{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,9,8]],"date-time":"2024-09-08T11:47:18Z","timestamp":1725796038277},"publisher-location":"Cham","reference-count":17,"publisher":"Springer International Publishing","isbn-type":[{"type":"print","value":"9783319078861"},{"type":"electronic","value":"9783319078878"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2014]]},"DOI":"10.1007\/978-3-319-07887-8_24","type":"book-chapter","created":{"date-parts":[[2014,6,23]],"date-time":"2014-06-23T09:10:53Z","timestamp":1403514653000},"page":"166-173","source":"Crossref","is-referenced-by-count":0,"title":["Comparative Performance Evaluation of Contrast-Detail in Full Field Digital Mammography (FFDM) Systems Using Ideal (Hotelling) Observer versus Automated CDMAM Analysis"],"prefix":"10.1007","author":[{"given":"Ioannis","family":"Delakis","sequence":"first","affiliation":[]},{"given":"Robert","family":"Wise","sequence":"additional","affiliation":[]},{"given":"Lauren","family":"Morris","sequence":"additional","affiliation":[]},{"given":"Eugenia","family":"Kulama","sequence":"additional","affiliation":[]}],"member":"297","reference":[{"key":"24_CR1","volume-title":"The European protocol for the quality control of the physical and technical aspects of mammography screening","author":"R. Engen Van","year":"2006","unstructured":"Van Engen, R., Young, K., Bosmans, H., Thijssen, H.: The European protocol for the quality control of the physical and technical aspects of mammography screening. Euref, Luxembourg (2006)"},{"key":"24_CR2","unstructured":"Young, K., Johnson, B., Bosmans, H., Van Engen, R.: Development of minimum standards for image quality and dose in digital mammography. In: Digital Mammography IWDM 2004, Durham NC, USA (2005)"},{"key":"24_CR3","doi-asserted-by":"crossref","unstructured":"Young, K., Alsager, A., Oduko, J., Bosmans, H., Verbrugge, B., Geerste, T., et al.: Evaluation of software for reading images of the CDMAM test object to assess digital mammography systems. In: Proc. SPIE, vol. 6913, p. 69131C (2008)","DOI":"10.1117\/12.770571"},{"key":"24_CR4","doi-asserted-by":"crossref","unstructured":"Young, K.C., Cook, J.J.H., Oduko, J.M., Bosmans, H.: Comparison of software and human observers in reading images of the CDMAM test object to assess digital mammography systems. In: Proc. SPIE, vol. 6142, p. 614206 (2006)","DOI":"10.1117\/12.653296"},{"key":"24_CR5","doi-asserted-by":"crossref","unstructured":"Sandrik, J., Wagner, R.: Absolute measures of physical image quality: measurement and application to radiographic magnification 9(4), 540-9 (1982)","DOI":"10.1118\/1.595099"},{"issue":"21","key":"24_CR6","doi-asserted-by":"publisher","first-page":"9758","DOI":"10.1073\/pnas.90.21.9758","volume":"90","author":"H. Barrett","year":"1993","unstructured":"Barrett, H., Yao, J., Rolland, J., Myers, K.: Model observers for assessment of image quality. Proc. Natl. Acad. Sci.\u00a090(21), 9758\u20139765 (1993)","journal-title":"Proc. Natl. Acad. Sci."},{"key":"24_CR7","unstructured":"Kyprianou, I.S.: A method for total x-ray imaging system evaluation. PhD Thesis. University of New York, Buffalo, NY (2004)"},{"issue":"2","key":"24_CR8","doi-asserted-by":"publisher","first-page":"613","DOI":"10.1118\/1.1844151","volume":"32","author":"I.S. Kyprianou","year":"2005","unstructured":"Kyprianou, I.S., Rudin, S., Bednarek, D., Hoffman, K.: Generalizing the MTF and DQE to include x-ray scatter and focal spot unsharpness: application to a new microangiographic system. Med. Phys.\u00a032(2), 613\u2013626 (2005)","journal-title":"Med. Phys."},{"key":"24_CR9","doi-asserted-by":"crossref","unstructured":"Kyprianou, I., Ganguly, A., Rudin, S., Bednarek, D., Gallas, B., Myers, K.: Efficiency of the Human Observer Compared to an Ideal Observer Based on a Generalized NEQ Which Incorporates Scatter and Geometric Unsharpness: Evaluation with a 2AFC Experiment. In: Proc. Soc. Photo. Opt. Instrum. Eng., vol. 5749, pp. 251\u2013262 (2005)","DOI":"10.1117\/12.595870"},{"key":"24_CR10","doi-asserted-by":"crossref","unstructured":"Liu, H., Kyprianou, I.S., Badano, A., Myers, K.J., Jennings, R.J., Park, S., et al.: SKE\/BKE Task-based methodology for calculating Hotelling observer SNR in mammography. In: Proc. of the SPIE, Medical Imaging, vol. 7258 (2009)","DOI":"10.1117\/12.813833"},{"key":"24_CR11","doi-asserted-by":"crossref","unstructured":"Liu, H., Badano, A., Chakrabarti, K., Kaczmarek, R., Kyprianou, I.: Task specific evaluation of clinical full field digital mammography systems using the Fourier definition of the Hotelling observer SNR. In: Proc. of the SPIE, Medical Imaging, vol. 7622 (2010)","DOI":"10.1117\/12.845509"},{"key":"24_CR12","unstructured":"Liu, H.: Task specific evaluation methodology for clinical Full Field Digital Mammography. PhD Thesis. University of Maryland, College Park (2012)"},{"key":"24_CR13","unstructured":"Commissioning and routine testing of Full Field Digital Mammography Systems. NHSBSP Equipment Report 0604. NHS Cancer Screening Programmes, Sheffield. Report No.: version 4 (in press)"},{"key":"24_CR14","doi-asserted-by":"crossref","unstructured":"Marshall, N.: A comparison between objective and subjective image quality measurements for a full field digital mammography system 51(10), 2441\u201363 (2006)","DOI":"10.1088\/0031-9155\/51\/10\/006"},{"key":"24_CR15","doi-asserted-by":"publisher","first-page":"489","DOI":"10.1088\/0031-9155\/30\/6\/001","volume":"30","author":"R.F. Wagner","year":"1985","unstructured":"Wagner, R.F., Brown, D.: Unified SNR analysis of medical imaging systems. Phys. Med. Biol.\u00a030, 489\u2013518 (1985)","journal-title":"Phys. Med. Biol."},{"issue":"5","key":"24_CR16","doi-asserted-by":"publisher","first-page":"643","DOI":"10.1118\/1.597576","volume":"22","author":"A. Burgess","year":"1995","unstructured":"Burgess, A.: Comparison of receiver operating characteristic and forced choice observer performance measurement methods. Medical Physics\u00a022(5), 643 (1995)","journal-title":"Medical Physics"},{"key":"24_CR17","unstructured":"Review of measurements on full field digital mammography systems. NHSBSP Equipment Report 0901. NHS Cancer Screening Programme (2009)"}],"container-title":["Lecture Notes in Computer Science","Breast Imaging"],"original-title":[],"link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-319-07887-8_24","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,26]],"date-time":"2019-05-26T23:45:54Z","timestamp":1558914354000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-319-07887-8_24"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014]]},"ISBN":["9783319078861","9783319078878"],"references-count":17,"URL":"https:\/\/doi.org\/10.1007\/978-3-319-07887-8_24","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"type":"print","value":"0302-9743"},{"type":"electronic","value":"1611-3349"}],"subject":[],"published":{"date-parts":[[2014]]}}}