{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,3,27]],"date-time":"2025-03-27T03:48:15Z","timestamp":1743047295907,"version":"3.40.3"},"publisher-location":"Cham","reference-count":13,"publisher":"Springer International Publishing","isbn-type":[{"type":"print","value":"9783319104034"},{"type":"electronic","value":"9783319104041"}],"license":[{"start":{"date-parts":[[2014,1,1]],"date-time":"2014-01-01T00:00:00Z","timestamp":1388534400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2014]]},"DOI":"10.1007\/978-3-319-10404-1_15","type":"book-chapter","created":{"date-parts":[[2014,8,31]],"date-time":"2014-08-31T12:21:17Z","timestamp":1409487677000},"page":"114-121","source":"Crossref","is-referenced-by-count":5,"title":["Joint Parametric Reconstruction and Motion Correction Framework for Dynamic PET Data"],"prefix":"10.1007","author":[{"given":"Jieqing","family":"Jiao","sequence":"first","affiliation":[]},{"given":"Alexandre","family":"Bousse","sequence":"additional","affiliation":[]},{"given":"Kris","family":"Thielemans","sequence":"additional","affiliation":[]},{"given":"Pawel","family":"Markiewicz","sequence":"additional","affiliation":[]},{"given":"Ninon","family":"Burgos","sequence":"additional","affiliation":[]},{"given":"David","family":"Atkinson","sequence":"additional","affiliation":[]},{"given":"Simon","family":"Arridge","sequence":"additional","affiliation":[]},{"given":"Brian F.","family":"Hutton","sequence":"additional","affiliation":[]},{"given":"S\u00e9bastien","family":"Ourselin","sequence":"additional","affiliation":[]}],"member":"297","reference":[{"issue":"10","key":"15_CR1","doi-asserted-by":"publisher","first-page":"1977","DOI":"10.1109\/TMI.2012.2212203","volume":"31","author":"G. Wang","year":"2012","unstructured":"Wang, G., Qi, J.: An optimization transfer algorithm for nonlinear parametric image reconstruction from dynamic PET data. IEEE. Trans. on Med. Imag.\u00a031(10), 1977\u20131988 (2012)","journal-title":"IEEE. Trans. on Med. Imag."},{"key":"15_CR2","series-title":"Lecture Notes in Computer Science","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1007\/978-3-642-40760-4_20","volume-title":"Medical Image Computing and Computer-Assisted Intervention \u2013 MICCAI 2013","author":"X. Cheng","year":"2013","unstructured":"Cheng, X., Navab, N., Ziegler, S.I., Shi, K.: Direct Parametric Image Reconstruction of Rapid Multi-tracer PET. In: Mori, K., Sakuma, I., Sato, Y., Barillot, C., Navab, N. (eds.) MICCAI 2013, Part III. LNCS, vol.\u00a08151, pp. 155\u2013162. Springer, Heidelberg (2013)"},{"key":"15_CR3","series-title":"Lecture Notes in Computer Science","doi-asserted-by":"publisher","first-page":"581","DOI":"10.1007\/978-3-642-23623-5_73","volume-title":"Medical Image Computing and Computer-Assisted Intervention \u2013 MICCAI 2011","author":"S. Pedemonte","year":"2011","unstructured":"Pedemonte, S., Bousse, A., Hutton, B.F., Arridge, S., Ourselin, S.: 4-D generative model for PET\/MRI reconstruction. In: Fichtinger, G., Martel, A., Peters, T. (eds.) MICCAI 2011, Part I. LNCS, vol.\u00a06891, pp. 581\u2013588. Springer, Heidelberg (2011)"},{"key":"15_CR4","doi-asserted-by":"publisher","first-page":"225","DOI":"10.1016\/j.neuroimage.2013.08.031","volume":"84","author":"J. Jiao","year":"2014","unstructured":"Jiao, J., Searle, G.E., Tziortzi, A.C., Salinas, C.A., Gunn, R.N., Schnabel, J.A.: Spatio-temporal pharmacokinetic model based registration of 4D PET neuroimaging data. Neuroimage\u00a084, 225\u2013235 (2014)","journal-title":"Neuroimage"},{"key":"15_CR5","unstructured":"Madsen, K., Nielsen, H.B., Tingleff, O.: Methods for non-linear least-squares problems. Technical report, Technical University of Denmark (2004)"},{"issue":"1","key":"15_CR6","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1109\/42.370409","volume":"14","author":"A.R. Pierro De","year":"1995","unstructured":"De Pierro, A.R.: A modified expectation maximization algorithm for penalized likelihood estimation in emission tomography. IEEE Trans. on Med. Imag.