{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,9,9]],"date-time":"2024-09-09T18:26:42Z","timestamp":1725906402562},"publisher-location":"Cham","reference-count":14,"publisher":"Springer International Publishing","isbn-type":[{"type":"print","value":"9783319644738"},{"type":"electronic","value":"9783319644745"}],"license":[{"start":{"date-parts":[[2017,7,29]],"date-time":"2017-07-29T00:00:00Z","timestamp":1501286400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018]]},"DOI":"10.1007\/978-3-319-64474-5_9","type":"book-chapter","created":{"date-parts":[[2017,7,28]],"date-time":"2017-07-28T14:30:11Z","timestamp":1501252211000},"page":"106-118","source":"Crossref","is-referenced-by-count":0,"title":["Sensors of Single Faults - Remarks on Measurements in Diagnosis of Industrial Processes"],"prefix":"10.1007","author":[{"given":"Jan Maciej","family":"Ko\u015bcielny","sequence":"first","affiliation":[]},{"given":"Anna","family":"Sztyber","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2017,7,29]]},"reference":[{"key":"9_CR1","unstructured":"Moore 345 XTC critical transmitter (2014), https:\/\/www.industry.usa.siemens.com\/automation\/us\/en\/process-instrumentation-and-analytics\/process-instrumentation\/service-and-support\/discontinued-product-reference\/Documents\/345xtc.pdf"},{"key":"9_CR2","unstructured":"Process Safety Beacon (2014), http:\/\/sache.org\/beacon\/files\/2009\/09\/en\/read\/2009-09-Beacon-s.pdf"},{"issue":"4\u20135","key":"9_CR3","doi-asserted-by":"publisher","first-page":"1067","DOI":"10.1016\/j.compchemeng.2007.06.020","volume":"32","author":"M Bhushan","year":"2008","unstructured":"Bhushan, M., Narasimhan, S., Rengaswamyb, R.: Robust sensor network design for fault diagnosis. Comput. Chem. Eng. 32(4\u20135), 1067\u20131084 (2008). doi: 10.1016\/j.compchemeng.2007.06.020","journal-title":"Comput. Chem. Eng."},{"key":"9_CR4","doi-asserted-by":"crossref","DOI":"10.1007\/978-1-4615-5149-2","volume-title":"Robust Model Based Fault Diagnosis for Dynamic Systems","author":"J Chen","year":"1999","unstructured":"Chen, J., Patton, R.: Robust Model Based Fault Diagnosis for Dynamic Systems. Kluver Academic Publishers, Boston (1999)"},{"key":"9_CR5","unstructured":"Frisk, E., Krysander, M.: Sensor placement for maximum fault isolability (2007). doi:10.1.1.140.9410"},{"key":"9_CR6","volume-title":"Fault Detection and Diagnosis in Engineering Systems","author":"J Gertler","year":"1998","unstructured":"Gertler, J.: Fault Detection and Diagnosis in Engineering Systems. CRC Press, Boca Raton (1998)"},{"key":"9_CR7","doi-asserted-by":"crossref","unstructured":"Korbicz, J., Ko\u015bcielny, J., Kowalczuk, Z., Cholewa, W. (eds.): Fault Diagnosis. Models, Artificial Intelligence, Applications. Springer, Heidelberg (2004)","DOI":"10.1007\/978-3-642-18615-8"},{"key":"9_CR8","doi-asserted-by":"crossref","unstructured":"Ko\u015bcielny, J.M., Syfert, M.: Current diagnostics of power boiler system with use of fuzzy logic. In: IFAC Safeprocess, pp. 681\u2013686 (2000)","DOI":"10.1016\/S1474-6670(17)37437-2"},{"key":"9_CR9","doi-asserted-by":"publisher","unstructured":"Ko\u015bscielny, J.M., Syfert, M., Rostek, K., Sztyber, A.: Fault isolability with different forms of the faults-symptoms relation. Int. J. Appl. Math. Comput. Sci. 26(4), 815\u2013826 (2016). doi: 10.1515\/amcs-2016-0058 , https:\/\/doi.org\/10.1515\/amcs-2016-0058","DOI":"10.1515\/amcs-2016-0058"},{"key":"9_CR10","doi-asserted-by":"crossref","DOI":"10.1007\/978-1-4471-3644-6","volume-title":"Issues of Fault Diagnosis for Dynamic Systems","author":"RJ Patton","year":"2000","unstructured":"Patton, R.J., Frank, P.M., Clark, R.N.: Issues of Fault Diagnosis for Dynamic Systems. Springer, Berlin (2000)"},{"key":"9_CR11","doi-asserted-by":"publisher","unstructured":"Rosich, A.: Sensor placement for fault detection and isolation based on structural models. In: IFAC Safeprocess, pp. 391\u2013396 (2012). doi: 10.3182\/20090630-4-ES-2003.00067","DOI":"10.3182\/20090630-4-ES-2003.00067"},{"issue":"1","key":"9_CR12","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1515\/amcs-2015-0002","volume":"25","author":"C Seren","year":"2015","unstructured":"Seren, C., Ezerzere, P., Hardier, G.: Model-based techniques for virtual sensing of longitudinal flight parameters. Int. J. Appl. Math. Comput. Sci. 25(1), 23\u201338 (2015)","journal-title":"Int. J. Appl. Math. Comput. Sci."},{"key":"9_CR13","doi-asserted-by":"publisher","unstructured":"Syfert, M., Ko\u015bcielny, J.M.: Diagnostic reasoning based on symptom forming sequence. In: 7th IFAC Symposium on Fault Detection, Supervision and Safety of Technical Processes, pp. 89\u201394 (2009). doi: 10.3182\/20090630-4-ES-2003.00015","DOI":"10.3182\/20090630-4-ES-2003.00015"},{"key":"9_CR14","doi-asserted-by":"crossref","unstructured":"Sztyber, A.: Sensor placement for fault diagnosis using graph of a process. J. Phys.: Conf. Ser. 783 (2017)","DOI":"10.1088\/1742-6596\/783\/1\/012007"}],"container-title":["Advances in Intelligent Systems and Computing","Advanced Solutions in Diagnostics and Fault Tolerant Control"],"original-title":[],"link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-319-64474-5_9","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,10,1]],"date-time":"2019-10-01T19:32:19Z","timestamp":1569958339000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-319-64474-5_9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,7,29]]},"ISBN":["9783319644738","9783319644745"],"references-count":14,"URL":"https:\/\/doi.org\/10.1007\/978-3-319-64474-5_9","relation":{},"ISSN":["2194-5357","2194-5365"],"issn-type":[{"type":"print","value":"2194-5357"},{"type":"electronic","value":"2194-5365"}],"subject":[],"published":{"date-parts":[[2017,7,29]]}}}