{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T07:04:53Z","timestamp":1763017493548,"version":"3.40.3"},"publisher-location":"Cham","reference-count":47,"publisher":"Springer International Publishing","isbn-type":[{"type":"print","value":"9783319157856"},{"type":"electronic","value":"9783319157863"}],"license":[{"start":{"date-parts":[[2015,1,1]],"date-time":"2015-01-01T00:00:00Z","timestamp":1420070400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2015]]},"DOI":"10.1007\/978-3-319-15786-3_9","type":"book-chapter","created":{"date-parts":[[2015,2,13]],"date-time":"2015-02-13T10:45:27Z","timestamp":1423824327000},"page":"135-151","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":22,"title":["Review on Performance Metrics for Energy Efficiency in Data Center: The Role of Thermal Management"],"prefix":"10.1007","author":[{"given":"Alfonso","family":"Capozzoli","sequence":"first","affiliation":[]},{"given":"Marta","family":"Chinnici","sequence":"additional","affiliation":[]},{"given":"Marco","family":"Perino","sequence":"additional","affiliation":[]},{"given":"Gianluca","family":"Serale","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2015,2,14]]},"reference":[{"key":"9_CR1","unstructured":"ASHRAE: 2011 Thermal Guidelines for Data Processing Environments \u2013 Expanded Data Center Classes and Usage Guidance. Technical report, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc (2011)"},{"key":"9_CR2","unstructured":"The Green Grid: The Green Grid Energy Policy Research for Data Centres. Technical report, White Paper #25, The Green Grid (2009)"},{"key":"9_CR3","unstructured":"Tozer, R., Flucker, S., Romano, A.: Scalable data centre efficiency. In: CIBSE Technical Symposium, Liverpool John Moores University, Liverpool, UK, 11\u201312 April 2013"},{"issue":"1","key":"9_CR4","doi-asserted-by":"publisher","first-page":"1","DOI":"10.2200\/S00193ED1V01Y200905CAC006","volume":"4","author":"LA Barroso","year":"2009","unstructured":"Barroso, L.A., H\u00f6lzle, U.: The datacenter as a computer: an introduction to the design of warehouse-scale machines. Synth. Lect. Comput. Archit. 4(1), 1\u2013108 (2009)","journal-title":"Synth. Lect. Comput. Archit."},{"issue":"3","key":"9_CR5","doi-asserted-by":"publisher","first-page":"034008","DOI":"10.1088\/1748-9326\/3\/3\/034008","volume":"3","author":"JG Koomey","year":"2008","unstructured":"Koomey, J.G.: Worldwide electricity used in data centers. Environ. Res. Lett. 3(3), 034008 (2008)","journal-title":"Environ. Res. Lett."},{"key":"9_CR6","unstructured":"Schaeppi, B., Bogner, T., Schloesser, A., Stobbe, L., De Asuncao, M.D.: Metrics for energy efficiency assessment in data centers and server rooms. In: Electronics Goes Green 2012+ (EGG), pp. 1\u20136. IEEE (2012)"},{"key":"9_CR7","unstructured":"The uptime institute: heat density trends in data processing, computer systems and telecommunication equipment. Technical report, The Uptime Institute (2000)"},{"issue":"3","key":"9_CR8","doi-asserted-by":"publisher","first-page":"639","DOI":"10.1007\/s11227-011-0704-3","volume":"63","author":"L Wang","year":"2011","unstructured":"Wang, L., Khan, S.U.: Review of performance metrics for green data centers: a taxonomy study. J. Supercomput. 63(3), 639\u2013656 (2011). doi:10.1007\/s11227-011-0704-3(2011)","journal-title":"J. Supercomput."},{"issue":"1","key":"9_CR9","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1177\/0143624412467196","volume":"34","author":"S Flucker","year":"2013","unstructured":"Flucker, S., Tozer, R.: Data centre energy efficiency analysis to minimize total cost of ownership. Building Serv. Eng. Res. Technol. 34(1), 103\u2013117 (2013)","journal-title":"Building Serv. Eng. Res. Technol."},{"key":"9_CR10","unstructured":"The Green Grid: Water Usage Effectiveness (WUE): A Green Grid Data Center Sustainability Metric. Technical report, White Paper #35, The Green Grid (2011)"},{"key":"9_CR11","unstructured":"The Green Grid: Carbon Usage Effectiveness (CUE): A Green Grid Data Center Sustainability Metric. Technical report, White Paper #32, The Green Grid (2010)"},{"issue":"12","key":"9_CR12","doi-asserted-by":"publisher","first-page":"3360","DOI":"10.1016\/j.enbuild.2011.08.034","volume":"43","author":"T Lu","year":"2011","unstructured":"Lu, T., L\u00fc, X., Remes, M., Viljanen, M.: Investigation of air management and energy performance in a data center in Finland: case study. Energy Build. 