{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,6]],"date-time":"2025-10-06T17:52:51Z","timestamp":1759773171984,"version":"3.40.3"},"publisher-location":"Cham","reference-count":23,"publisher":"Springer International Publishing","isbn-type":[{"type":"print","value":"9783319437743"},{"type":"electronic","value":"9783319437750"}],"license":[{"start":{"date-parts":[[2016,1,1]],"date-time":"2016-01-01T00:00:00Z","timestamp":1451606400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2016]]},"DOI":"10.1007\/978-3-319-43775-0_17","type":"book-chapter","created":{"date-parts":[[2016,8,13]],"date-time":"2016-08-13T11:16:28Z","timestamp":1471086988000},"page":"186-197","source":"Crossref","is-referenced-by-count":15,"title":["Tactile Augmented Reality for Arteries Palpation in Open Surgery Training"],"prefix":"10.1007","author":[{"given":"Sara","family":"Condino","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rosanna Maria","family":"Viglialoro","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Simone","family":"Fani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Matteo","family":"Bianchi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Luca","family":"Morelli","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mauro","family":"Ferrari","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Antonio","family":"Bicchi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vincenzo","family":"Ferrari","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2016,8,14]]},"reference":[{"key":"17_CR1","unstructured":"Poorten, V.E., Demeester, E., Lammertse, P.: Haptic feedback for medical applications, a survey. In: Proceedings of the Actuator, pp. 18\u201320 (2012)"},{"key":"17_CR2","first-page":"213","volume":"119","author":"J Hu","year":"2006","unstructured":"Hu, J., Chang, C.Y., Tardella, N., Pratt, J., English, J.: Effectiveness of haptic feedback in open surgery simulation and training systems. Stud. Health Technol. 119, 213\u2013218 (2006)","journal-title":"Stud. Health Technol."},{"key":"17_CR3","doi-asserted-by":"crossref","first-page":"617","DOI":"10.1109\/TVCG.2012.46","volume":"18","author":"S Ullrich","year":"2012","unstructured":"Ullrich, S., Kuhlen, T.: Haptic palpation for medical simulation in virtual environments. IEEE Trans. Vis. Comput. Graph. 18, 617\u2013625 (2012)","journal-title":"IEEE Trans. Vis. Comput. Graph."},{"key":"17_CR4","doi-asserted-by":"crossref","unstructured":"Coles, T., John, N.W., Gould, D.A., Caldwell, D.G.: Haptic palpation for the femoral pulse in virtual interventional radiology. In: Second International Conferences on Advances in Computer-Human Interactions, ACHI 2009, pp. 193\u2013198 (2009)","DOI":"10.1109\/ACHI.2009.61"},{"key":"17_CR5","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1016\/j.cmpb.2013.05.014","volume":"111","author":"V Luboz","year":"2013","unstructured":"Luboz, V., Zhang, Y., Johnson, S., Song, Y., Kilkenny, C., Hunt, C., Woolnough, H., Guediri, S., Zhai, J., Odetoyinbo, T., Littler, P., Fisher, A., Hughes, C., Chalmers, N., Kessel, D., Clough, P.J., Ward, J., Phillips, R., How, T., Bulpitt, A., John, N.W., Bello, F., Gould, D.: ImaGiNe Seldinger: first simulator for Seldinger technique and angiography training. Comput. Methods Programs Biomed. 111, 419\u2013434 (2013)","journal-title":"Comput. Methods Programs Biomed."