{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,3,26]],"date-time":"2025-03-26T03:01:56Z","timestamp":1742958116798,"version":"3.40.3"},"publisher-location":"Cham","reference-count":16,"publisher":"Springer International Publishing","isbn-type":[{"type":"print","value":"9783319104034"},{"type":"electronic","value":"9783319104041"}],"license":[{"start":{"date-parts":[[2014,1,1]],"date-time":"2014-01-01T00:00:00Z","timestamp":1388534400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2014]]},"DOI":"10.1007\/978-3-319-10404-1_70","type":"book-chapter","created":{"date-parts":[[2014,8,31]],"date-time":"2014-08-31T12:21:17Z","timestamp":1409487677000},"page":"561-568","source":"Crossref","is-referenced-by-count":8,"title":["Multi-parametric 3D Quantitative Ultrasound Vibro-Elastography Imaging for Detecting Palpable Prostate Tumors"],"prefix":"10.1007","author":[{"given":"Omid","family":"Mohareri","sequence":"first","affiliation":[]},{"given":"Angelica","family":"Ruszkowski","sequence":"additional","affiliation":[]},{"given":"Julio","family":"Lobo","sequence":"additional","affiliation":[]},{"given":"Joseph","family":"Ischia","sequence":"additional","affiliation":[]},{"given":"Ali","family":"Baghani","sequence":"additional","affiliation":[]},{"given":"Guy","family":"Nir","sequence":"additional","affiliation":[]},{"given":"Hani","family":"Eskandari","sequence":"additional","affiliation":[]},{"given":"Edward","family":"Jones","sequence":"additional","affiliation":[]},{"given":"Ladan","family":"Fazli","sequence":"additional","affiliation":[]},{"given":"Larry","family":"Goldenberg","sequence":"additional","affiliation":[]},{"given":"Mehdi","family":"Moradi","sequence":"additional","affiliation":[]},{"given":"Septimiu","family":"Salcudean","sequence":"additional","affiliation":[]}],"member":"297","reference":[{"key":"70_CR1","doi-asserted-by":"crossref","unstructured":"Salcudean, S.E., Sahebjavaher, R.S., et al.: Biomechanical modeling of the prostate for procedure guidance and simulation. In: Soft Tissue Biomechanical Modeling for Computer Assisted Surgery, vol.\u00a011, pp. 169\u2013198. Springer (2012)","DOI":"10.1007\/8415_2012_121"},{"issue":"6","key":"70_CR2","doi-asserted-by":"publisher","first-page":"2039","DOI":"10.1016\/j.juro.2012.01.063","volume":"187","author":"M. Brock","year":"2012","unstructured":"Brock, M., Von Bodman, C., et al.: The impact of real-time elastography guiding a systematic prostate biopsy to improve cancer detection rate: A prospective study of 353 patients. J. Urol.\u00a0187(6), 2039\u20132043 (2012)","journal-title":"J. Urol."},{"issue":"7","key":"70_CR3","doi-asserted-by":"publisher","first-page":"1033","DOI":"10.1016\/j.ultrasmedbio.2007.11.024","volume":"34","author":"M. Zhang","year":"2008","unstructured":"Zhang, M., Nigwekar, P., et al.: Quantitative characterization of viscoelastic properties of human prostate correlated with histology. Ultrasound Med. Biol.\u00a034(7), 1033\u20131042 (2008)","journal-title":"Ultrasound Med. Biol."},{"issue":"4","key":"70_CR4","doi-asserted-by":"publisher","first-page":"576","DOI":"10.1016\/j.ultrasmedbio.2009.12.006","volume":"36","author":"L. Zhai","year":"2010","unstructured":"Zhai, L., Madden, J., et al.: Acoustic radiation force impulse imaging of human prostates ex vivo. Ultrasound Med. Biol.\u00a036(4), 576\u2013588 (2010)","journal-title":"Ultrasound Med. Biol."},{"issue":"9","key":"70_CR5","doi-asserted-by":"publisher","first-page":"3280","DOI":"10.1007\/s00464-013-2906-7","volume":"27","author":"S. Ahmad","year":"2013","unstructured":"Ahmad, S., Cao, R., et al.: Transrectal quantitative shear wave elastography in the detection and characterisation of prostate cancer. Surg. Endosc.\u00a027(9), 3280\u20133287 (2013)","journal-title":"Surg. Endosc."},{"issue":"1","key":"70_CR6","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1016\/j.juro.2012.08.183","volume":"189","author":"M. Brock","year":"2013","unstructured":"Brock, M., Eggert, T., et al.: Multiparametric ultrasound of the prostate: adding contrast enhanced ultrasound to real-time elastography to detect histopathologically confirmed cancer. J. Urol.\u00a0189(1), 93\u201398 (2013)","journal-title":"J. Urol."},{"issue":"2","key":"70_CR7","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1016\/j.ultrasmedbio.2005.09.015","volume":"32","author":"E. Turgay","year":"2008","unstructured":"Turgay, E., Salcudean, S., et al.: Identifying mechanical properties of tissue by ultrasound. Ultrasound Med. Biol.