{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,22]],"date-time":"2026-05-22T18:05:23Z","timestamp":1779473123159,"version":"3.53.1"},"publisher-location":"Cham","reference-count":22,"publisher":"Springer Nature Switzerland","isbn-type":[{"value":"9783032066237","type":"print"},{"value":"9783032066244","type":"electronic"}],"license":[{"start":{"date-parts":[[2025,9,25]],"date-time":"2025-09-25T00:00:00Z","timestamp":1758758400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,9,25]],"date-time":"2025-09-25T00:00:00Z","timestamp":1758758400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026]]},"DOI":"10.1007\/978-3-032-06624-4_15","type":"book-chapter","created":{"date-parts":[[2025,9,26]],"date-time":"2025-09-26T07:43:56Z","timestamp":1758872636000},"page":"139-149","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Projection-Driven Robust Motion Compensation for\u00a0CBCT Using a\u00a0Patient-Specific Model Learned from\u00a0Prior Scans"],"prefix":"10.1007","author":[{"given":"Yilin","family":"Shao","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jingjing","family":"Dai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lei","family":"Deng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"XinKai","family":"Xu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jun","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yaoqin","family":"Xie","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaokun","family":"Liang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,9,25]]},"reference":[{"issue":"9","key":"15_CR1","doi-asserted-by":"publisher","first-page":"5044","DOI":"10.1118\/1.3480986","volume":"37","author":"F Bergner","year":"2010","unstructured":"Bergner, F., et al.: An investigation of 4D Cone-beam CT algorithms for slowly rotating scanners. Med. Phys. 37(9), 5044\u20135053 (2010)","journal-title":"Med. Phys."},{"issue":"12","key":"15_CR2","doi-asserted-by":"publisher","first-page":"6950","DOI":"10.21037\/jtd.2018.11.21","volume":"10","author":"RF Casal","year":"2018","unstructured":"Casal, R.F., et al.: Cone beam computed tomography-guided thin\/ultrathin bronchoscopy for diagnosis of peripheral lung nodules: a prospective pilot study. J. Thorac. Dis. 10(12), 6950\u20136962 (2018)","journal-title":"J. Thorac. Dis."},{"issue":"8","key":"15_CR3","doi-asserted-by":"publisher","first-page":"1365","DOI":"10.1109\/TMI.2012.2231694","volume":"32","author":"M Chen","year":"2013","unstructured":"Chen, M., Cao, K., Zheng, Y., Siochi, R.A.C.: Motion-compensated mega-voltage cone beam CT using the deformation derived directly from 2D projection images. IEEE Trans. Med. Imaging 32(8), 1365\u20131375 (2013)","journal-title":"IEEE Trans. Med. Imaging"},{"issue":"1","key":"15_CR4","first-page":"230","volume":"103","author":"F Cheng","year":"2024","unstructured":"Cheng, F., Qiao, Z., Zhao, L., Pu, J.: Real-time 3D\u20133D image fusion of CTA\/CBCT roadmap fluoroscopy in the transcatheter mitral intervention. Catheter. Cardiovasc. Interv. 103(1), 230\u2013233 (2024)","journal-title":"Catheter. Cardiovasc. Interv."},{"key":"15_CR5","doi-asserted-by":"publisher","DOI":"10.1016\/j.media.2023.102998","volume":"91","author":"J Dai","year":"2024","unstructured":"Dai, J., et al.: Volumetric tumor tracking from a single cone-beam X-ray projection image enabled by deep learning. Med. Image Anal. 91, 102998 (2024)","journal-title":"Med. Image Anal."},{"issue":"4","key":"15_CR6","doi-asserted-by":"publisher","first-page":"29","DOI":"10.14338\/IJPT-D-20-00056.1","volume":"7","author":"M Ornelas","year":"2021","unstructured":"Ornelas, M., et al.: CBCT-based adaptive assessment workflow for intensity modulated proton therapy for head and neck cancer. Inter. J. Particle Therapy 7(4), 29\u201341 (2021)","journal-title":"Inter. J. Particle Therapy"},{"issue":"6","key":"15_CR7","doi-asserted-by":"publisher","first-page":"612","DOI":"10.1364\/JOSAA.1.000612","volume":"1","author":"LA Feldkamp","year":"1984","unstructured":"Feldkamp, L.A., Davis, L.C., Kress, J.W.: