{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,3,28]],"date-time":"2025-03-28T05:11:15Z","timestamp":1743138675970,"version":"3.40.3"},"publisher-location":"Cham","reference-count":20,"publisher":"Springer International Publishing","isbn-type":[{"type":"print","value":"9783319467191"},{"type":"electronic","value":"9783319467207"}],"license":[{"start":{"date-parts":[[2016,1,1]],"date-time":"2016-01-01T00:00:00Z","timestamp":1451606400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2016,1,1]],"date-time":"2016-01-01T00:00:00Z","timestamp":1451606400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2016]]},"DOI":"10.1007\/978-3-319-46720-7_41","type":"book-chapter","created":{"date-parts":[[2016,10,1]],"date-time":"2016-10-01T03:01:32Z","timestamp":1475290892000},"page":"353-361","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["3D Ultrasonic Needle Tracking with a 1.5D Transducer Array for Guidance of Fetal Interventions"],"prefix":"10.1007","author":[{"given":"Wenfeng","family":"Xia","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Simeon J.","family":"West","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jean-Martial","family":"Mari","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sebastien","family":"Ourselin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anna L.","family":"David","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Adrien E.","family":"Desjardins","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2016,10,2]]},"reference":[{"issue":"6","key":"41_CR1","doi-asserted-by":"publisher","first-page":"655","DOI":"10.1016\/S0002-9378(85)80254-4","volume":"153","author":"F Daffos","year":"1985","unstructured":"Daffos, F., et al.: Fetal blood, sampling during pregnancy with use of a needle guided by ultrasound: a study of 606 consecutive cases. Am. J. Obstet. Gynecol. 153(6), 655\u2013660 (1985)","journal-title":"Am. J. Obstet. Gynecol."},{"issue":"2","key":"41_CR2","doi-asserted-by":"publisher","first-page":"128","DOI":"10.1002\/uog.10152","volume":"40","author":"K Agarwal","year":"2012","unstructured":"Agarwal, K., et al.: Pregnancy loss after chorionic villus sampling and genetic amniocentesis in twin pregnancies: a systematic review. Ultrasound Obstet. Gynecol. 40(2), 128\u2013134 (2012)","journal-title":"Ultrasound Obstet. Gynecol."},{"issue":"2","key":"41_CR3","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1097\/AAP.0b013e31820d4349","volume":"36","author":"S Hebard","year":"2011","unstructured":"Hebard, S., et al.: Echogenic technology can improve needle visibility during ultrasound-guided regional anesthesia. Reg. Anesth. Pain Med. 36(2), 185\u2013189 (2011)","journal-title":"Reg. Anesth. Pain Med."},{"key":"41_CR4","doi-asserted-by":"publisher","first-page":"1858","DOI":"10.1213\/01.ane.0000286814.79988.0a","volume":"105","author":"SM Klein","year":"2007","unstructured":"Klein, S.M., et al.: Piezoelectric vibrating needle and catheter for enhancing ultrasoundguided peripheral nerve blocks. Anesth. Analg. 105, 1858\u20131860 (2007)","journal-title":"Anesth. Analg."},{"issue":"1","key":"41_CR5","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1177\/016173461103300101","volume":"33","author":"V Rotemberg","year":"2011","unstructured":"Rotemberg, V., et al.: Acoustic radiation force impulse (ARFI) imaging-based needle visualization. Ultrason. Imaging 33(1), 1\u201316 (2011)","journal-title":"Ultrason. Imaging"},{"issue":"6","key":"41_CR6","doi-asserted-by":"publisher","first-page":"1355","DOI":"10.1109\/TUFFC.2008.798","volume":"55","author":"MP Fronheiser","year":"2008","unstructured":"Fronheiser, M.P., et al.: Vibrating interventional device detection using real-time 3-D color doppler. IEEE Trans. Ultrason. Ferroelectr. Freq. Control 55(6), 1355\u20131362 (2008)","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"issue":"8","key":"41_CR7","doi-asserted-by":"publisher","first-page":"086005","DOI":"10.1117\/1.JBO.20.8.086005","volume":"20","author":"W Xia","year":"2015","unstructured":"Xia, W., et al.: Performance characteristics of an interventional multispectral photoacoustic imaging system for guiding minimally invasive procedures. J. Biomed. Opt. 20(8), 086005 (2015)","journal-title":"J. Biomed. Opt."},{"key":"41_CR8","doi-asserted-by":"publisher","first-page":"733","DOI":"10.1016\/S0021-9290(02)00036-2","volume":"35","author":"F Poulin","year":"2002","unstructured":"Poulin, F.: Interference during the use of an electromagnetic tracking system under OR conditions. J. Biomech. 35, 733\u2013737 (2002)","journal-title":"J. Biomech."},{"key":"41_CR9","doi-asserted-by":"crossref","unstructured":"Guo, X., et al.: Photoacoustic active ultrasound element for catheter tracking. In: Proceedings of SPIE, vol. 8943, p. 89435M (2014)","DOI":"10.1117\/12.2041625"},{"key":"41_CR10","series-title":"Lecture Notes in Computer Science","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1007\/978-3-319-24553-9_46","volume-title":"Medical Image Computing and Computer-Assisted Intervention \u2013 MICCAI 2015","author":"W Xia","year":"2015","unstructured":"Xia, W., et al.: Interventional photoacoustic imaging of the human placenta with ultrasonic tracking for minimally invasive fetal surgeries. In: Navab, N., Hornegger, J., Wells, W.M., Frangi, A.F. (eds.) MICCAI 2015. LNCS, vol. 9349, pp. 371\u2013378. Springer, Heidelberg (2015). doi:10.1007\/978-3-319-24553-9_46"},{"issue":"10","key":"41_CR11","doi-asserted-by":"publisher","first-page":"5983","DOI":"10.1118\/1.4931418","volume":"42","author":"W Xia","year":"2015","unstructured":"Xia, W., et al.: In-plane ultrasonic needle tracking using a fiber-optic hydrophone. Med. Phys. 42(10), 5983\u20135991 (2015)","journal-title":"Med. Phys."