\u00a014(1), 132\u2013137 (1995)","journal-title":"IEEE Trans. on Med. Imag."},{"key":"15_CR7","doi-asserted-by":"publisher","first-page":"1505","DOI":"10.1088\/0031-9155\/55\/5\/016","volume":"55","author":"G. Wang","year":"2010","unstructured":"Wang, G., Qi, J.: Acceleration of the direct reconstruction of linear parametric images using nested algorithms. Phys. Med. Biol.\u00a055, 1505\u20131517 (2010)","journal-title":"Phys. Med. Biol."},{"issue":"1","key":"15_CR8","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1038\/jcbfm.1993.5","volume":"13","author":"V.J. Cunningham","year":"1993","unstructured":"Cunningham, V.J., Jones, T.: Spectral analysis of dynamic PET studies. J. Cereb. Blood Flow Metab.\u00a013(1), 15\u201323 (1993)","journal-title":"J. Cereb. Blood Flow Metab."},{"key":"15_CR9","unstructured":"Thielemans, K., Schleyer, P., Dunn, J., Marsden, P.K., Manjeshwar, R.M.: Using PCA to detect head motion from PET list mode data. In: IEEE Nucl. Sci. Syp. & Med. Im. Conf. (2013)"},{"key":"15_CR10","series-title":"Lecture Notes in Computer Science","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1007\/978-3-642-40811-3_19","volume-title":"Medical Image Computing and Computer-Assisted Intervention \u2013 MICCAI 2013","author":"N. Burgos","year":"2013","unstructured":"Burgos, N., Cardoso, M.J., Modat, M., Pedemonte, S., Dickson, J., Barnes, A., Duncan, J.S., Atkinson, D., Arridge, S.R., Hutton, B.F., Ourselin, S.: Attenuation correction synthesis for hybrid PET-MR scanners. In: Mori, K., Sakuma, I., Sato, Y., Barillot, C., Navab, N. (eds.) MICCAI 2013, Part I. LNCS, vol.\u00a08149, pp. 147\u2013154. Springer, Heidelberg (2013)"},{"issue":"5","key":"15_CR11","doi-asserted-by":"publisher","first-page":"694","DOI":"10.1109\/42.736021","volume":"17","author":"J. Fitzpatrick","year":"1998","unstructured":"Fitzpatrick, J., West, J., Maurer Jr., C.R.: Predicting error in rigid-body point-based registration. IEEE Trans. on Med. Imag.\u00a017(5), 694\u2013702 (1998)","journal-title":"IEEE Trans. on Med. Imag."},{"issue":"6","key":"15_CR12","doi-asserted-by":"publisher","first-page":"635","DOI":"10.1097\/00004647-200106000-00002","volume":"21","author":"R.N. Gunn","year":"2001","unstructured":"Gunn, R.N., Gunn, S.R., Cunningham, V.J.: Positron emission tomography compartmental models. J. Cereb. Blood Flow Metab.\u00a021(6), 635\u2013652 (2001)","journal-title":"J. Cereb. Blood Flow Metab."},{"issue":"4","key":"15_CR13","doi-asserted-by":"publisher","first-page":"867","DOI":"10.1088\/0031-9155\/57\/4\/867","volume":"57","author":"K. Thielemans","year":"2012","unstructured":"Thielemans, K., Tsoumpas, C., Mustafovic, S., Beisel, T., Aguiar, P., Dikaios, N., Jacobson, M.W.: STIR: software for tomographic image reconstruction release 2. Phys. Med. Biol.\u00a057(4), 867\u2013883 (2012)","journal-title":"Phys. Med. Biol."}],"container-title":["Lecture Notes in Computer Science","Medical Image Computing and Computer-Assisted Intervention \u2013 MICCAI 2014"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-319-10404-1_15","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,9,13]],"date-time":"2019-09-13T20:08:49Z","timestamp":1568405329000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-319-10404-1_15"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014]]},"ISBN":["9783319104034","9783319104041"],"references-count":13,"URL":"https:\/\/doi.org\/10.1007\/978-3-319-10404-1_15","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"type":"print","value":"0302-9743"},{"type":"electronic","value":"1611-3349"}],"subject":[],"published":{"date-parts":[[2014]]}}}