{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,19]],"date-time":"2026-02-19T20:54:30Z","timestamp":1771534470788,"version":"3.50.1"},"publisher-location":"Cham","reference-count":23,"publisher":"Springer Nature Switzerland","isbn-type":[{"value":"9783032063281","type":"print"},{"value":"9783032063298","type":"electronic"}],"license":[{"start":{"date-parts":[[2025,9,27]],"date-time":"2025-09-27T00:00:00Z","timestamp":1758931200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,9,27]],"date-time":"2025-09-27T00:00:00Z","timestamp":1758931200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026]]},"DOI":"10.1007\/978-3-032-06329-8_3","type":"book-chapter","created":{"date-parts":[[2025,9,26]],"date-time":"2025-09-26T07:40:24Z","timestamp":1758872424000},"page":"23-32","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["DiffUS: Differentiable Ultrasound Rendering from\u00a0Volumetric Imaging"],"prefix":"10.1007","author":[{"given":"Noe","family":"Bertramo","sequence":"first","affiliation":[]},{"given":"Gabriel","family":"Duguey","sequence":"additional","affiliation":[]},{"given":"Vivek","family":"Gopalakrishnan","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2025,9,27]]},"reference":[{"issue":"5","key":"3_CR1","doi-asserted-by":"publisher","first-page":"S131","DOI":"10.1097\/01.CCM.0000260624.99430.22","volume":"35","author":"JE Aldrich","year":"2007","unstructured":"Aldrich, J.E.: Basic physics of ultrasound imaging. Crit. Care Med. 35(5), S131\u2013S137 (2007)","journal-title":"Crit. Care Med."},{"key":"3_CR2","doi-asserted-by":"publisher","DOI":"10.1016\/j.media.2023.102789","volume":"86","author":"B Billot","year":"2023","unstructured":"Billot, B., et al.: SynthSeg: segmentation of brain MRI scans of any contrast and resolution without retraining. Med. Image Anal. 86, 102789 (2023)","journal-title":"Med. Image Anal."},{"issue":"1","key":"3_CR3","doi-asserted-by":"publisher","first-page":"12340","DOI":"10.1038\/s41598-020-69298-z","volume":"10","author":"A Carr\u00e9","year":"2020","unstructured":"Carr\u00e9, A., et al.: Standardization of brain MR images across machines and protocols: bridging the gap for MRI-based radiomics. Sci. Rep. 10(1), 12340 (2020)","journal-title":"Sci. Rep."},{"key":"3_CR4","doi-asserted-by":"crossref","unstructured":"Chan, V., Perlas, A.: Basics of ultrasound imaging. Atlas Ultrasound-Guided Proced. Intervent. Pain Manage., 13\u201319 (2011)","DOI":"10.1007\/978-1-4419-1681-5_2"},{"issue":"6","key":"3_CR5","doi-asserted-by":"publisher","first-page":"2136","DOI":"10.1002\/mrm.26292","volume":"77","author":"J Chen","year":"2017","unstructured":"Chen, J., et al.: Measurement of bound and pore water t1 relaxation times in cortical bone using three-dimensional ultrashort echo time cones sequences. Magn. Reson. Med. 77(6), 2136\u20132145 (2017)","journal-title":"Magn. Reson. Med."},{"key":"3_CR6","doi-asserted-by":"publisher","unstructured":"Drew, Z., Haouimi, A., Murphy, A., et\u00a0al.: T1 values (1.5 t) (2025). https:\/\/doi.org\/10.53347\/rID-60740, https:\/\/radiopaedia.org\/articles\/60740, reference article, Radiopaedia.org. Accessed 25 Jun 2025","DOI":"10.53347\/rID-60740"},{"key":"3_CR7","doi-asserted-by":"crossref","unstructured":"Duelmer, F., Azampour, M.F., Navab, N.: UltraRay: full-path ray tracing for enhancing realism in ultrasound simulation (2025). https:\/\/arxiv.org\/abs\/2501.05828","DOI":"10.1007\/978-3-032-04937-7_62"},{"issue":"3","key":"3_CR8","doi-asserted-by":"publisher","first-page":"294","DOI":"10.1038\/s42256-023-00629-1","volume":"5","author":"C Gao","year":"2023","unstructured":"Gao, C., et al.: Synthetic data accelerates the development of generalizable learning-based algorithms for X-ray image analysis. Nat. Mach. Intell. 5(3), 294\u2013308 (2023)","journal-title":"Nat. Mach. Intell."