},{"key":"17_CR6","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1109\/TOH.2011.32","volume":"4","author":"TR Coles","year":"2011","unstructured":"Coles, T.R., John, N.W., Gould, D.A., Caldwell, D.G.: Integrating haptics with augmented reality in a femoral palpation and needle insertion training simulation. IEEE Trans. Haptics 4, 199\u2013209 (2011)","journal-title":"IEEE Trans. Haptics"},{"key":"17_CR7","series-title":"Lecture Notes in Computer Science","doi-asserted-by":"crossref","first-page":"504","DOI":"10.1007\/978-3-540-69057-3_64","volume-title":"Haptics: Perception, Devices and Scenarios","author":"T Iwamoto","year":"2008","unstructured":"Iwamoto, T., Tatezono, M., Shinoda, H.: Non-contact method for producing tactile sensation using airborne ultrasound. In: Ferre, M. (ed.) EuroHaptics 2008. LNCS, vol. 5024, pp. 504\u2013513. Springer, Heidelberg (2008)"},{"key":"17_CR8","series-title":"Lecture Notes in Computer Science","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1007\/978-3-319-12057-7_4","volume-title":"Biomedical Simulation","author":"GM Hung","year":"2014","unstructured":"Hung, G.M., John, N.W., Hancock, C., Hoshi, T.: Using and validating airborne ultrasound as a tactile interface within medical training simulators. In: Bello, F., Cotin, S. (eds.) ISBMS 2014. LNCS, vol. 8789, pp. 30\u201339. Springer, Heidelberg (2014)"},{"key":"17_CR9","doi-asserted-by":"crossref","unstructured":"Ferrari, V., Viglialoro, R.M., Nicoli, P., Cutolo, F., Condino, S., Carbone, M., Siesto, M., Ferrari, M.: Augmented reality visualization of deformable tubular structures for surgical simulation. Int. J. Med. Robot. Comput. Assist. Surg. 12, 231\u2013240 (2016)","DOI":"10.1002\/rcs.1681"},{"key":"17_CR10","series-title":"Lecture Notes in Computer Science","doi-asserted-by":"crossref","first-page":"428","DOI":"10.1007\/978-3-319-13969-2_33","volume-title":"Augmented and Virtual Reality","author":"R Maria Viglialoro","year":"2014","unstructured":"Maria Viglialoro, R., Condino, S., Gesi, M., Ferrari, M., Ferrari, V.: Augmented reality simulator for laparoscopic cholecystectomy training. In: De Paolis, L.T., Mongelli, A. (eds.) AVR 2014. LNCS, vol. 8853, pp. 428\u2013433. Springer, Heidelberg (2014)"},{"key":"17_CR11","doi-asserted-by":"crossref","unstructured":"Viglialoro, R., Condino, S., Gesi, M., Ferrari, M., Ferrari, V., Freschi, C., Cutolo, F.: AR visualization of \u201csynthetic Calot\u2019s triangle\u201d for training in cholecystectomy. In: 12th IASTED International Conference on Biomedical Engineering, BioMed 2016 (2016)","DOI":"10.2316\/P.2016.832-032"},{"key":"17_CR12","doi-asserted-by":"crossref","first-page":"493","DOI":"10.1002\/ca.22170","volume":"26","author":"S Abdalla","year":"2013","unstructured":"Abdalla, S., Pierre, S., Ellis, H.: Calot\u2019s triangle. Clin. Anat. 26, 493\u2013501 (2013)","journal-title":"Clin. Anat."},{"key":"17_CR13","doi-asserted-by":"crossref","unstructured":"Bianchi, M., Battaglia, E., Poggiani, M., Ciotti, S., Bicchi, A.: A wearable fabric-based display for haptic multi-cue delivery. In: 2016 IEEE Haptics Symposium (HAPTICS), pp. 277\u2013283 (2016)","DOI":"10.1109\/HAPTICS.2016.7463190"},{"key":"17_CR14","doi-asserted-by":"crossref","unstructured":"Bianchi, M., Scilingo, E.P., Serio, A., Bicchi, A.: A new softness display based on bi-elastic fabric. In: EuroHaptics Conference, 2009 and Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems, World Haptics 2009, Third Joint, pp. 382\u2013383 (2009)","DOI":"10.1109\/WHC.2009.4810905"},{"key":"17_CR15","doi-asserted-by":"crossref","unstructured":"Bianchi, M., Serio, A., Scilingo, E.P., Bicchi, A.: A new fabric-based softness display. In: 2010 IEEE Haptics Symposium, pp. 105\u2013112 (2010)","DOI":"10.1109\/HAPTIC.2010.5444668"},{"key":"17_CR16","doi-asserted-by":"crossref","unstructured":"Serio, A., Bianchi, M., Biechi, A.: A device for mimicking the contact force\/contact area relationship of different materials with applications to softness rendering. In: 2013 IEEE\/RSJ International Conference on Intelligent Robots and Systems, pp. 4484\u20134490 (2013)","DOI":"10.1109\/IROS.2013.6697001"},{"key":"17_CR17","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1109\/TOH.2015.2404353","volume":"8","author":"M