{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,9,8]],"date-time":"2024-09-08T10:25:57Z","timestamp":1725791157688},"publisher-location":"Cham","reference-count":16,"publisher":"Springer International Publishing","isbn-type":[{"type":"print","value":"9783319062686"},{"type":"electronic","value":"9783319062693"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2014]]},"DOI":"10.1007\/978-3-319-06269-3_8","type":"book-chapter","created":{"date-parts":[[2014,4,1]],"date-time":"2014-04-01T20:59:14Z","timestamp":1396385954000},"page":"63-71","source":"Crossref","is-referenced-by-count":4,"title":["Real-Time Estimation of Tibialis Anterior Muscle Thickness from Dysfunctional Lower Limbs Using Sonography"],"prefix":"10.1007","author":[{"given":"Xiaolong","family":"Li","sequence":"first","affiliation":[]},{"given":"Huihui","family":"Li","sequence":"additional","affiliation":[]},{"given":"Jizhou","family":"Li","sequence":"additional","affiliation":[]},{"given":"Yongjin","family":"Zhou","sequence":"additional","affiliation":[]},{"given":"Jianhao","family":"Tan","sequence":"additional","affiliation":[]}],"member":"297","reference":[{"issue":"6","key":"8_CR1","doi-asserted-by":"publisher","first-page":"682","DOI":"10.1002\/mus.10375","volume":"27","author":"P. Hodges","year":"2003","unstructured":"Hodges, P., Pengel, L., Herbert, R., Gandevia, S.: Measurement of muscle contraction with ultrasound imaging. Muscle & Nerve\u00a027(6), 682\u2013692 (2003)","journal-title":"Muscle & Nerve"},{"key":"8_CR2","doi-asserted-by":"crossref","unstructured":"Han, P., Chen, Y., Ao, L., Xie, G., Li, H., Wang, L., Zhou, Y.: Automatic thickness estimation for skeletal muscle in ultrasonography: evaluation of two enhancement methods. BioMedical Engineering OnLine\u00a012(6) (2013), doi:10.1186\/1475-925X-12-6","DOI":"10.1186\/1475-925X-12-6"},{"issue":"6","key":"8_CR3","doi-asserted-by":"publisher","first-page":"440","DOI":"10.1111\/j.1475-097X.2009.00897.x","volume":"29","author":"K. Thoirs","year":"2009","unstructured":"Thoirs, K., English, C.: Ultrasound measures of muscle thickness: intra-examiner reliability and influence of body position. Clinical Physiology and Functional Imaging\u00a029(6), 440\u2013446 (2009)","journal-title":"Clinical Physiology and Functional Imaging"},{"key":"8_CR4","doi-asserted-by":"crossref","unstructured":"Li, J., Zhou, Y.J., Zheng, Y.-P., Wang, L., Guo, J.-Y.: Sensitive and Efficient Detection of Quadriceps Muscle Thickness Changes in Cross-sectional Plane using Ultrasonography: A Feasibility Investigation. IEEE Journal of Biomedical and Health Informatics (2013), doi:10.1109\/JBHI.2013.2275002","DOI":"10.1109\/JBHI.2013.2275002"},{"issue":"4","key":"8_CR5","doi-asserted-by":"publisher","first-page":"665","DOI":"10.1016\/j.ultrasmedbio.2010.12.011","volume":"37","author":"Y. Zhou","year":"2011","unstructured":"Zhou, Y., Zheng, Y.-P.: Longitudinal enhancement of the hyperechoic regions in ultrasonography of muscles using a gabor filter bank approach: A preparation for semi-automatic muscle fiber orientation estimation. Ultrasound in Medicine & Biology\u00a037(4), 665\u2013673 (2011)","journal-title":"Ultrasound in Medicine & Biology"},{"issue":"4","key":"8_CR6","doi-asserted-by":"publisher","first-page":"1311","DOI":"10.1152\/japplphysiol.01229.2005","volume":"100","author":"I.D. Loram","year":"2006","unstructured":"Loram, I.D., Maganaris, C., Lakie, M.: Use of ultrasound to make noninvasive in vivo measurement of continuous changes in human muscle contractile length. Journal of Applied Physiology\u00a0100(4), 1311\u20131323 (2006)","journal-title":"Journal of Applied Physiology"},{"key":"8_CR7","doi-asserted-by":"publisher","first-page":"129","DOI":"10.1063\/1.1483902","volume":"92","author":"T. Muramatsu","year":"2002","unstructured":"Muramatsu, T., Muraoka, T., Kawakami, Y., Shibayama, A., Fukunaga, T.: In vivo determination of fascicle curvature in contracting human skeletal muscles. Journal of Applied Physiology\u00a092, 129\u2013134 (2002)","journal-title":"Journal of Applied Physiology"},{"issue":"9","key":"8_CR8","doi-asserted-by":"publisher","first-page":"1032","DOI":"10.1016\/j.medengphy.2010.07.004","volume":"32","author":"J. Guo","year":"2010","unstructured":"Guo, J., Zheng, Y.