{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,22]],"date-time":"2026-02-22T10:04:22Z","timestamp":1771754662393,"version":"3.50.1"},"publisher-location":"Cham","reference-count":27,"publisher":"Springer International Publishing","isbn-type":[{"value":"9783319623948","type":"print"},{"value":"9783319623955","type":"electronic"}],"license":[{"start":{"date-parts":[[2017,1,1]],"date-time":"2017-01-01T00:00:00Z","timestamp":1483228800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2017]]},"DOI":"10.1007\/978-3-319-62395-5_44","type":"book-chapter","created":{"date-parts":[[2017,7,6]],"date-time":"2017-07-06T00:52:59Z","timestamp":1499302379000},"page":"635-651","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Sub-hour Unit Commitment MILP Model with\u00a0Benchmark Problem Instances"],"prefix":"10.1007","author":[{"given":"Paula","family":"Carroll","sequence":"first","affiliation":[]},{"given":"Damian","family":"Flynn","sequence":"additional","affiliation":[]},{"given":"Bernard","family":"Fortz","sequence":"additional","affiliation":[]},{"given":"Alex","family":"Melhorn","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2017,7,7]]},"reference":[{"issue":"3","key":"44_CR1","doi-asserted-by":"publisher","first-page":"1098","DOI":"10.1109\/59.871739","volume":"15","author":"J Arroyo","year":"2000","unstructured":"Arroyo, J., Conejo, A.: Optimal response of a thermal unit to an electricity spot market. IEEE Trans. Power Syst. 15(3), 1098\u20131104 (2000)","journal-title":"IEEE Trans. Power Syst."},{"issue":"1","key":"44_CR2","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1109\/TPWRS.2012.2205021","volume":"28","author":"D Bertsimas","year":"2013","unstructured":"Bertsimas, D., Litvinov, E., Sun, X., Zhao, J., Zheng, T.: Adaptive robust optimization for the security constrained unit commitment problem. IEEE Trans. Power Syst. 28(1), 52\u201363 (2013)","journal-title":"IEEE Trans. Power Syst."},{"issue":"5","key":"44_CR3","doi-asserted-by":"publisher","first-page":"1038","DOI":"10.1214\/aos\/1176343239","volume":"3","author":"PJ Bickel","year":"1975","unstructured":"Bickel, P.J., Lehmann, E.L.: Descriptive statistics for nonparametric models I. Introduction. Ann. Stat. 3(5), 1038\u20131044 (1975)","journal-title":"Ann. Stat."},{"issue":"1","key":"44_CR4","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1016\/j.disopt.2006.10.007","volume":"4","author":"D Bienstock","year":"2007","unstructured":"Bienstock, D., Mattia, S.: Using mixed-integer programming to solve power grid blackout problems. Discrete Optim. 4(1), 115\u2013141 (2007)","journal-title":"Discrete Optim."},{"issue":"3","key":"44_CR5","doi-asserted-by":"publisher","first-page":"1371","DOI":"10.1109\/TPWRS.2006.876672","volume":"21","author":"M Carrion","year":"2006","unstructured":"Carrion, M., Arroyo, J.: A computationally efficient mixed-integer linear formulation for the thermal unit commitment problem. IEEE Trans. Power Syst. 21(3), 1371\u20131378 (2006)","journal-title":"IEEE Trans. Power Syst."},{"key":"44_CR6","unstructured":"CER: Validated 2011\u201312 sem generator data parameters. Technical report, Commission for Energy Regulation (2011). http:\/\/www.allislandproject.org\/en\/market_decision_documents.aspx?page=4&article=151a9561-cef9-47f2-9f48-21f6c62cef34. Accessed Nov 2013"},{"issue":"2","key":"44_CR7","doi-asserted-by":"publisher","first-page":"707","DOI":"10.1109\/59.867163","volume":"15","author":"CP Cheng","year":"2000","unstructured":"Cheng, C.P., Liu, C.W., Liu, C.C.: Unit commitment by Lagrangian relaxation and genetic algorithms. IEEE Trans. Power Syst. 15(2), 707\u2013714 (2000)","journal-title":"IEEE Trans. Power Syst."},{"issue":"2","key":"44_CR8","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1109\/MPER.1983.5519636","volume":"3","author":"AI Cohen","year":"1983","unstructured":"Cohen, A.I., Yoshimura, M.: A branch-and-bound algorithm for unit commitment. Power Eng. Rev. IEEE PER 3(2), 34\u201335 (1983)","journal-title":"Power Eng. Rev. IEEE PER"},{"issue":"6","key":"44_CR9","doi-asserted-by":"publisher","first-page":"2154","DOI":"10.1109\/TPAS.1978.354719","volume":"97","author":"T Dillon","year":"1978","unstructured":"Dillon, T., Edwin, K.W., Kochs, H.D., Taud, R.J.: Integer programming approach to the problem of optimal unit commitment with probabilistic reserve determination. IEEE Trans. Power Appar. Syst. PAS 97(6), 2154\u20132166 (1978)","journal-title":"IEEE Trans. Power Appar. Syst. PAS"},{"issue":"2","key":"44_CR10","doi-asserted-by":"publisher","first-page":"587","DOI":"10.1109\/TPWRS.2005.846206","volume":"20","author":"R Doherty","year":"2005","unstructured":"Doherty, R., O\u2019Malley, M.: A new approach to quantify reserve demand in systems with significant installed wind capacity. IEEE Trans. Power Syst. 20(2), 587\u2013595 (2005)","journal-title":"IEEE Trans. Power Syst."