","DOI":"10.1007\/s12021-023-09635-5","volume":"21","author":"T Ciceri","year":"2023","unstructured":"Ciceri, T., et al.: Geometric reliability of super-resolution reconstructed images from clinical fetal mri in the second trimester. Neuroinformatics 21(3), 549\u2013563 (2023)","journal-title":"Neuroinformatics"},{"key":"7_CR2","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2019.116324","volume":"206","author":"M Ebner","year":"2020","unstructured":"Ebner, M., et al.: An automated framework for localization, segmentation and super-resolution reconstruction of fetal brain mri. Neuroimage 206, 116324 (2020)","journal-title":"Neuroimage"},{"key":"7_CR3","first-page":"2962","volume":"28","author":"M Feurer","year":"2015","unstructured":"Feurer, M., Klein, A., Eggensperger, K., Springenberg, J., Blum, M., Hutter, F.: Efficient and robust automated machine learning. Adv. Neural Inf. Process. Syst. 28, 2962\u20132970 (2015)","journal-title":"Adv. Neural Inf. Process. Syst."},{"issue":"1","key":"7_CR4","doi-asserted-by":"publisher","first-page":"B2","DOI":"10.1016\/j.ajog.2018.04.039","volume":"219","author":"NS Fox","year":"2018","unstructured":"Fox, N.S., Monteagudo, A., Kuller, J.A., Craigo, S., Norton, M.E.: Mild fetal ventriculomegaly: diagnosis, evaluation, and management. Am. J. Obstet. Gynecol. 219(1), B2\u2013B9 (2018). https:\/\/doi.org\/10.1016\/j.ajog.2018.04.039","journal-title":"Am. J. Obstet. Gynecol."},{"issue":"8","key":"7_CR5","doi-asserted-by":"publisher","first-page":"1550","DOI":"10.1016\/j.media.2012.07.004","volume":"16","author":"M Kuklisova-Murgasova","year":"2012","unstructured":"Kuklisova-Murgasova, M., Quaghebeur, G., Rutherford, M.A., Hajnal, J.V., Schnabel, J.A.: Reconstruction of fetal brain mri with intensity matching and complete outlier removal. Med. Image Anal. 16(8), 1550\u20131564 (2012)","journal-title":"Med. Image Anal."},{"key":"7_CR6","doi-asserted-by":"publisher","unstructured":"Sanchez, T., et al.: Assessing data quality on fetal brain mri reconstruction: a multi-site and multi-rater study. In: International Workshop on Preterm, Perinatal and Paediatric Image Analysis, pp. 46\u201356. Springer, Heidelberg (2024). https:\/\/doi.org\/10.1007\/978-3-031-73260-7_5","DOI":"10.1007\/978-3-031-73260-7_5"},{"key":"7_CR7","doi-asserted-by":"crossref","unstructured":"Sanchez, T., et\u00a0al.: Biometry and volumetry in multi-centric fetal brain mri: assessing the bias of super-resolution reconstruction. medRxiv pp. 2024\u201309 (2024)","DOI":"10.1101\/2024.09.23.24313965"},{"key":"7_CR8","doi-asserted-by":"publisher","first-page":"460","DOI":"10.1016\/j.neuroimage.2017.04.004","volume":"155","author":"S Tourbier","year":"2017","unstructured":"Tourbier, S., et al.: Automated template-based brain localization and extraction for fetal brain MRI reconstruction. Neuroimage 155, 460\u2013472 (2017). https:\/\/doi.org\/10.1016\/j.neuroimage.2017.04.004","journal-title":"Neuroimage"},{"issue":"1147","key":"7_CR9","first-page":"20220071","volume":"96","author":"AU Uus","year":"2023","unstructured":"Uus, A.U., Egloff Collado, A., Roberts, T.A., Hajnal, J.V., Rutherford, M.A., Deprez, M.: Retrospective motion correction in foetal mri for clinical applications: existing methods, applications and integration into clinical practice. Br. J. Radiol. 96(1147), 20220071 (2023)","journal-title":"Br. J. Radiol."