{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,30]],"date-time":"2025-05-30T21:40:02Z","timestamp":1748641202168,"version":"3.41.0"},"publisher-location":"Cham","reference-count":24,"publisher":"Springer International Publishing","isbn-type":[{"type":"print","value":"9783319196190"},{"type":"electronic","value":"9783319196206"}],"license":[{"start":{"date-parts":[[2015,1,1]],"date-time":"2015-01-01T00:00:00Z","timestamp":1420070400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2015]]},"DOI":"10.1007\/978-3-319-19620-6_31","type":"book-chapter","created":{"date-parts":[[2015,9,29]],"date-time":"2015-09-29T02:07:35Z","timestamp":1443492455000},"page":"247-256","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["A Portable Impedance Detector of Interdigitated Array Microelectrode for Rapid Detection of Avian Influenza Virus"],"prefix":"10.1007","author":[{"given":"Xiaohong","family":"Wang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhuo","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuhe","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jianhan","family":"Lin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2015,12,10]]},"reference":[{"key":"31_CR1","doi-asserted-by":"crossref","unstructured":"WHO, Human infection with avian influenza A(H5N1) virus \u2013 update (2014), http:\/\/www.who.int\/csr\/don\/2014_01_09_h5n1\/","DOI":"10.1128\/9781555815585.ch1"},{"issue":"2","key":"31_CR2","first-page":"132","volume":"23","author":"L. Miao","year":"2006","unstructured":"Miao, L., Liu, Z., Zhang, S.: Research Evolvement of Electrochemical Immunosensor. Chinese Journal of Medical Physics\u00a023(2), 132\u2013134 (2006)","journal-title":"Chinese Journal of Medical Physics"},{"issue":"1","key":"31_CR3","doi-asserted-by":"publisher","first-page":"204","DOI":"10.1016\/j.talanta.2011.01.001","volume":"84","author":"F. Xiao","year":"2011","unstructured":"Xiao, F., Zhang, N., Gu, H., et al.: A monoclonal antibody-based immunosensor for detection of Sudan I using electrochemical impedance spectroscopy. Talanta\u00a084(1), 204\u2013211 (2011)","journal-title":"Talanta"},{"issue":"5","key":"31_CR4","doi-asserted-by":"publisher","first-page":"1632","DOI":"10.1016\/j.talanta.2009.10.049","volume":"80","author":"Z. Li","year":"2010","unstructured":"Li, Z., Wang, Z., Sun, X., et al.: A sensitive and highly stable electrochemical impedance immunosensor based on the formation of silica gel\u2013ionic liquid biocompatible film on the glassy carbon electrode for the determination of aflatoxin B1 in bee pollen. Talanta\u00a080(5), 1632\u20131637 (2010)","journal-title":"Talanta"},{"issue":"14","key":"31_CR5","doi-asserted-by":"publisher","first-page":"4663","DOI":"10.1016\/j.electacta.2008.01.037","volume":"53","author":"P. Geng","year":"2008","unstructured":"Geng, P., Zhang, X., Meng, W., et al.: Self-assembled monolayers-based immunosensor for detection of Escherichia coli using electrochemical impedance spectroscopy. Electrochimica Acta\u00a053(14), 4663\u20134668 (2008)","journal-title":"Electrochimica Acta"},{"issue":"5","key":"31_CR6","first-page":"709","volume":"21","author":"D. Li","year":"2008","unstructured":"Li, D., Wang, J., Gai, L., Ying, Y., et al.: Rapid detection of Escherichia coli O157:H7 using electrochemical impedance immunosensor. Chinese Journal of Sensors and Actuators\u00a021(5), 709\u2013714 (2008)","journal-title":"Chinese Journal of Sensors and Actuators"},{"issue":"6","key":"31_CR7","first-page":"633","volume":"28","author":"H. Shi","year":"2009","unstructured":"Shi, H., Sun, X., Wang, H., et al.: Development of an Electrochemical Impedimetric Immunosensor for Determination of Microcystin-LR in Water. Journal of Instrumental Analysis\u00a028(6), 633\u2013637 (2009)","journal-title":"Journal of Instrumental