\u00a032(2), 221\u2013235 (2008)","journal-title":"Ultrasound Med. Biol."},{"issue":"10","key":"70_CR8","doi-asserted-by":"publisher","first-page":"1990","DOI":"10.1109\/TBME.2006.881780","volume":"53","author":"R. Zahiri-Azar","year":"2000","unstructured":"Zahiri-Azar, R., Salcudean, S.E.: Motion estimation in ultrasound images using time domain cross correlation with prior estimates. IEEE Trans. Biomed. Eng.\u00a053(10), 1990\u2013(2000)","journal-title":"IEEE Trans. Biomed. Eng."},{"issue":"5232","key":"70_CR9","doi-asserted-by":"publisher","first-page":"1854","DOI":"10.1126\/science.7569924","volume":"269","author":"R. Muthupillai","year":"1995","unstructured":"Muthupillai, R., Lomas, D.J.: Magnetic resonance elastography by direct visualization of propagating acoustic strain waves. Science\u00a0269(5232), 1854\u20131857 (1995)","journal-title":"Science"},{"key":"70_CR10","series-title":"Lecture Notes in Computer Science","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1007\/978-3-642-21504-9_8","volume-title":"Information Processing in Computer-Assisted Interventions","author":"T. Adebar","year":"2011","unstructured":"Adebar, T., Salcudean, S., Mahdavi, S., Moradi, M., Nguan, C., Goldenberg, L.: A robotic system for intra-operative trans-rectal ultrasound and ultrasound elastography in radical prostatectomy. In: Taylor, R.H., Yang, G.-Z. (eds.) IPCAI 2011. LNCS, vol.\u00a06689, pp. 79\u201389. Springer, Heidelberg (2011)"},{"issue":"2","key":"70_CR11","doi-asserted-by":"publisher","first-page":"411","DOI":"10.1002\/mrm.24268","volume":"69","author":"R.S. Sahebjavaher","year":"2013","unstructured":"Sahebjavaher, R.S., Baghani, A., et al.: Transperineal prostate mr elastography: Initial in vivo results. Magn. Reson. Med.\u00a069(2), 411\u2013420 (2013)","journal-title":"Magn. Reson. Med."},{"issue":"7","key":"70_CR12","doi-asserted-by":"publisher","first-page":"1332","DOI":"10.1109\/TUFFC.2011.1953","volume":"58","author":"H. Eskandari","year":"2011","unstructured":"Eskandari, H., Goksel, O., et al.: Bandpass sampling of high-frequency tissue motion. IEEE Trans. Ultrason. Ferroelectr. Freq. Control.\u00a058(7), 1332\u20131343 (2011)","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control."},{"key":"70_CR13","doi-asserted-by":"crossref","unstructured":"Nir, G., Salcudean, S.E.: Registration of whole-mount histology and tomography of the prostate using particle filtering. In: Proc. SPIE, vol.\u00a08676, pp. 86760E\u201386760E\u20139 (2013)","DOI":"10.1117\/12.2007008"},{"issue":"1","key":"70_CR14","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1023\/A:1010933404324","volume":"45","author":"L. Breiman","year":"2001","unstructured":"Breiman, L.: Random forests. Mach. Learn.\u00a045(1), 5\u201332 (2001)","journal-title":"Mach. Learn."},{"issue":"12","key":"70_CR15","doi-asserted-by":"publisher","first-page":"897","DOI":"10.1097\/00000478-198812000-00001","volume":"12","author":"J.E. McNeal","year":"1988","unstructured":"McNeal, J.E., Redwine, A.E., et al.: Zonal distribution of prostatic adenocarcinoma. correlation with histologic pattern and direction of spread. Am. J. Surg. Pathol.\u00a012(12), 897\u2013906 (1988)","journal-title":"Am. J. Surg. Pathol."},{"issue":"6","key":"70_CR16","doi-asserted-by":"publisher","first-page":"1354","DOI":"10.1016\/j.eururo.2008.02.035","volume":"54","author":"G. Salomon","year":"2008","unstructured":"Salomon, G., Kollerman, J., et al.: Evaluation of prostate cancer detection with ultrasound real-time elastography: A comparison with step section pathological analysis after radical prostatectomy. Eur. Urol.\u00a054(6), 1354\u20131362 (2008)","journal-title":"Eur. Urol."}],"container-title":["Lecture Notes in Computer Science","Medical Image Computing and Computer-Assisted Intervention \u2013 MICCAI 2014"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-319-10404-1_70","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,9,13]],"date-time":"2019-09-13T20:05:44Z","timestamp":1568405144000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-319-10404-1_70"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014]]},"ISBN":["9783319104034","9783319104041"],"references-count":16,"URL":"https:\/\/doi.org\/10.1007\/978-3-319-10404-1_70","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"type":"print","value":"0302-9743"},{"type":"electronic","value":"1611-3349"}],"subject":[],"published":{"date-parts":[[2014]]}}}