43(12), 3360\u20133372 (2011). doi:10.1016\/j.enbuild.2011.08.034","journal-title":"Energy Build."},{"key":"9_CR13","unstructured":"Sullivan, R.F.: Reducing bypass airflow is essential for eliminating computer room hot spots. Technical report, The Uptime Institute (2004)"},{"issue":"9","key":"9_CR14","doi-asserted-by":"publisher","first-page":"2145","DOI":"10.1016\/j.enbuild.2011.04.025","volume":"43","author":"J Cho","year":"2011","unstructured":"Cho, J., Kim, B.S.: Evaluation of air management system\u2019s thermal performance for superior cooling efficiency in high-density data centers. Energy Build. 43(9), 2145\u20132155 (2011)","journal-title":"Energy Build."},{"key":"9_CR15","doi-asserted-by":"crossref","unstructured":"Sharma, R.K., Bash, C.E., Patel, C.D.: Dimensionless parameters for evaluation of thermal design and performance of large-scale data centers. In: 8th ASME\/AIAA Joint Thermophysics and Heat Transfer Conference, pp. 1\u20131 (2002)","DOI":"10.2514\/6.2002-3091"},{"key":"9_CR16","doi-asserted-by":"crossref","unstructured":"Tang, Q., Mukherjee, T., Gupta, S.K., Cayton, P.: Sensor-based fast thermal evaluation model for energy efficient high-performance datacenters. In: Fourth International Conference on Intelligent Sensing and Information Processing, ICISIP 2006, pp. 203\u2013208. IEEE (2006)","DOI":"10.1109\/ICISIP.2006.4286097"},{"issue":"4.5","key":"9_CR17","doi-asserted-by":"publisher","first-page":"709","DOI":"10.1147\/rd.494.0709","volume":"49","author":"RR Schmidt","year":"2005","unstructured":"Schmidt, R.R., Cruz, E.E., Iyengar, M.: Challenges of data center thermal management. IBM J. Res. Dev. 49(4.5), 709\u2013723 (2005)","journal-title":"IBM J. Res. Dev."},{"issue":"2","key":"9_CR18","first-page":"725","volume":"111","author":"MK Herrlin","year":"2005","unstructured":"Herrlin, M.K.: Rack cooling effectiveness in data centers and telecom central offices: the rack cooling index (RCI). ASHRAE Trans. 111(2), 725\u2013731 (2005)","journal-title":"ASHRAE Trans."},{"issue":"1","key":"9_CR19","first-page":"63","volume":"115","author":"R Tozer","year":"2009","unstructured":"Tozer, R., Kurkjian, C., Salim, M.: Air management metrics in data centers. ASHRAE Trans. 115(1), 63\u201370 (2009)","journal-title":"ASHRAE Trans."},{"key":"9_CR20","unstructured":"Herrlin, M.K.: Improved data center energy efficiency and thermal performance by advanced airflow analysis. In: Digital Power Forum, pp. 10\u201312, San Francisco (2007)"},{"issue":"1","key":"9_CR21","first-page":"126","volume":"113","author":"JW Vangilder","year":"2007","unstructured":"Vangilder, J.W., Shrivastava, S.K.: Capture index: an airflow-based rack cooling performance metric. ASHRAE Trans. 113(1), 126\u2013136 (2007)","journal-title":"ASHRAE Trans."},{"key":"9_CR22","unstructured":"Pelley, S., Meisner, D., Wenisch, T.F., VanGilder, J.W.: Understanding and abstracting total data center power. In: Workshop on Energy-Efficient Design, June 2009"},{"key":"9_CR23","doi-asserted-by":"crossref","unstructured":"Chinnici, M., Quintiliani, A.: An example of methodology to assess energy efficiency improvements in datacenters. In: 2013 Third International Conference on Cloud and Green Computing (CGC), pp. 459\u2013463. IEEE, Karlsruhe (2013)","DOI":"10.1109\/CGC.2013.78"},{"key":"9_CR24","doi-asserted-by":"crossref","unstructured":"Mathew, P., Ganguly, S., Greenberg, S., Sartor, D.: Self-benchmarking guide for data centers: metrics, benchmarks, actions. Technical report, Lawrence Berkeley National Laboratory, Berkeley, California, June 2010","DOI":"10.2172\/983248"},{"key":"9_CR25","doi-asserted-by":"publisher","first-page":"154","DOI":"10.1016\/j.enbuild.2013.07.053","volume":"66","author":"B Durand-Estebe","year":"2013","unstructured":"Durand-Estebe, B., Le Bot, C., Mancos, J.N., Arquis, E.: Data center optimization using PID regulation in CFD simulations. Energy Build. 