Practical cone-beam algorithm. J. Opt. Soc. Am. A 1(6), 612\u2013619 (1984)","journal-title":"J. Opt. Soc. Am. A"},{"key":"15_CR8","doi-asserted-by":"crossref","unstructured":"Gardner, M., Dillon, O., Byrne, H., Keall, P., O\u2019Brien, R.: Data-driven rapid 4D cone-beam CT reconstruction for new generation Linacs. Phys. Med. Biol. 69(18), 18NT02 (2024)","DOI":"10.1088\/1361-6560\/ad780a"},{"key":"15_CR9","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1016\/j.phro.2018.02.004","volume":"5","author":"DC Hansen","year":"2018","unstructured":"Hansen, D.C., S\u00f8rensen, T.S.: Fast 4D cone-beam CT from 60 s acquisitions. Phys. Imaging Radiation Oncol. 5, 69\u201375 (2018)","journal-title":"Phys. Imaging Radiation Oncol."},{"issue":"3","key":"15_CR10","doi-asserted-by":"publisher","first-page":"1089","DOI":"10.1002\/mp.12102","volume":"44","author":"W Harris","year":"2017","unstructured":"Harris, W., Zhang, Y., Yin, F.F., Ren, L.: Estimating 4D-CBCT from prior information and extremely limited angle projections using structural PCA and weighted free-form deformation for lung radiotherapy. Med. Phys. 44(3), 1089\u20131104 (2017)","journal-title":"Med. Phys."},{"key":"15_CR11","doi-asserted-by":"crossref","unstructured":"Hindley, N., Shieh, C.C., Keall, P.: A patient-specific deep learning framework for 3D motion estimation and volumetric imaging during lung cancer radiotherapy. Phys. Med. Biol. 68(14), 14NT01 (2023)","DOI":"10.1088\/1361-6560\/ace1d0"},{"issue":"6","key":"15_CR12","doi-asserted-by":"publisher","first-page":"4158","DOI":"10.1002\/mp.17125","volume":"51","author":"H Huang","year":"2024","unstructured":"Huang, H., et al.: Deformable motion compensation in interventional cone-beam ct with a context-aware learned autofocus metric. Med. Phys. 51(6), 4158\u20134180 (2024)","journal-title":"Med. Phys."},{"issue":"21","key":"15_CR13","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ac309e","volume":"66","author":"C Jailin","year":"2021","unstructured":"Jailin, C., Roux, S., Sarrut, D., Rit, S.: Projection-based dynamic tomography. Phys. Med. Biol. 66(21), 215018 (2021)","journal-title":"Phys. Med. Biol."},{"issue":"8","key":"15_CR14","doi-asserted-by":"publisher","first-page":"1017","DOI":"10.1080\/0284186X.2018.1427885","volume":"57","author":"RE Kincaid","year":"2018","unstructured":"Kincaid, R.E., et al.: Evaluation of respiratory motion-corrected cone-beam CT at end expiration in abdominal radiotherapy sites: a prospective study. Acta Oncol. 57(8), 1017\u20131024 (2018)","journal-title":"Acta Oncol."},{"key":"15_CR15","doi-asserted-by":"publisher","DOI":"10.1016\/j.media.2024.103254","volume":"97","author":"A Lu","year":"2024","unstructured":"Lu, A., et al.: Vessel-targeted compensation of deformable motion in interventional cone-beam CT. Med. Image Anal. 97, 103254 (2024)","journal-title":"Med. Image Anal."},{"issue":"10","key":"15_CR16","doi-asserted-by":"publisher","first-page":"1513","DOI":"10.1109\/TMI.2008.2008962","volume":"28","author":"S Rit","year":"2009","unstructured":"Rit, S., Sarrut, D., Desbat, L.: Comparison of analytic and algebraic methods for motion-compensated cone-beam CT reconstruction of the thorax. IEEE Trans. Med. Imaging 28(10), 1513\u20131525 (2009)","journal-title":"IEEE Trans. Med. Imaging"},{"issue":"6","key":"15_CR17","doi-asserted-by":"publisher","first-page":"2283","DOI":"10.1118\/1.3115691","volume":"36","author":"S Rit","year":"2009","unstructured":"Rit, S., Wolthaus, J.W.H., Herk, M., Sonke, J.J.: On-the-fly motion-compensated cone-beam CT using an a priori model of the respiratory motion. Med. Phys. 36(6), 2283\u20132296 (2009)","journal-title":"Med. Phys."},{"key":"15_CR18","doi-asserted-by":"publisher","first-page":"181","DOI":"10.12659\/PJR.890745","volume":"79","author":"K Srinivasan","year":"2014","unstructured":"Srinivasan, K., Mohammadi, M., Shepherd, J.: Applications of linac-mounted kilovoltage cone-beam computed tomography in modern radiation therapy: a review. Pol. J. Radiol. 