},{"key":"7_CR10","doi-asserted-by":"publisher","unstructured":"Uus, A.U., et al.: Combined quantitative t2* map and structural t2-weighted tissue-specific analysis for fetal brain mri: pilot automated pipeline. In: International Workshop on Preterm, Perinatal and Paediatric Image Analysis, pp. 28\u201338. Springer, Heidelberg (2023). https:\/\/doi.org\/10.1007\/978-3-031-45544-5_3","DOI":"10.1007\/978-3-031-45544-5_3"},{"key":"7_CR11","doi-asserted-by":"crossref","unstructured":"Uus, A.U., et\u00a0al.: Bounti: brain volumetry and automated parcellation for 3d fetal mri. bioRxiv (2023)","DOI":"10.7554\/eLife.88818"},{"key":"7_CR12","doi-asserted-by":"crossref","unstructured":"Uus, A.U., et\u00a0al.: Scanner-based real-time 3d brain+ body slice-to-volume reconstruction for t2-weighted 0.55 t low field fetal mri. medRxiv, pp. 2024\u201304 (2024)","DOI":"10.1101\/2024.04.22.24306177"},{"key":"7_CR13","doi-asserted-by":"publisher","unstructured":"Xu, J., et al.: Nesvor: implicit neural representation for slice-to-volume reconstruction in mri. IEEE Trans. Med. Imaging (2023). https:\/\/doi.org\/10.1109\/TMI.2023.3236216","DOI":"10.1109\/TMI.2023.3236216"},{"issue":"6","key":"7_CR14","doi-asserted-by":"publisher","first-page":"1707","DOI":"10.1109\/TMI.2023.3236216","volume":"42","author":"J Xu","year":"2023","unstructured":"Xu, J., Moyer, D., Gagoski, B., Iglesias, J.E., Grant, P.E., Golland, P., Adalsteinsson, E.: Nesvor: implicit neural representation for slice-to-volume reconstruction in mri. IEEE Trans. Med. Imaging 42(6), 1707\u20131719 (2023)","journal-title":"IEEE Trans. Med. Imaging"}],"container-title":["Lecture Notes in Computer Science","Perinatal, Preterm and Paediatric Image Analysis"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-032-05997-0_7","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T08:23:21Z","timestamp":1787041401000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/978-3-032-05997-0_7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,23]]},"ISBN":["9783032059963","9783032059970"],"references-count":14,"URL":"https:\/\/doi.org\/10.1007\/978-3-032-05997-0_7","relation":{"is-part-of":[{"id-type":"doi","id":"https:\/\/doi.org\/10.1007\/978-3-032-05997-0","asserted-by":"object"}]},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"value":"0302-9743","type":"print"},{"value":"1611-3349","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,23]]},"assertion":[{"value":"23 September 2025","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}},{"value":"PIPPI","order":1,"name":"conference_acronym","label":"Conference Acronym","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"International Workshop on Preterm, Perinatal and Paediatric Image Analysis","order":2,"name":"conference_name","label":"Conference Name","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Daejeon","order":3,"name":"conference_city","label":"Conference City","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Korea (Republic of)","order":4,"name":"conference_country","label":"Conference Country","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2025","order":5,"name":"conference_year","label":"Conference Year","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"27 September 2025","order":7,"name":"conference_start_date","label":"Conference Start Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"27 September 2025","order":8,"name":"conference_end_date","label":"Conference End Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"10","order":9,"name":"conference_number","label":"Conference Number","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"pippi2025","order":10,"name":"conference_id","label":"Conference ID","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"https:\/\/pippiworkshop.github.io\/","order":11,"name":"conference_url","label":"Conference URL","group":{"name":"ConferenceInfo","label":"Conference Information"}}]}}