66, 154\u2013164 (2013)","journal-title":"Energy Build."},{"key":"9_CR26","doi-asserted-by":"crossref","unstructured":"Dumitru, I., Fagarasan, I., Iliescu, S., Said, Y.H., Ploix, S.: Increasing energy efficiency in data centers using energy management. In: 2011 IEEE\/ACM International Conference on Green Computing and Communications (GreenCom), pp. 159\u2013165. IEEE (2011)","DOI":"10.1109\/GreenCom.2011.53"},{"key":"9_CR27","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1016\/j.enbuild.2013.04.015","volume":"64","author":"J Yuventi","year":"2013","unstructured":"Yuventi, J., Mehdizadeh, R.: A critical analysis of power usage effectiveness and its use in communicating data center energy consumption. Energy Build. 64, 90\u201394 (2013)","journal-title":"Energy Build."},{"key":"9_CR28","unstructured":"The green grid: the green grid metrics: data center infrastructure efficiency (DCiE) detailed analysis. Technical report, White Paper #14, The Green Grid (2008)"},{"key":"9_CR29","unstructured":"The green grid: the green grid data center efficiency metrics: PUE and DCIE. Technical report, White Paper #6, The Green Grid (2007)"},{"key":"9_CR30","unstructured":"ETSI: Operational Energy Efficiency for User (OEU): Global KPI for Data Centers. Technical report, ETSI (2013)"},{"key":"9_CR31","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/j.enconman.2013.07.035","volume":"76","author":"GA Brady","year":"2013","unstructured":"Brady, G.A., Kapur, N., Summers, J.L., Thompson, H.M.: A case study and critical assessment in calculating power usage effectiveness for a data centre. Energy Convers. Manage. 76, 155\u2013161 (2013). doi:10.1016\/j.enconman.2013.07.035","journal-title":"Energy Convers. Manage."},{"key":"9_CR32","series-title":"Lecture Notes in Computer Science","doi-asserted-by":"publisher","first-page":"372","DOI":"10.1007\/978-3-642-38750-0_28","volume-title":"Supercomputing","author":"MK Patterson","year":"2013","unstructured":"Patterson, M.K., Poole, S.W., Hsu, C.-H., Maxwell, D., Tschudi, W., Coles, H., Martinez, D.J., Bates, N.: TUE, a new energy-efficiency metric applied at ORNL\u2019s Jaguar. In: Kunkel, J.M., Ludwig, T., Meuer, H.W. (eds.) ISC 2013. LNCS, vol. 7905, pp. 372\u2013382. Springer, Heidelberg (2013)"},{"key":"9_CR33","doi-asserted-by":"crossref","unstructured":"Patterson, M.K.: The effect of data center temperature on energy efficiency. In: 11th Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems, ITHERM 2008. pp. 1167\u20131174. IEEE (2008)","DOI":"10.1109\/ITHERM.2008.4544393"},{"key":"9_CR34","unstructured":"The Green Grid: The Green Grid Productivity Indicator. Technical report, White Paper #15, The Green Grid (2008)"},{"key":"9_CR35","unstructured":"The Green Grid: ERE: a Metric for Measuring the Benefit of Reuse Energy from a Data Center. Technical report, White Paper #29, The Green Grid (2010)"},{"key":"9_CR36","doi-asserted-by":"publisher","first-page":"270","DOI":"10.1016\/j.enbuild.2013.09.013","volume":"68","author":"J Cho","year":"2014","unstructured":"Cho, J., Yang, J., Park, W.: Evaluation of air distribution system\u2019s airflow performance for cooling energy savings in high-density data centers. Energy Build. 68, 270\u2013279 (2014)","journal-title":"Energy Build."},{"key":"9_CR37","doi-asserted-by":"publisher","unstructured":"Tang, Q., Gupta, S.K.S., Varsamopoulos, G.: Thermal-aware task scheduling for data centers through minimizing heat recirculation. In: 2007 IEEE International Conference on Cluster Computing, pp. 129\u2013138, (2007). doi:10.1109\/CLUSTR.2007.4629225","DOI":"10.1109\/CLUSTR.2007.4629225"},{"key":"9_CR38","unstructured":"Moss, D., Bean, J.H.: Energy impact of increased server inlet temperature. Technical report, APC White Paper, 138 (2009)"},{"key":"9_CR39","doi-asserted-by":"crossref","unstructured":"Biswas, S., Tiwari, M., Sherwood, T., Theogarajan, L., Chong, F.T.: Fighting fire with fire: modeling the datacenter-scale effects of targeted