79, 181\u2013193 (2014)","journal-title":"Pol. J. Radiol."},{"issue":"10","key":"15_CR19","doi-asserted-by":"publisher","first-page":"e988","DOI":"10.1002\/mp.14312","volume":"47","author":"I Vergalasova","year":"2020","unstructured":"Vergalasova, I., Cai, J.: A modern review of the uncertainties in volumetric imaging of respiratory-induced target motion in lung radiotherapy. Med. Phys. 47(10), e988\u2013e1008 (2020)","journal-title":"Med. Phys."},{"issue":"8","key":"15_CR20","doi-asserted-by":"publisher","first-page":"5164","DOI":"10.1002\/mp.17269","volume":"51","author":"Y Zhang","year":"2024","unstructured":"Zhang, Y., Jiang, Z., Zhang, Y., Ren, L.: A review on 4D cone-beam CT (4D-CBCT) in radiation therapy: technical advances and clinical applications. Med. Phys. 51(8), 5164\u20135180 (2024)","journal-title":"Med. Phys."},{"issue":"12","key":"15_CR21","doi-asserted-by":"publisher","DOI":"10.1118\/1.4825097","volume":"40","author":"Y Zhang","year":"2013","unstructured":"Zhang, Y., Yin, F.F., Segars, W.P., Ren, L.: A technique for estimating 4D-CBCT using prior knowledge and limited-angle projections. Med. Phys. 40(12), 121701 (2013)","journal-title":"Med. Phys."},{"issue":"2","key":"15_CR22","doi-asserted-by":"publisher","first-page":"808","DOI":"10.1002\/mp.16103","volume":"50","author":"Z Zhang","year":"2023","unstructured":"Zhang, Z., Liu, J., Yang, D., Kamilov, U.S., Hugo, G.D.: Deep learning-based motion compensation for four-dimensional cone-beam computed tomography (4D-CBCT) reconstruction. Med. Phys. 50(2), 808\u2013820 (2023)","journal-title":"Med. Phys."}],"container-title":["Lecture Notes in Computer Science","Computational Mathematics Modeling in Cancer Analysis"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-032-06624-4_15","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,22]],"date-time":"2026-05-22T17:23:24Z","timestamp":1779470604000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/978-3-032-06624-4_15"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,25]]},"ISBN":["9783032066237","9783032066244"],"references-count":22,"URL":"https:\/\/doi.org\/10.1007\/978-3-032-06624-4_15","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"value":"0302-9743","type":"print"},{"value":"1611-3349","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,25]]},"assertion":[{"value":"25 September 2025","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}},{"value":"The authors have no competing interests to declare that are relevant to the content of this article.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Disclosure of Interests"}},{"value":"CMMCA","order":1,"name":"conference_acronym","label":"Conference Acronym","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"International Workshop on Computational Mathematics Modeling in Cancer Analysis","order":2,"name":"conference_name","label":"Conference Name","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Daejeon","order":3,"name":"conference_city","label":"Conference City","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Korea (Republic of)","order":4,"name":"conference_country","label":"Conference Country","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2025","order":5,"name":"conference_year","label":"Conference Year","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"27 September 2025","order":7,"name":"conference_start_date","label":"Conference Start Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"27 September 2025","order":8,"name":"conference_end_date","label":"Conference End Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"4","order":9,"name":"conference_number","label":"Conference Number","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"cmmca2025","order":10,"name":"conference_id","label":"Conference ID","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"https:\/\/miccai-workshop.github.io\/CMMCA2025\/index.html","order":11,"name":"conference_url","label":"Conference URL","group":{"name":"ConferenceInfo","label":"Conference Information"}}]}}