{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T00:06:10Z","timestamp":1740096370537,"version":"3.37.3"},"publisher-location":"Cham","reference-count":17,"publisher":"Springer International Publishing","isbn-type":[{"type":"print","value":"9783319034126"},{"type":"electronic","value":"9783319034133"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2014]]},"DOI":"10.1007\/978-3-319-03413-3_16","type":"book-chapter","created":{"date-parts":[[2013,11,12]],"date-time":"2013-11-12T13:27:49Z","timestamp":1384262869000},"page":"219-233","source":"Crossref","is-referenced-by-count":0,"title":["Development of a Lower-Limb Active Orthosis and a Walker for Gait Assistance"],"prefix":"10.1007","author":[{"given":"D.","family":"Sanz-Merodio","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.","family":"Cestari","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J. C.","family":"Arevalo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"X.","family":"Carrillo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"E.","family":"Garcia","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"issue":"4","key":"16_CR1","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1177\/1545968307300697","volume":"21","author":"A. Mayr","year":"2007","unstructured":"Mayr, A., Kofler, M., Quirbach, E., Matzak, H., Frhlich, K., Saltuari, L.: Prospective, blinded, randomized crossover study of gait rehabilitation in stroke patients using the lokomat gait orthosis. Neurorehabilitation and Neural Repair\u00a021(4), 307\u2013314 (2007), http:\/\/nnr.sagepub.com\/content\/21\/4\/307.short","journal-title":"Neurorehabilitation and Neural Repair"},{"issue":"1","key":"16_CR2","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1109\/TNSRE.2008.2008278","volume":"17","author":"H. Vallery","year":"2009","unstructured":"Vallery, H., van Asseldonk, E.H.F., Buss, M., van der Kooij, H.: Reference trajectory generation for rehabilitation robots: complementary limb motion estimation. IEEE Transactions on Neural Systems and Rehabilitation Engineering\u00a017(1), 23\u201330 (2009), http:\/\/ieeexplore.ieee.org\/xpls\/abs_all.jsp?arnumber=4668434","journal-title":"IEEE Transactions on Neural Systems and Rehabilitation Engineering"},{"issue":"2","key":"16_CR3","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1310\/6GL4-UM7X-519H-9JYD","volume":"11","author":"D.P.F. PhD","year":"2005","unstructured":"PhD, D.P.F., Msme, G.S.S., Mpt, A.R.D.: Powered lower limb orthoses for gait rehabilitation. Topics in Spinal Cord Injury Rehabilitation\u00a011(2), 34\u201349 (2005), http:\/\/dx.doi.org\/10.1310\/6GL4-UM7X-519H-9JYD","journal-title":"Topics in Spinal Cord Injury Rehabilitation"},{"key":"16_CR4","doi-asserted-by":"publisher","first-page":"314","DOI":"10.1515\/BMT.2006.063","volume":"51","author":"C. Fleischer","year":"2006","unstructured":"Fleischer, C.: Application of EMG signals for controlling exoskeleton robots. Biomed Tech\u00a051, 314\u2013319 (2006)","journal-title":"Biomed Tech"},{"issue":"12","key":"16_CR5","doi-asserted-by":"crossref","first-page":"1441","DOI":"10.1163\/156855307781746061","volume":"21","author":"K. Suzuki","year":"2007","unstructured":"Suzuki, K., Mito, G., Kawamoto, H., Hasegawa, Y., Sankai, Y.: Intention-based walking support for paraplegia patients with robot suit HAL. Advanced Robotics\u00a021(12), 1441\u20131469 (2007), http:\/\/www.tandfonline.com\/doi\/abs\/10.1163\/156855307781746061","journal-title":"Advanced Robotics"},{"key":"16_CR6","unstructured":"Lee, S., Sankai, Y.: Power assist control for walking aid with HAL-3 based on EMG and impedance adjustment around knee joint. In: Intl. Conference on Intelligent Robots and Systems (2002)"},{"key":"16_CR7","unstructured":"Visser, L.C., Carloni, R., Stramigioli, S.: Variable stiffness actuators: A port-based analysis and a comparison of energy efficiency. In: 2010 IEEE International Conference on Robotics and Automation (ICRA), pp. 3279\u20133284 (2010), http:\/\/ieeexplore.ieee.org\/xpls\/abs_all.jsp?arnumber=5509127"},{"key":"16_CR8","unstructured":"Craig, W.: Walker with lifting arms (August, 2005), http:\/\/global.soopat.com\/Patent\/Patent\/US7363931B2"},{"issue":"6","key":"16_CR9","doi-asserted-by":"publisher","first-page":"1240","DOI":"10.1109\/TRO.2006.884343","volume":"22","author":"E. Garcia","year":"2006","unstructured":"Garcia, E., Gonzalez