{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,3,28]],"date-time":"2025-03-28T09:53:50Z","timestamp":1743155630576,"version":"3.40.3"},"publisher-location":"Cham","reference-count":15,"publisher":"Springer International Publishing","isbn-type":[{"type":"print","value":"9783319550763"},{"type":"electronic","value":"9783319550770"}],"license":[{"start":{"date-parts":[[2017,9,9]],"date-time":"2017-09-09T00:00:00Z","timestamp":1504915200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018]]},"DOI":"10.1007\/978-3-319-55077-0_18","type":"book-chapter","created":{"date-parts":[[2017,9,11]],"date-time":"2017-09-11T15:31:22Z","timestamp":1505143882000},"page":"135-141","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Surface Plasmon Resonance Sensor in Plastic Optical Fibers. Influence of the Mechanical Support Geometry on the Performances"],"prefix":"10.1007","author":[{"given":"Nunzio","family":"Cennamo","sequence":"first","affiliation":[]},{"given":"Letizia","family":"De Maria","sequence":"additional","affiliation":[]},{"given":"Cristina","family":"Chemelli","sequence":"additional","affiliation":[]},{"given":"Maria","family":"Pesavento","sequence":"additional","affiliation":[]},{"given":"Antonella","family":"Profumo","sequence":"additional","affiliation":[]},{"given":"Ramona","family":"Galatus","sequence":"additional","affiliation":[]},{"given":"Luigi","family":"Zeni","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2017,9,9]]},"reference":[{"key":"18_CR1","first-page":"105","volume":"50","author":"R Narayanaswamy","year":"2006","unstructured":"R. Narayanaswamy, Optical chemical sensors and biosensors for food safety and security applications. Acta. Biol. Szeged 50, 105\u2013108 (2006)","journal-title":"Acta. Biol. Szeged"},{"key":"18_CR2","doi-asserted-by":"publisher","first-page":"4423","DOI":"10.1016\/j.bios.2011.04.056","volume":"26","author":"EM Munoz","year":"2011","unstructured":"E.M. Munoz, S. Lorenzo-Abalde, \u00c1. Gonz\u00e1lez-Fern\u00e1ndez et al., Direct surface plasmon resonance immunosensor for in situ detection of benzoylecgonine, the major cocaine metabolite. Biosens. Bioelectron. 26, 4423\u20134428 (2011)","journal-title":"Biosens. Bioelectron."},{"key":"18_CR3","doi-asserted-by":"publisher","first-page":"873","DOI":"10.1007\/s00216-007-1725-x","volume":"390","author":"D Habauzit","year":"2008","unstructured":"D. Habauzit, J. Armengaud, B. Roig, J. Chopineau, Determination of estrogen presence in water by SPR using estrogen receptor dimerization. Anal. Bioanal. Chem. 390, 873\u2013883 (2008)","journal-title":"Anal. Bioanal. Chem."},{"key":"18_CR4","doi-asserted-by":"publisher","first-page":"528","DOI":"10.1007\/s00216-003-2101-0","volume":"377","author":"J Homola","year":"2003","unstructured":"J. Homola, Present and future of surface plasmon resonance biosensors. Anal. Bioanal. Chem. 377, 528\u2013539 (2003)","journal-title":"Anal. Bioanal. Chem."},{"key":"18_CR5","doi-asserted-by":"publisher","first-page":"536","DOI":"10.1016\/j.snb.2016.02.074","volume":"230","author":"A Gowri","year":"2016","unstructured":"A. Gowri, V.V.R. Sai, Development of LSPR based U-bent plastic optical fiber sensors. Sens. Actuators B 230, 536\u2013543 (2016)","journal-title":"Sens. Actuators B"},{"key":"18_CR6","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1088\/0963-9659\/5\/2\/006","volume":"5","author":"A Trouillet","year":"1996","unstructured":"A. Trouillet, C. Ronot-Trioli, C. Veillas, H. Gagnaire, Chemical sensing by surface plasmon resonance in a multimode optical fibre. Pure Appl. Opt. 5, 227\u2013237 (1996)","journal-title":"Pure Appl. Opt."},{"key":"18_CR7","doi-asserted-by":"publisher","first-page":"1118","DOI":"10.1109\/JSEN.2007.897946","volume":"7","author":"K Anuj","year":"2007","unstructured":"K. Anuj, R.J. Sharma, B.D. Gupta, Fiber-optic sensors based on surface plasmon resonance: a comprehensive review. IEEE Sens. J 7, 1118\u20131129 (2007)","journal-title":"IEEE Sens. J"},{"key":"18_CR8","doi-asserted-by":"publisher","first-page":"487","DOI":"10.1021\/ac303159b","volume":"85","author":"XD Wang","year":"2013","unstructured":"X.D. Wang, O.S. Wolfbeis, Fiber-Optic Chemical Sensors and Biosensors (2008\u20132012). Anal. Chem. 85, 487\u2013508 (2013)","journal-title":"Anal. Chem."