{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,25]],"date-time":"2026-02-25T08:56:22Z","timestamp":1772009782830,"version":"3.50.1"},"publisher-location":"Cham","reference-count":9,"publisher":"Springer International Publishing","isbn-type":[{"value":"9783319661780","type":"print"},{"value":"9783319661797","type":"electronic"}],"license":[{"start":{"date-parts":[[2017,1,1]],"date-time":"2017-01-01T00:00:00Z","timestamp":1483228800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2017,1,1]],"date-time":"2017-01-01T00:00:00Z","timestamp":1483228800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2017]]},"DOI":"10.1007\/978-3-319-66179-7_53","type":"book-chapter","created":{"date-parts":[[2017,9,3]],"date-time":"2017-09-03T19:24:46Z","timestamp":1504466686000},"page":"462-470","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":17,"title":["Quantification of Metabolites in Magnetic Resonance Spectroscopic Imaging Using Machine Learning"],"prefix":"10.1007","author":[{"given":"Dhritiman","family":"Das","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eduardo","family":"Coello","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rolf F.","family":"Schulte","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bjoern H.","family":"Menze","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2017,9,4]]},"reference":[{"key":"53_CR1","doi-asserted-by":"crossref","unstructured":"Pedrosa de Barros, N., McKinley, R., Wiest, R., Slotboom, J.: Improving labeling efficiency in automatic quality control of MRSI data. Magnetic Resonance in Medicine (2017). http:\/\/dx.doi.org\/10.1002\/mrm.26618","DOI":"10.1002\/mrm.26618"},{"issue":"1","key":"53_CR2","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1023\/A:1010933404324","volume":"45","author":"L Breiman","year":"2001","unstructured":"Breiman, L.: Random forests. Mach. Learn. 45(1), 5\u201332 (2001). http:\/\/dx.doi.org\/10.1023\/A:1010933404324","journal-title":"Mach. Learn."},{"issue":"1","key":"53_CR3","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1002\/nbm.1704","volume":"25","author":"BM Kelm","year":"2012","unstructured":"Kelm, B.M., Kaster, F.O., Henning, A., Weber, M.A., Bachert, P., Boesiger, P., Hamprecht, F.A., Menze, B.H.: Using spatial prior knowledge in the spectral fitting of MRS images. NMR Biomed. 25(1), 1\u201313 (2012)","journal-title":"NMR Biomed."},{"issue":"6","key":"53_CR4","doi-asserted-by":"publisher","first-page":"1457","DOI":"10.1002\/mrm.21519","volume":"59","author":"BH Menze","year":"2008","unstructured":"Menze, B.H., Kelm, B.M., Weber, M.A., Bachert, P., Hamprecht, F.A.: Mimicking the human expert: pattern recognition for an automated assessment of data quality in MR spectroscopic images. Magn. Reson. Med. 59(6), 1457\u20131466 (2008). http:\/\/dx.doi.org\/10.1002\/mrm.21519","journal-title":"Magn. Reson. Med."},{"key":"53_CR5","doi-asserted-by":"publisher","first-page":"672","DOI":"10.1002\/mrm.1910300604","volume":"6","author":"SW Provencher","year":"1993","unstructured":"Provencher, S.W.: Estimation of metabolite concentrations from localized in vivo proton NMR spectra. Magn. Reson. Med. 6, 672\u2013679 (1993)","journal-title":"Magn. Reson. Med."},{"key":"53_CR6","volume-title":"In Vivo NMR Spectroscopy: Principles and Techniques","author":"RA de Graaf","year":"2013","unstructured":"de Graaf, R.A.: In Vivo NMR Spectroscopy: Principles and Techniques, 2nd edn. Wiley, Chichester (2013)","edition":"2"},{"issue":"2","key":"53_CR7","doi-asserted-by":"publisher","first-page":"264","DOI":"10.1002\/nbm.1027","volume":"19","author":"RF Schulte","year":"2006","unstructured":"Schulte, R.F., Lange, T., Beck, J., Meier, D., Boesiger, P.: Improved two-dimensional J-resolved spectroscopy. NMR Biomed. 19(2), 264\u2013270 (2006)","journal-title":"NMR Biomed."},{"issue":"1","key":"53_CR8","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1006\/jmre.1997.1244","volume":"129","author":"L Vanhamme","year":"1997","unstructured":"Vanhamme, L., van den Boogaart, A., Huffel, S.V.: Improved method for accurate and efficient quantification of MRS data with use of prior knowledge. J. Magn. Reson. 129(1), 35\u201343 (1997). http:\/\/www.sciencedirect.com\/science\/article\/pii\/S1090780797912441","journal-title":"J. Magn. Reson."},{"issue":"1","key":"53_CR9","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1002\/mrm.22579","volume":"65","author":"M Wilson","year":"2011","unstructured":"Wilson, M., Reynolds, G., Kauppinen, R.A., Arvanitis, T.N., Peet, A.C.: A constrained least squares approach to the automated quantitation of in vivo 1h magnetic resonance spectroscopy data. Magn. Reson. Med. 65(1), 1\u201312 (2011). https:\/\/dx.doi.org\/10.1002\/mrm.22579","journal-title":"Magn. Reson. Med."}],"container-title":["Lecture Notes in Computer Science","Medical Image Computing and Computer Assisted Intervention \u2212 MICCAI 2017"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-319-66179-7_53","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,9,5]],"date-time":"2022-09-05T00:13:55Z","timestamp":1662336835000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/978-3-319-66179-7_53"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017]]},"ISBN":["9783319661780","9783319661797"],"references-count":9,"URL":"https:\/\/doi.org\/10.1007\/978-3-319-66179-7_53","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"value":"0302-9743","type":"print"},{"value":"1611-3349","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017]]},"assertion":[{"value":"4 September 2017","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}},{"value":"MICCAI","order":1,"name":"conference_acronym","label":"Conference Acronym","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"International Conference on Medical Image Computing and Computer-Assisted Intervention","order":2,"name":"conference_name","label":"Conference Name","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Quebec City, QC","order":3,"name":"conference_city","label":"Conference City","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Canada","order":4,"name":"conference_country","label":"Conference Country","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2017","order":5,"name":"conference_year","label":"Conference Year","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"10 September 2017","order":7,"name":"conference_start_date","label":"Conference Start Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"14 September 2017","order":8,"name":"conference_end_date","label":"Conference End Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"20","order":9,"name":"conference_number","label":"Conference Number","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"miccai2017","order":10,"name":"conference_id","label":"Conference ID","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"http:\/\/www.miccai2017.org\/","order":11,"name":"conference_url","label":"Conference URL","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"This content has been made available to all.","name":"free","label":"Free to read"}]}}