Bianchi","year":"2015","unstructured":"Bianchi, M., Serio, A.: Design and characterization of a fabric-based softness display. IEEE Trans. Haptics 8, 152\u2013163 (2015)","journal-title":"IEEE Trans. Haptics"},{"key":"17_CR18","doi-asserted-by":"crossref","unstructured":"Minamizawa, K., Fukamachi, S., Kajimoto, H., Kawakami, N., Tachi, S.: Gravity grabber: wearable haptic display to present virtual mass sensation. In: ACM SIGGRAPH 2007 Emerging Technologies, San Diego, California, p. 8. ACM (2007)","DOI":"10.1145\/1278780.1278833"},{"key":"17_CR19","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1007\/978-3-540-78640-5_38","volume-title":"Bildverarbeitung f\u00fcr die Medizin 2008: Algorithmen \u2014 Systeme \u2014 Anwendungen Proceedings des Workshops vom 6. bis 8. April 2008 in Berlin","author":"S Ullrich","year":"2008","unstructured":"Ullrich, S., Mendoza, J., Ntouba, A., Rossaint, R., Kuhlen, T.: Haptic pulse simulation for virtual palpation. In: Tolxdorff, T., Braun, J., Deserno, T.M., Horsch, A., Handels, H., Meinzer, H.-P. (eds.) Bildverarbeitung f\u00fcr die Medizin 2008: Algorithmen \u2014 Systeme \u2014 Anwendungen Proceedings des Workshops vom 6. bis 8. April 2008 in Berlin, pp. 187\u2013191. Springer, Heidelberg (2008)"},{"key":"17_CR20","doi-asserted-by":"crossref","first-page":"640","DOI":"10.1093\/bja\/76.5.640","volume":"76","author":"E O\u2019Leary","year":"1996","unstructured":"O\u2019Leary, E., Hubbard, K., Tormey, W., Cunningham, A.J.: Laparoscopic cholecystectomy: haemodynamic and neuroendocrine responses after pneumoperitoneum and changes in position. Br. J. Anaesth. 76, 640\u2013644 (1996)","journal-title":"Br. J. Anaesth."},{"key":"17_CR21","doi-asserted-by":"crossref","unstructured":"Nafis, C., Jensen, V., Beauregard, L., Anderson, P.: Method for estimating dynamic EM tracking accuracy of surgical navigation tools - art. no. 61410K. In: Medical Imaging 2006: Visualization, Image-Guided Procedures, and Display, vol. 6141, pp. 152\u2013167 (2006)","DOI":"10.1117\/12.653448"},{"key":"17_CR22","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1157\/13071891","volume":"58","author":"D Bia","year":"2005","unstructured":"Bia, D., Aguirre, I., Zocalo, Y., Devera, L., Cabrera Fischer, E., Armentano, R.: Regional differences in viscosity, elasticity and wall buffering function in systemic arteries: pulse wave analysis of the arterial pressure-diameter relationship. Rev. Esp. Cardiol. 58, 167\u2013174 (2005)","journal-title":"Rev. Esp. Cardiol."},{"key":"17_CR23","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1161\/01.ATV.13.1.90","volume":"13","author":"A Benetos","year":"1993","unstructured":"Benetos, A., Laurent, S., Hoeks, A.P., Boutouyrie, P.H., Safar, M.E.: Arterial alterations with aging and high blood pressure. A noninvasive study of carotid and femoral arteries. Arterioscler. Thromb. J. Vasc. Biol.\/Am. Heart Assoc. 13, 90\u201397 (1993)","journal-title":"Arterioscler. Thromb. J. Vasc. Biol.\/Am. Heart Assoc."}],"container-title":["Lecture Notes in Computer Science","Medical Imaging and Augmented Reality"],"original-title":[],"link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-319-43775-0_17","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,9,12]],"date-time":"2019-09-12T10:47:05Z","timestamp":1568285225000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-319-43775-0_17"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016]]},"ISBN":["9783319437743","9783319437750"],"references-count":23,"URL":"https:\/\/doi.org\/10.1007\/978-3-319-43775-0_17","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"type":"print","value":"0302-9743"},{"type":"electronic","value":"1611-3349"}],"subject":[],"published":{"date-parts":[[2016]]}}}