-P., Xie, H., Chen, X.: Continuous monitoring of electromyography (EMG), mechanomyography (MMG), sonomyography (SMG) and torque output during ramp and step isometric contractions. Medical Engineering & Physics\u00a032(9), 1032\u20131042 (2010)","journal-title":"Medical Engineering & Physics"},{"key":"8_CR9","doi-asserted-by":"publisher","first-page":"362","DOI":"10.1016\/0734-189X(87)90043-0","volume":"37","author":"M. Kass","year":"1987","unstructured":"Kass, M., Witkin, A.: Analyzing oriented patterns. Comput. Vis. Graph, Image Process\u00a037, 362\u2013397 (1987)","journal-title":"Comput. Vis. Graph, Image Process"},{"key":"8_CR10","doi-asserted-by":"crossref","unstructured":"Li, J., Zhou, Y.J., Ivanov, K., Zheng, Y.-P.: Estimation and visualization of longitudinal muscle motion using ultrasonography: A feasibility study. Ultrasonics\u00a054(3) (2014), doi:10.1016\/j.ultras.2013.09.024","DOI":"10.1016\/j.ultras.2013.09.024"},{"issue":"7","key":"8_CR11","doi-asserted-by":"publisher","first-page":"2603","DOI":"10.1007\/s00421-011-2227-2","volume":"112","author":"X. Chen","year":"2012","unstructured":"Chen, X., Zheng, Y.-P., Guo, J.-Y., Zhu, Z., Chan, S.-C., Zhang, Z.: Sonomyographic responses during voluntary isometric ramp contraction of the human rectus femoris muscle. European Journal of Applied Physiology\u00a0112(7), 2603\u20132614 (2012)","journal-title":"European Journal of Applied Physiology"},{"key":"8_CR12","doi-asserted-by":"publisher","first-page":"379","DOI":"10.1111\/j.1748-1716.1993.tb09573.x","volume":"148","author":"H.E. Berg","year":"1993","unstructured":"Berg, H.E., Tedner, B., Tesch, P.A.: Changes in lower limb muscle crosssectional area and tissue fluid volume after transition from standing to supine. Acta Physiol. Scand.\u00a0148, 379\u2013385 (1993)","journal-title":"Acta Physiol. Scand."},{"key":"8_CR13","doi-asserted-by":"publisher","first-page":"405","DOI":"10.1016\/j.medengphy.2005.07.012","volume":"28","author":"Y.-P. Zheng","year":"2006","unstructured":"Zheng, Y.-P., Chan, M., Shi, J., Chen, X., Huang, Q.H.: Sonomyography: Monitoring morphological changes of forearm muscles in actions with the feasibility for the control of powered prosthesis. Med. Eng. Phys.\u00a028, 405\u2013415 (2006)","journal-title":"Med. Eng. Phys."},{"issue":"6","key":"8_CR14","doi-asserted-by":"publisher","first-page":"894","DOI":"10.1016\/j.ultrasmedbio.2008.11.017","volume":"35","author":"J. Guo","year":"2009","unstructured":"Guo, J., Zheng, Y.-P., Huang, Q., Chen, X., He, J., Lai-Wa Chan, H.: Performances of one-dimensional sonomyography and surface electromyography in tracking guided patterns of wrist extension. Ultrasound in Medicine & Biology\u00a035(6), 894\u2013902 (2009)","journal-title":"Ultrasound in Medicine & Biology"},{"issue":"7","key":"8_CR15","doi-asserted-by":"publisher","first-page":"1076","DOI":"10.1016\/j.ultrasmedbio.2010.04.015","volume":"36","author":"X. Chen","year":"2010","unstructured":"Chen, X., Zheng, Y.-P., Guo, J.-Y., Shi, J.: Sonomyography (SMG) control for powered prosthetic hand: A study with normal subjects. Ultrasound in Medicine & Biology\u00a036(7), 1076\u20131088 (2010)","journal-title":"Ultrasound in Medicine & Biology"},{"key":"8_CR16","series-title":"Lecture Notes in Computer Science","doi-asserted-by":"publisher","first-page":"864","DOI":"10.1007\/978-3-642-33712-3_62","volume-title":"Computer Vision \u2013 ECCV 2012","author":"K. Zhang","year":"2012","unstructured":"Zhang, K., Zhang, L., Yang, M.-H.: Real-time compressive tracking. In: Fitzgibbon, A., Lazebnik, S., Perona, P., Sato, Y., Schmid, C. (eds.) ECCV 2012, Part III. LNCS, vol.\u00a07574, pp. 864\u2013877. Springer, Heidelberg (2012)"}],"container-title":["Lecture Notes in Computer Science","Health Information Science"],"original-title":[],"link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-319-06269-3_8","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,26]],"date-time":"2019-05-26T10:07:48Z","timestamp":1558865268000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-319-06269-3_8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014]]},"ISBN":["9783319062686","9783319062693"],"references-count":16,"URL":"https:\/\/doi.org\/10.1007\/978-3-319-06269-3_8","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"type":"print","value":"0302-9743"},{"type":"electronic","value":"1611-3349"}],"subject":[],"published":{"date-parts":[[2014]]}}}