superlattice thermal management. In: 2011 38th Annual International Symposium on Computer Architecture (ISCA), pp. 331\u2013340. IEEE (2011)","DOI":"10.1145\/2000064.2000104"},{"key":"9_CR40","series-title":"Lecture Notes in Electrical Engineering","volume-title":"Proceedings of the 8th International Symposium on Heating, Ventilation and Air Conditioning","author":"F Favoino","year":"2014","unstructured":"Favoino, F., Capozzoli, A., Perino, M.: Temperature field real-time diagnosis by means of infrared imaging in data elaboration center. In: Abramowicz, W., Llorente, I.M., Surridge, M., Zisman, A., Vayssi\u00e8re, J. (eds.) Proceedings of the 8th International Symposium on Heating, Ventilation and Air Conditioning. LNEE, vol. 263. Springer, Heidelberg (2014)"},{"issue":"2","key":"9_CR41","doi-asserted-by":"publisher","first-page":"021401","DOI":"10.1115\/1.2787024","volume":"130","author":"AJ Shah","year":"2008","unstructured":"Shah, A.J., Carey, V.P., Bash, C.E., Patel, C.D.: Exergy analysis of data center thermal management systems. J. Heat Transf. 130(2), 021401 (2008). doi:10.1115\/1.2787024","journal-title":"J. Heat Transf."},{"issue":"4","key":"9_CR42","first-page":"04","volume":"5","author":"X Lu","year":"2011","unstructured":"Lu, X., Lu, T., Remes, M., Viljanen, M.: Preliminary analysis of energy efficiency in data center: case study. World Acad. Sci. Eng. Technol. 5(4), 04\u201326 (2011)","journal-title":"World Acad. Sci. Eng. Technol."},{"key":"9_CR43","doi-asserted-by":"publisher","first-page":"579","DOI":"10.1016\/j.ijheatmasstransfer.2013.03.037","volume":"62","author":"X Qian","year":"2013","unstructured":"Qian, X., Li, Z., Li, Z.: A thermal environmental analysis method for data centers. Int. J. Heat Mass Transf. 62, 579\u2013585 (2013)","journal-title":"Int. J. Heat Mass Transf."},{"issue":"13","key":"9_CR44","doi-asserted-by":"publisher","first-page":"2545","DOI":"10.1016\/j.ijheatmasstransfer.2006.11.034","volume":"50","author":"ZY Guo","year":"2007","unstructured":"Guo, Z.Y., Zhu, H.Y., Liang, X.G.: Entransy - a physical quantity describing heat transfer ability. Int. J. Heat Mass Transf. 50(13), 2545\u20132556 (2007)","journal-title":"Int. J. Heat Mass Transf."},{"issue":"1","key":"9_CR45","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1109\/MIC.2005.10","volume":"9","author":"RK Sharma","year":"2005","unstructured":"Sharma, R.K., Bash, C.E., Patel, C.D., Friedrich, R.J., Chase, J.S.: Balance of power: dynamic thermal management for internet data centers. Internet Comput. IEEE 9(1), 42\u201349 (2005)","journal-title":"Internet Comput. IEEE"},{"key":"9_CR46","unstructured":"Moore, J., Chase, J., Ranganathan, P., Sharma, R.: Making scheduling \u201ccool\u201d: temperature aware workload placement in data centers. Technical report, in USENIX Annual Technical Conference (2005)"},{"issue":"17","key":"9_CR47","doi-asserted-by":"publisher","first-page":"2888","DOI":"10.1016\/j.comnet.2009.06.008","volume":"53","author":"T Mukherjee","year":"2009","unstructured":"Mukherjee, T., Banerjee, A., Varsamopoulos, G., Gupta, S.K., Rungta, S.: Spatio-temporal thermal-aware job scheduling to minimize energy consumption in virtualized heterogeneous data centers. Comput. Netw. 53(17), 2888\u20132904 (2009)","journal-title":"Comput. Netw."}],"container-title":["Lecture Notes in Computer Science","Energy Efficient Data Centers"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-319-15786-3_9","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,2,20]],"date-time":"2023-02-20T22:43:35Z","timestamp":1676933015000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/978-3-319-15786-3_9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015]]},"ISBN":["9783319157856","9783319157863"],"references-count":47,"URL":"https:\/\/doi.org\/10.1007\/978-3-319-15786-3_9","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"type":"print","value":"0302-9743"},{"type":"electronic","value":"1611-3349"}],"subject":[],"published":{"date-parts":[[2015]]},"assertion":[{"value":"14 February 2015","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}}]}}