},{"key":"44_CR11","unstructured":"Eirgrid: System performance data (2016). http:\/\/smartgriddashboard.eirgrid.com. Accessed Mar 2017"},{"key":"44_CR12","doi-asserted-by":"crossref","unstructured":"Hedman, K., O\u2019Neill, R., Oren, S.: Analyzing valid inequalities of the generation unit commitment problem. In: Power Systems Conference and Exposition, PSCE 2009, pp. 1\u20136. IEEE\/PES (2009)","DOI":"10.1109\/PSCE.2009.4840214"},{"issue":"4","key":"44_CR13","doi-asserted-by":"publisher","first-page":"1452","DOI":"10.1109\/59.801925","volume":"14","author":"KA Juste","year":"1999","unstructured":"Juste, K.A., Kita, H., Tanaka, E., Hasegawa, J.: An evolutionary programming solution to the unit commitment problem. IEEE Trans. Power Syst. 14(4), 1452\u20131459 (1999)","journal-title":"IEEE Trans. Power Syst."},{"issue":"1","key":"44_CR14","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1109\/59.485989","volume":"11","author":"S Kazarlis","year":"1996","unstructured":"Kazarlis, S., Bakirtzis, A., Petridis, V.: A genetic algorithm solution to the unit commitment problem. IEEE Trans. Power Syst. 11(1), 83\u201392 (1996)","journal-title":"IEEE Trans. Power Syst."},{"issue":"4","key":"44_CR15","doi-asserted-by":"publisher","first-page":"769","DOI":"10.1109\/TSTE.2012.2209210","volume":"3","author":"J Kiviluoma","year":"2012","unstructured":"Kiviluoma, J., Meibom, P., Tuohy, A., Troy, N., Milligan, M., Lange, B., Gibescu, M., O\u2019Malley, M.: Short-term energy balancing with increasing levels of wind energy. IEEE Trans. Sustain. Energy 3(4), 769\u2013776 (2012)","journal-title":"IEEE Trans. Sustain. Energy"},{"key":"44_CR16","doi-asserted-by":"publisher","first-page":"240","DOI":"10.1016\/j.enbuild.2012.01.037","volume":"48","author":"F McLoughlin","year":"2012","unstructured":"McLoughlin, F., Duffy, A., Conlon, M.: Characterising domestic electricity consumption patterns by dwelling and occupant socio-economic variables: an Irish case study. Energy Build. 48, 240\u2013248 (2012)","journal-title":"Energy Build."},{"issue":"5","key":"44_CR17","doi-asserted-by":"publisher","first-page":"1218","DOI":"10.1109\/TPAS.1983.318063","volume":"102","author":"A Merlin","year":"1983","unstructured":"Merlin, A., Sandrin, P.: A new method for unit commitment at electricite de France. IEEE Trans. Power Appar. Syst. PAS 102(5), 1218\u20131225 (1983)","journal-title":"IEEE Trans. Power Appar. Syst. PAS"},{"issue":"3","key":"44_CR18","doi-asserted-by":"publisher","first-page":"578","DOI":"10.1287\/opre.2013.1174","volume":"61","author":"A Papavasiliou","year":"2013","unstructured":"Papavasiliou, A., Oren, S.S.: Multiarea stochastic unit commitment for high wind penetration in a transmission constrained network. Oper. Res. 61(3), 578\u2013592 (2013)","journal-title":"Oper. Res."},{"issue":"1","key":"44_CR19","doi-asserted-by":"publisher","first-page":"128","DOI":"10.1109\/59.317549","volume":"9","author":"G Sheble","year":"1994","unstructured":"Sheble, G., Fahd, G.: Unit commitment literature synopsis. IEEE Trans. Power Syst. 9(1), 128\u2013135 (1994)","journal-title":"IEEE Trans. Power Syst."},{"issue":"2","key":"44_CR20","doi-asserted-by":"publisher","first-page":"339","DOI":"10.1109\/TPWRS.1987.4335130","volume":"2","author":"WL Snyder","year":"1987","unstructured":"Snyder, W.L., Powell, H., Rayburn, J.C.: Dynamic programming approach to unit commitment. IEEE Trans. Power Syst. 2(2), 339\u2013348 (1987)","journal-title":"IEEE Trans. Power Syst."},{"issue":"3","key":"44_CR21","doi-asserted-by":"publisher","first-page":"1497","DOI":"10.1109\/59.535691","volume":"11","author":"S Takriti","year":"1996","unstructured":"Takriti, S., Birge, J., Long, E.: A stochastic model for the unit commitment problem. IEEE Trans. Power Syst. 11(3), 1497\u20131508 (1996)","journal-title":"IEEE Trans. Power Syst."