},{"issue":"10","key":"3_CR9","doi-asserted-by":"publisher","first-page":"1739","DOI":"10.1109\/TMI.2010.2051680","volume":"29","author":"A Gholipour","year":"2010","unstructured":"Gholipour, A., Estroff, J.A., Warfield, S.K.: Robust super-resolution volume reconstruction from slice acquisitions: application to fetal brain MRI. IEEE Trans. Med. Imaging 29(10), 1739\u20131758 (2010)","journal-title":"IEEE Trans. Med. Imaging"},{"key":"3_CR10","unstructured":"Gopalakrishnan, V., et al.: Rapid patient-specific neural networks for intraoperative X-ray to volume registration. arXiv preprint arXiv:2503.16309 (2025)"},{"key":"3_CR11","doi-asserted-by":"crossref","unstructured":"Gopalakrishnan, V., Dey, N., Golland, P.: Intraoperative 2D\/3D image registration via differentiable X-ray rendering. In: Proceedings of the IEEE\/CVF Conference on Computer Vision and Pattern Recognition, pp. 11662\u201311672 (2024)","DOI":"10.1109\/CVPR52733.2024.01108"},{"key":"3_CR12","doi-asserted-by":"crossref","unstructured":"Gopalakrishnan, V., Golland, P.: Fast auto-differentiable digitally reconstructed radiographs for solving inverse problems in intraoperative imaging. In: Workshop on Clinical Image-Based Procedures, pp. 1\u201311. Springer (2022)","DOI":"10.1007\/978-3-031-23179-7_1"},{"issue":"10","key":"3_CR13","doi-asserted-by":"publisher","first-page":"1303","DOI":"10.7863\/jum.2007.26.10.1303","volume":"26","author":"J Huang","year":"2007","unstructured":"Huang, J., Triedman, J.K., Vasilyev, N.V., Suematsu, Y., Cleveland, R.O., Dupont, P.E.: Imaging artifacts of medical instruments in ultrasound-guided interventions. J. Ultrasound Med. 26(10), 1303\u20131322 (2007)","journal-title":"J. Ultrasound Med."},{"key":"3_CR14","unstructured":"Joarder, Y., Rahman, K.M., Mahi, F.F.: Uplifted tissue characterization and classification of fatty liver disease from ultrasound images. J. Image Process. Pattern Recogn. Progress 3 (2020)"},{"key":"3_CR15","doi-asserted-by":"crossref","unstructured":"Juvekar, P., et\u00a0al.: The brain resection multimodal imaging database (remind). The Cancer Imaging Archive (2023)","DOI":"10.1101\/2023.09.14.23295596"},{"issue":"12","key":"3_CR16","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0208820","volume":"13","author":"ZH Levine","year":"2018","unstructured":"Levine, Z.H., Peskin, A.P., Holmgren, A.D., Garboczi, E.J.: Preliminary X-ray CT investigation to link hounsfield unit measurements with the international system of units (SI). PLoS ONE 13(12), e0208820 (2018)","journal-title":"PLoS ONE"},{"key":"3_CR17","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2019.116094","volume":"202","author":"I Machado","year":"2019","unstructured":"Machado, I., et al.: Deformable MRI-ultrasound registration using correlation-based attribute matching for brain shift correction: Accuracy and generality in multi-site data. Neuroimage 202, 116094 (2019). https:\/\/doi.org\/10.1016\/j.neuroimage.2019.116094","journal-title":"Neuroimage"},{"issue":"1","key":"3_CR18","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1088\/0031-9155\/41\/1\/009","volume":"41","author":"U Schneider","year":"1996","unstructured":"Schneider, U., Pedroni, E., Lomax, A.: The calibration of CT hounsfield units for radiotherapy treatment planning. Phys. Med. Biol. 41(1), 111 (1996)","journal-title":"Phys. Med. Biol."},{"issue":"4","key":"3_CR19","doi-asserted-by":"publisher","first-page":"2288","DOI":"10.1121\/10.0002177","volume":"148","author":"BE Treeby","year":"2020","unstructured":"Treeby, B.E., Wise, E.S., Kuklis, F., Jaros, J., Cox, B.: Nonlinear ultrasound simulation in an axisymmetric coordinate system using a k-space pseudospectral method. J. Acoust. Soc. Am. 148(4), 2288\u20132300 (2020)","journal-title":"J. Acoust. Soc. Am."