de Santos, P.: On the improvement of walking performance in natural environments by a compliant adaptive gait. IEEE Transactions on Robotics\u00a022(6), 1240\u20131253 (2006)","journal-title":"IEEE Transactions on Robotics"},{"issue":"1","key":"16_CR10","doi-asserted-by":"publisher","first-page":"144","DOI":"10.1109\/TRO.2008.915453","volume":"24","author":"A.M. Dollar","year":"2008","unstructured":"Dollar, A.M., Herr, H.: Lower extremity exoskeletons and active orthoses: Challenges and state-of-the-art. IEEE Transactions on Robotics\u00a024(1), 144\u2013158 (2008)","journal-title":"IEEE Transactions on Robotics"},{"issue":"4","key":"16_CR11","doi-asserted-by":"publisher","first-page":"311","DOI":"10.1191\/0142331204tm124oa","volume":"26","author":"W. Jiang","year":"2004","unstructured":"Jiang, W., Liu, A., Howard, D.: Optimization of legged robot locomotion by control of foot-force distribution. Transactions of the Institute of Measurement and Control\u00a026(4), 311\u2013323 (2004)","journal-title":"Transactions of the Institute of Measurement and Control"},{"issue":"2","key":"16_CR12","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1310\/6GL4-UM7X-519H-9JYD","volume":"11","author":"D.P. Ferris","year":"2005","unstructured":"Ferris, D.P., Sawicki, G.S., Domingo, A.R.: Powered lower limb orthoses for gait rehabilitation. Topics in spinal cord injury rehabilitation\u00a011(2), 34 (2005), http:\/\/thomasland.metapress.com\/index\/6gl4um7x519h9jyd.pdf","journal-title":"Topics in spinal cord injury rehabilitation"},{"key":"16_CR13","first-page":"1","volume":"99","author":"J.W. Hurst","year":"2010","unstructured":"Hurst, J.W., Chestnutt, J.E., Rizzi, A.A.: The actuator with mechanically adjustable series compliance. IEEE Transactions on Robotics\u00a099, 1\u201310 (2010)","journal-title":"IEEE Transactions on Robotics"},{"issue":"10","key":"16_CR14","doi-asserted-by":"publisher","first-page":"761","DOI":"10.1016\/j.robot.2007.03.001","volume":"55","author":"R. Ham Van","year":"2007","unstructured":"Van Ham, R., Vanderborght, B., Van Damme, M., Verrelst, B., Lefeber, D.: MACCEPA, the mechanically adjustable compliance and controllable equilibrium position actuator: Design and implementation in a biped robot. Robotics and Autonomous Systems\u00a055(10), 761\u2013768 (2007)","journal-title":"Robotics and Autonomous Systems"},{"key":"16_CR15","doi-asserted-by":"crossref","unstructured":"Wolf, S., Hirzinger, G.: A new variable stiffness design: Matching requirements of the next robot generation. In: IEEE International Conference on Robotics and Automation, ICRA 2008, pp. 1741\u20131746 (2008)","DOI":"10.1109\/ROBOT.2008.4543452"},{"key":"16_CR16","doi-asserted-by":"crossref","unstructured":"Jafari, A., Tsagarakis, N.G., Vanderborght, B., Caldwell, D.G.: A novel actuator with adjustable stiffness (AwAS). In: 2010 IEEE\/RSJ International Conference on Intelligent Robots and Systems (IROS), pp. 4201\u20134206 (2010)","DOI":"10.1109\/IROS.2010.5648902"},{"key":"16_CR17","doi-asserted-by":"crossref","unstructured":"Sanz-Merodio, D., Cestari, M., Carlos, J., Garcia, E.: Control motion approach of a lower limb orthosis to reduce energy consumption. International Journal of Advanced Robotic Systems, 1 (2012), http:\/\/www.intechopen.com\/journals\/international_journal_of_advanced_robotic_systems\/control-motion-approach-of-a-lower-limb-orthosis-to-reduce-energy-consumption","DOI":"10.5772\/51903"}],"container-title":["Advances in Intelligent Systems and Computing","ROBOT2013: First Iberian Robotics Conference"],"original-title":[],"link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-319-03413-3_16","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,8,7]],"date-time":"2020-08-07T20:01:08Z","timestamp":1596830468000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-319-03413-3_16"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014]]},"ISBN":["9783319034126","9783319034133"],"references-count":17,"URL":"https:\/\/doi.org\/10.1007\/978-3-319-03413-3_16","relation":{},"ISSN":["2194-5357","2194-5365"],"issn-type":[{"type":"print","value":"2194-5357"},{"type":"electronic","value":"2194-5365"}],"subject":[],"published":{"date-parts":[[2014]]}}}