},{"issue":"1","key":"44_CR22","doi-asserted-by":"publisher","first-page":"411","DOI":"10.1109\/TPWRS.2005.860907","volume":"21","author":"T Ting","year":"2006","unstructured":"Ting, T., Rao, M.V.C., Loo, C.: A novel approach for unit commitment problem via an effective hybrid particle swarm optimization. IEEE Trans. Power Syst. 21(1), 411\u2013418 (2006)","journal-title":"IEEE Trans. Power Syst."},{"issue":"4","key":"44_CR23","doi-asserted-by":"publisher","first-page":"2196","DOI":"10.1109\/TPWRS.2012.2192141","volume":"27","author":"N Troy","year":"2012","unstructured":"Troy, N., Flynn, D., Milligan, M., O\u2019Malley, M.: Unit commitment with dynamic cycling costs. IEEE Trans. Power Syst. 27(4), 2196\u20132205 (2012)","journal-title":"IEEE Trans. Power Syst."},{"key":"44_CR24","doi-asserted-by":"crossref","unstructured":"Troy, N., Flynn, D., O\u2019Malley, M.: The importance of sub-hourly modeling with a high penetration of wind generation. In: 2012 IEEE Power and Energy Society General Meeting, pp. 1\u20136, July 2012","DOI":"10.1109\/PESGM.2012.6345631"},{"issue":"2","key":"44_CR25","doi-asserted-by":"publisher","first-page":"592","DOI":"10.1109\/TPWRS.2009.2016470","volume":"24","author":"A Tuohy","year":"2009","unstructured":"Tuohy, A., Meibom, P., Denny, E., O\u2019Malley, M.: Unit commitment for systems with significant wind penetration. IEEE Trans. Power Syst. 24(2), 592\u2013601 (2009)","journal-title":"IEEE Trans. Power Syst."},{"issue":"1","key":"44_CR26","doi-asserted-by":"publisher","first-page":"311","DOI":"10.1109\/59.49122","volume":"5","author":"F Zhuang","year":"1990","unstructured":"Zhuang, F., Galiana, F.: Unit commitment by simulated annealing. IEEE Trans. Power Syst. 5(1), 311\u2013318 (1990)","journal-title":"IEEE Trans. Power Syst."},{"issue":"2","key":"44_CR27","doi-asserted-by":"publisher","first-page":"763","DOI":"10.1109\/59.192933","volume":"3","author":"F Zhuang","year":"1988","unstructured":"Zhuang, F., Galiana, F.: A more rigorous and practical unit commitment by lagrangian relaxation. IEEE Trans. Power Syst. 3(2), 763\u2013773 (1988)","journal-title":"IEEE Trans. Power Syst."}],"container-title":["Lecture Notes in Computer Science","Computational Science and Its Applications \u2013 ICCSA 2017"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-319-62395-5_44","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,3,13]],"date-time":"2024-03-13T12:29:25Z","timestamp":1710332965000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/978-3-319-62395-5_44"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017]]},"ISBN":["9783319623948","9783319623955"],"references-count":27,"URL":"https:\/\/doi.org\/10.1007\/978-3-319-62395-5_44","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"value":"0302-9743","type":"print"},{"value":"1611-3349","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017]]},"assertion":[{"value":"7 July 2017","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}},{"value":"ICCSA","order":1,"name":"conference_acronym","label":"Conference Acronym","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"International Conference on Computational Science and Its Applications","order":2,"name":"conference_name","label":"Conference Name","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Trieste","order":3,"name":"conference_city","label":"Conference City","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Italy","order":4,"name":"conference_country","label":"Conference Country","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2017","order":5,"name":"conference_year","label":"Conference Year","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"3 July 2017","order":7,"name":"conference_start_date","label":"Conference Start Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"6 July 2017","order":8,"name":"conference_end_date","label":"Conference End Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"17","order":9,"name":"conference_number","label":"Conference Number","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"iccsa2017","order":10,"name":"conference_id","label":"Conference ID","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"http:\/\/www.iccsa.org\/","order":11,"name":"conference_url","label":"Conference URL","group":{"name":"ConferenceInfo","label":"Conference Information"}}]}}