},{"issue":"7","key":"41_CR12","doi-asserted-by":"publisher","first-page":"4065","DOI":"10.1118\/1.4953205","volume":"43","author":"W Xia","year":"2016","unstructured":"Xia, W., et al.: Coded excitation ultrasonic needle tracking: an in vivo study. Med. Phys. 43(7), 4065\u20134073 (2016)","journal-title":"Med. Phys."},{"key":"41_CR13","doi-asserted-by":"crossref","unstructured":"Nikolov, S.I.: Precision of needle tip localization using a receiver in the needle. In: IEEE International Ultrasonics Symposium Proceedings, Beijing, pp. 479\u2013482 (2008)","DOI":"10.1109\/ULTSYM.2008.0117"},{"key":"41_CR14","series-title":"Lecture Notes in Computer Science","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1007\/978-3-642-23623-5_20","volume-title":"Medical Image Computing and Computer-Assisted Intervention \u2013 MICCAI 2011","author":"J Mung","year":"2011","unstructured":"Mung, J., et al.: A non-disruptive technology for robust 3D tool tracking for ultrasound-guided interventions. In: Fichtinger, G., Martel, A., Peters, T. (eds.) MICCAI 2011. LNCS, vol. 6891, pp. 153\u2013160. Springer, Heidelberg (2011). doi:10.1007\/978-3-642-23623-5_20"},{"key":"41_CR15","doi-asserted-by":"crossref","unstructured":"Mung, J.: Ultrasonically marked instruments for ultrasound-guided interventions. In: IEEE Ultrasonics Symposium (IUS), pp. 2053\u20132056 (2013)","DOI":"10.1109\/ULTSYM.2013.0524"},{"issue":"6","key":"41_CR16","doi-asserted-by":"publisher","first-page":"3611","DOI":"10.1121\/1.3117437","volume":"125","author":"P Morris","year":"2009","unstructured":"Morris, P., et al.: A Fabry-P$${\\rm \\acute{e}}$$rot fiber-optic ultrasonic hydrophone for the simultaneous measurement of temperature and acoustic pressure. J. Acoust. Soc. Am. 125(6), 3611\u20133622 (2009)","journal-title":"J. Acoust. Soc. Am."},{"issue":"13","key":"41_CR17","doi-asserted-by":"publisher","first-page":"881","DOI":"10.1049\/el:19900576","volume":"26","author":"SZ Budisin","year":"1990","unstructured":"Budisin, S.Z., et al.: New complementary pairs of sequences. Electron. Lett. 26(13), 881\u2013883 (1990)","journal-title":"Electron. Lett."},{"key":"41_CR18","doi-asserted-by":"publisher","first-page":"419","DOI":"10.1089\/hum.2010.007","volume":"22","author":"AL David","year":"2011","unstructured":"David, A.L., et al.: Recombinant adeno-associated virus-mediated in utero gene transfer gives therapeutic transgene expression in the sheep. Hum. Gene Ther. 22, 419\u2013426 (2011)","journal-title":"Hum. Gene Ther."},{"issue":"4","key":"41_CR19","doi-asserted-by":"publisher","first-page":"280","DOI":"10.5114\/jcb.2015.54062","volume":"7","author":"S Boutaleb","year":"2015","unstructured":"Boutaleb, S., et al.: Performance and suitability assessment of a real-time 3D electromagnetic needle tracking system for interstitial brachytherapy. J. Contemp. Brachyther. 7(4), 280\u2013289 (2015)","journal-title":"J. Contemp. Brachyther."},{"key":"41_CR20","doi-asserted-by":"crossref","unstructured":"Zhang, E.Z., Beard, P.C.: A miniature all-optical photoacoustic imaging probe. In: Proceedings of SPIE, p. 78991F (2011). http:\/\/proceedings.spiedigitallibrary.org\/proceeding.aspx?articleid=1349009","DOI":"10.1117\/12.874883"}],"container-title":["Lecture Notes in Computer Science","Medical Image Computing and Computer-Assisted Intervention \u2013 MICCAI 2016"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-319-46720-7_41","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,10,4]],"date-time":"2021-10-04T21:43:17Z","timestamp":1633383797000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/978-3-319-46720-7_41"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016]]},"ISBN":["9783319467191","9783319467207"],"references-count":20,"URL":"https:\/\/doi.org\/10.1007\/978-3-319-46720-7_41","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"type":"print","value":"0302-9743"},{"type":"electronic","value":"1611-3349"}],"subject":[],"published":{"date-parts":[[2016]]},"assertion":[{"value":"2 October 2016","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}},{"value":"MICCAI","order":1,"name":"conference_acronym","label":"Conference Acronym","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"International Conference on Medical Image Computing and Computer-Assisted Intervention","order":2,"name":"conference_name","label":"Conference Name","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Athens","order":3,"name":"conference_city","label":"Conference City","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Greece","order":4,"name":"conference_country","label":"Conference Country","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2016","order":5,"name":"conference_year","label":"Conference Year","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"17 October 2016","order":7,"name":"conference_start_date","label":"Conference Start Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"21 October 2016","order":8,"name":"conference_end_date","label":"Conference End Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"19","order":9,"name":"conference_number","label":"Conference Number","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"miccai2016","order":10,"name":"conference_id","label":"Conference ID","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"This content has been made available to all.","name":"free","label":"Free to read"}]}}