Analysis"},{"issue":"3","key":"31_CR8","doi-asserted-by":"publisher","first-page":"1117","DOI":"10.1016\/j.electacta.2010.10.028","volume":"56","author":"X. Sun","year":"2011","unstructured":"Sun, X., Li, Z., Cai, Y., et al.: Electrochemical impedance spectroscopy for analytical determination of paraquat in meconium samples using an immunosensor modified with fullerene, ferrocene and ionic liquid. Electrochimica Acta\u00a056(3), 1117\u20131122 (2011)","journal-title":"Electrochimica Acta"},{"issue":"6-7","key":"31_CR9","doi-asserted-by":"publisher","first-page":"1256","DOI":"10.1166\/sl.2013.2870","volume":"11","author":"X. Yan","year":"2013","unstructured":"Yan, X., Wang, R., et al.: Impedance Immunosensor Based on Interdigitated Array Microelectrodes for Rapid Detection of Avian Influenza Virus Subtype H5. Sensor Letters\u00a011(6-7), 1256\u20131260 (2013)","journal-title":"Sensor Letters"},{"key":"31_CR10","first-page":"367","volume":"239","author":"X. Yan","year":"2013","unstructured":"Yan, X., Wang, M., Wen, X., et al.: Rapid detection of avian influenza virus using immunomagnetic separation and impedance measurement. Applied Mechanics and Materials\u00a0239, 367\u2013371 (2013)","journal-title":"Applied Mechanics and Materials"},{"issue":"1","key":"31_CR11","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1016\/S0022-0728(85)80008-5","volume":"191","author":"M. Ciszkowska","year":"1985","unstructured":"Ciszkowska, M., Stojek, Z.: Graphite multi-micro-disc based mercury film electrode: Comparison of experimental and theoretical anodic stripping results. Journal of Electroanalytical Chemistry and Interfacial Electrochemistry\u00a0191(1), 101\u2013110 (1985)","journal-title":"Journal of Electroanalytical Chemistry and Interfacial Electrochemistry"},{"issue":"1","key":"31_CR12","doi-asserted-by":"publisher","first-page":"433","DOI":"10.1016\/j.snb.2005.06.017","volume":"114","author":"H. Cai","year":"2006","unstructured":"Cai, H., Lee, T.M.-H., Hsing, I.-M.: Label-free protein recognition using an aptamer-based impedance measurement assay. Sensors and Actuators B: Chemical\u00a0114(1), 433\u2013437 (2006)","journal-title":"Sensors and Actuators B: Chemical"},{"issue":"2","key":"31_CR13","doi-asserted-by":"publisher","first-page":"250","DOI":"10.1016\/j.aca.2008.12.025","volume":"634","author":"Y.S. Kim","year":"2009","unstructured":"Kim, Y.S., Niazi, J.H., Gu, M.B.: Specific detection of oxytetracycline using DNA aptamer-immobilized interdigitated array electrode chip. Analytica Chimica Acta\u00a0634(2), 250\u2013254 (2009)","journal-title":"Analytica Chimica Acta"},{"issue":"9","key":"31_CR14","doi-asserted-by":"publisher","first-page":"724","DOI":"10.1002\/elan.200302872","volume":"16","author":"J. Min","year":"2004","unstructured":"Min, J., Baeumner, A.J.: Characterization and optimization of interdigitated ultramicroelectrode arrays as electrochemical biosensor transducers. Electroanalysis\u00a016(9), 724\u2013729 (2004)","journal-title":"Electroanalysis"},{"issue":"1","key":"31_CR15","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1016\/0956-5663(96)89087-7","volume":"12","author":"R. Ehret","year":"1997","unstructured":"Ehret, R., Baumann, W., Brischwein, M., et al.: Monitoring of cellular behaviour by impedance measurements on interdigitated electrode structures. Biosensors and Bioelectronics\u00a012(1), 29\u201341 (1997)","journal-title":"Biosensors and Bioelectronics"},{"issue":"2","key":"31_CR16","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1016\/S0925-4005(04)00414-9","volume":"105","author":"B.W. Chang","year":"2005","unstructured":"Chang, B.W., Chen, C.H., Ding, S.J., et al.: Impedimetric monitoring of cell attachment on interdigitated microelectrodes. Sensors and Actuators B: Chemical\u00a0105(2), 159\u2013163 (2005)","journal-title":"Sensors and Actuators B: Chemical"},{"issue":"3","key":"31_CR17","doi-asserted-by":"publisher","first-page":"173","DOI":"10.1002\/1521-4109(200103)13:3<173::AID-ELAN173>3.0.CO;2-B","volume":"13","author":"C. Berggren","year":"2001","unstructured":"Berggren, C., Bjarnason, B., Johansson, G.: Capacitive biosensors. Electroanalysis\u00a013(3), 173\u2013180 (2001)","journal-title":"Electroanalysis"},{"issue":"4","key":"31_CR18","doi-asserted-by":"publisher","first-page":"1107","DOI":"10.1021\/ac0352575","volume":"76","author":"L. Yang","year":"2004","unstructured":"Yang, L., Li, Y., Erf, G.F.: Interdigitated Array Microelectrode-Based Electrochemical Impedance Immunosensor for Detection of Escherichia coli O157: H7. Analytical Chemistry\u00a076(4), 1107\u20131113 (2004)","journal-title":"Analytical Chemistry"},{"issue":"5","key":"31_CR19","doi-asserted-by":"publisher","first-page":"1621","DOI":"10.1016\/j.talanta.2007.10.018","volume":"74","author":"L. Yang","year":"2008","unstructured":"Yang, L.: Electrical impedance spectroscopy for detection of bacterial cells in suspensions using interdigitated microelectrodes. Talanta\u00a074(5), 1621\u20131629 (2008)","journal-title":"Talanta"},{"issue":"8","key":"31_CR20","doi-asserted-by":"publisher","first-page":"1662","DOI":"10.1016\/j.bios.2004.07.021","volume":"20","author":"S.M. Radke","year":"2005","unstructured":"Radke, S.M., Alocilja, E.C.: A high density microelectrode array biosensor for detection of E. coli O157: H7. Biosensors and Bioelectronics\u00a020(8), 1662\u20131667 (2005)","journal-title":"Biosensors and Bioelectronics"},{"issue":"2","key":"31_CR21","doi-asserted-by":"publisher","first-page":"526","DOI":"10.1016\/j.snb.2007.02.048","volume":"125","author":"E. Valera","year":"2007","unstructured":"Valera, E., Ram\u00f3n-Azc\u00f3n, J., Rodr\u00edguez, \u00c1., et al.: Impedimetric immunosensor for atrazine detection using interdigitated \u03bc-electrodes (ID\u03bcE\u2019s). Sensors and Actuators B: Chemical\u00a0125(2), 526\u2013537 (2007)","journal-title":"Sensors and Actuators B: Chemical"},{"issue":"2","key":"31_CR22","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1016\/j.talanta.2009.03.017","volume":"79","author":"R. Wang","year":"2009","unstructured":"Wang, R., Wang, Y., Lassiter, K., et al.: Interdigitated array microelectrode based impedance immunosensor for detection of avian influenza virus H5N1. Talanta\u00a079(2), 159\u2013164 (2009)","journal-title":"Talanta"},{"key":"31_CR23","doi-asserted-by":"crossref","unstructured":"Wang, R., Li, Y., Mao, X., et al.: Magnetic bio-nanobeads and nanoelectrode based impedance biosensor for detection of avian influenza virus. In: Proceedings of IEEE Nano\/Molecular Medicine and Engineering (NANOMED), pp. 214\u2013217 (2010)","DOI":"10.1109\/NANOMED.2010.5749837"},{"key":"31_CR24","doi-asserted-by":"crossref","unstructured":"Lin, J., Lum, J., Wang, R., et al.: A portable impedance biosensor instrument for rapid detection of avian influenza virus. In: Proceedings of IEEE SENSORS 2010, pp. 1558\u20131563 (2010)","DOI":"10.1109\/ICSENS.2010.5690302"}],"container-title":["IFIP Advances in Information and Communication Technology","Computer and Computing Technologies in Agriculture VIII"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-319-19620-6_31","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,30]],"date-time":"2025-05-30T21:07:41Z","timestamp":1748639261000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-319-19620-6_31"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015]]},"ISBN":["9783319196190","9783319196206"],"references-count":24,"URL":"https:\/\/doi.org\/10.1007\/978-3-319-19620-6_31","relation":{},"ISSN":["1868-4238","1868-422X"],"issn-type":[{"type":"print","value":"1868-4238"},{"type":"electronic","value":"1868-422X"}],"subject":[],"published":{"date-parts":[[2015]]},"assertion":[{"value":"10 December 2015","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}}]}}