},{"issue":"7","key":"3_CR20","doi-asserted-by":"publisher","first-page":"1111","DOI":"10.1109\/TUFFC.2018.2827899","volume":"65","author":"TD Webb","year":"2018","unstructured":"Webb, T.D., et al.: Measurements of the relationship between CT hounsfield units and acoustic velocity and how it changes with photon energy and reconstruction method. IEEE Trans. Ultrason. Ferroelectr. Freq. Control 65(7), 1111\u20131124 (2018)","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"issue":"5","key":"3_CR21","doi-asserted-by":"publisher","first-page":"577","DOI":"10.1016\/j.media.2008.06.006","volume":"12","author":"W Wein","year":"2008","unstructured":"Wein, W., Brunke, S., Khamene, A., Callstrom, M.R., Navab, N.: Automatic CT-ultrasound registration for diagnostic imaging and image-guided intervention. Med. Image Anal. 12(5), 577\u2013585 (2008)","journal-title":"Med. Image Anal."},{"issue":"6","key":"3_CR22","doi-asserted-by":"publisher","first-page":"1707","DOI":"10.1109\/TMI.2023.3236216","volume":"42","author":"J Xu","year":"2023","unstructured":"Xu, J., et al.: NeSVoR: implicit neural representation for slice-to-volume reconstruction in MRI. IEEE Trans. Med. Imaging 42(6), 1707\u20131719 (2023)","journal-title":"IEEE Trans. Med. Imaging"},{"key":"3_CR23","doi-asserted-by":"crossref","unstructured":"Young, S.I., Balbastre, Y., Fischl, B., Golland, P., Iglesias, J.E.: Fully convolutional slice-to-volume reconstruction for single-stack MRI. In: Proceedings of the IEEE\/CVF Conference on Computer Vision and Pattern Recognition, pp. 11535\u201311545 (2024)","DOI":"10.1109\/CVPR52733.2024.01096"}],"container-title":["Lecture Notes in Computer Science","Simplifying Medical Ultrasound"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-032-06329-8_3","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,26]],"date-time":"2025-09-26T22:03:12Z","timestamp":1758924192000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/978-3-032-06329-8_3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,27]]},"ISBN":["9783032063281","9783032063298"],"references-count":23,"URL":"https:\/\/doi.org\/10.1007\/978-3-032-06329-8_3","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"value":"0302-9743","type":"print"},{"value":"1611-3349","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,27]]},"assertion":[{"value":"27 September 2025","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}},{"value":"This work was not supported by a specific grant and the authors have no competing interests to declare that are relevant to the content of this article.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Disclosure of Interests"}},{"value":"ASMUS","order":1,"name":"conference_acronym","label":"Conference Acronym","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"International Workshop on Advances in Simplifying Medical Ultrasound","order":2,"name":"conference_name","label":"Conference Name","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Daejeon","order":3,"name":"conference_city","label":"Conference City","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Korea (Republic of)","order":4,"name":"conference_country","label":"Conference Country","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2025","order":5,"name":"conference_year","label":"Conference Year","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"23 September 2025","order":7,"name":"conference_start_date","label":"Conference Start Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"23 September 2025","order":8,"name":"conference_end_date","label":"Conference End Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"6","order":9,"name":"conference_number","label":"Conference Number","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"asmus2025","order":10,"name":"conference_id","label":"Conference ID","group":{"name":"ConferenceInfo","label":"Conference Information"}}]}}