},{"key":"18_CR9","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1016\/j.snb.2013.07.005","volume":"188","author":"N Cennamo","year":"2013","unstructured":"N. Cennamo, G. D\u2019Agostino, R. Galatus, L. Bibb\u00f2, M. Pesavento, L. Zeni, Sensors based on surface plasmon resonance in a plastic optical fiber for the detection of trinitrotoluene. Sens. Actuators B 188, 221\u2013226 (2013)","journal-title":"Sens. Actuators B"},{"key":"18_CR10","doi-asserted-by":"publisher","first-page":"529","DOI":"10.1016\/j.snb.2013.10.067","volume":"191","author":"N Cennamo","year":"2014","unstructured":"N. Cennamo, G. D\u2019Agostino, M. Pesavento, L. Zeni, High selectivity and sensitivity sensor based on MIP and SPR in tapered plastic optical fibers for the detection of L-nicotine. Sens. Actuators B 191, 529\u2013536 (2014)","journal-title":"Sens. Actuators B"},{"key":"18_CR11","doi-asserted-by":"publisher","first-page":"8499","DOI":"10.3390\/s150408499","volume":"15","author":"N Cennamo","year":"2015","unstructured":"N. Cennamo, L. De Maria, G. D\u2019Agostino, L. Zeni, M. Pesavento, Monitoring of low levels of furfural in power transformer oil with a sensor system based on a POF-MIP platform. Sensors 15, 8499\u20138511 (2015)","journal-title":"Sensors"},{"key":"18_CR12","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1016\/j.bios.2015.07.013","volume":"76","author":"L Uzun","year":"2016","unstructured":"L. Uzun, A.P.F. Turner, Molecularly-imprinted polymers sensors: realising their potential. Biosens. Bioelectron. 76, 131\u2013144 (2016)","journal-title":"Biosens. Bioelectron."},{"key":"18_CR13","doi-asserted-by":"publisher","first-page":"11752","DOI":"10.3390\/s111211752","volume":"11","author":"N Cennamo","year":"2011","unstructured":"N. Cennamo, D. Massarotti, L. Conte, L. Zeni, Low cost sensors based on SPR in plastic optical fiber for biosensor implementation. Sensors 11, 11752\u201311760 (2011)","journal-title":"Sensors"},{"key":"18_CR14","doi-asserted-by":"publisher","first-page":"363","DOI":"10.1016\/j.snb.2004.08.017","volume":"106","author":"M Iga","year":"2005","unstructured":"M. Iga, A. Sekib, K. Watanabe, Gold thickness dependence of SPR-based hetero-core structured optical fiber sensor. Sens. Actuators B Chem. 106, 363\u2013368 (2005)","journal-title":"Sens. Actuators B Chem."},{"key":"18_CR15","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1007\/s11468-008-9055-1","volume":"3","author":"M Kanso","year":"2008","unstructured":"M. Kanso, S. Cuenot, G. Louarn, Sensitivity of optical fiber sensor based on surface plasmon resonance: Modeling and experiments. Plasmonics 3, 49\u201357 (2008)","journal-title":"Plasmonics"}],"container-title":["Lecture Notes in Electrical Engineering","Sensors"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-319-55077-0_18","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,21]],"date-time":"2019-05-21T13:10:00Z","timestamp":1558444200000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-319-55077-0_18"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,9,9]]},"ISBN":["9783319550763","9783319550770"],"references-count":15,"URL":"https:\/\/doi.org\/10.1007\/978-3-319-55077-0_18","relation":{},"ISSN":["1876-1100","1876-1119"],"issn-type":[{"type":"print","value":"1876-1100"},{"type":"electronic","value":"1876-1119"}],"subject":[],"published":{"date-parts":[[2017,9,9]]},"assertion":[{"value":"9 September 2017","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}},{"value":"CNS","order":1,"name":"conference_acronym","label":"Conference Acronym","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Convegno Nazionale Sensori","order":2,"name":"conference_name","label":"Conference Name","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Rome","order":3,"name":"conference_city","label":"Conference City","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Italy","order":4,"name":"conference_country","label":"Conference Country","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2016","order":5,"name":"conference_year","label":"Conference Year","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"23 February 2016","order":7,"name":"conference_start_date","label":"Conference Start Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"25 February 2016","order":8,"name":"conference_end_date","label":"Conference End Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"3","order":9,"name":"conference_number","label":"Conference Number","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"cns2016","order":10,"name":"conference_id","label":"Conference ID","group":{"name":"ConferenceInfo","label":"Conference Information"}}]}}