{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,14]],"date-time":"2025-10-14T14:40:15Z","timestamp":1760452815470,"version":"3.40.3"},"publisher-location":"Cham","reference-count":11,"publisher":"Springer International Publishing","isbn-type":[{"type":"print","value":"9783319681238"},{"type":"electronic","value":"9783319681245"}],"license":[{"start":{"date-parts":[[2017,1,1]],"date-time":"2017-01-01T00:00:00Z","timestamp":1483228800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2017]]},"DOI":"10.1007\/978-3-319-68124-5_18","type":"book-chapter","created":{"date-parts":[[2017,10,20]],"date-time":"2017-10-20T06:42:06Z","timestamp":1508481726000},"page":"204-215","source":"Crossref","is-referenced-by-count":1,"title":["Reconstruction of Sparse-View Tomography via Banded Matrices"],"prefix":"10.1007","author":[{"given":"T.","family":"Prasad","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"P. U. Praveen","family":"Kumar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C. S.","family":"Sastry","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"P. V.","family":"Jampana","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2017,10,21]]},"reference":[{"issue":"2","key":"18_CR1","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1016\/j.ejmp.2012.01.003","volume":"28","author":"M Beister","year":"2012","unstructured":"Beister, M., Kolditz, D., Kalender, W.A.: Iterative reconstruction methods in X-ray CT. Phys. Med. 28(2), 94\u2013108 (2012)","journal-title":"Phys. Med."},{"issue":"8","key":"18_CR2","doi-asserted-by":"crossref","first-page":"1537","DOI":"10.1016\/j.camwa.2016.01.003","volume":"71","author":"C Chen","year":"2016","unstructured":"Chen, C., Xu, G.: A new linearized split Bregman iterative algorithm for image reconstruction in sparse view X-ray computed tomography. Comput. Math. Appl. 71(8), 1537\u20131559 (2016)","journal-title":"Comput. Math. Appl."},{"key":"18_CR3","doi-asserted-by":"crossref","DOI":"10.1007\/978-1-4419-7011-4","volume-title":"Sparse and Redundant Representations: From Theory to Applications in Signal and Image Processing","author":"M Elad","year":"2010","unstructured":"Elad, M.: Sparse and Redundant Representations: From Theory to Applications in Signal and Image Processing. Springer, Heidelberg (2010)"},{"issue":"4","key":"18_CR4","doi-asserted-by":"crossref","first-page":"951","DOI":"10.1542\/peds.112.4.951","volume":"112","author":"DP Frush","year":"2003","unstructured":"Frush, D.P., Donnelly, L.F., Rosen, N.S.: Computed tomography and radiation risks: what pediatric health care providers should know. Pediatrics 112(4), 951\u2013957 (2003)","journal-title":"Pediatrics"},{"issue":"2","key":"18_CR5","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1137\/080725891","volume":"2","author":"T Goldstein","year":"2009","unstructured":"Goldstein, T., Osher, S.: The split Bregman method for L1-regularized problems. SIAM J. Imaging Sci. 2(2), 323\u2013343 (2009)","journal-title":"SIAM J. Imaging Sci."},{"key":"18_CR6","unstructured":"Jorgensen, J.S., Hansen, P.C., Schmidt, S.: Sparse image reconstruction in computed tomography. Technical University of Denmark, Kongens Lyngby: PHD-2013; No. 293 (2013)"},{"key":"18_CR7","doi-asserted-by":"crossref","unstructured":"Kuchment, P.: The Radon transform and medical imaging, vol. 85. SIAM (2014)","DOI":"10.1137\/1.9781611973297"},{"issue":"2","key":"18_CR8","first-page":"337","volume":"8","author":"C Jian-Feng","year":"2009","unstructured":"Jian-Feng, C., Osher, S., Shen, Z.: Split Bregman methods and frame based image restoration. SIAM J. Multiscale Model. Simul. 8(2), 337\u2013369 (2009)","journal-title":"SIAM J. Multiscale Model. Simul."},{"key":"18_CR9","doi-asserted-by":"crossref","unstructured":"Jan, J.: Medical Image Processing, Reconstruction and Restoration: Concepts and Methods, CRC Press (2005)","DOI":"10.1201\/9781420030679"},{"issue":"12","key":"18_CR10","first-page":"1230009","volume":"25","author":"XC Pan","year":"2009","unstructured":"Pan, X.C., Sidky, E.Y., Vannier, M.: Why do commercial CT scanners still employ traditional, filtered back-projection for image reconstruction? Inverse Prob. 25(12), 1230009 (2009)","journal-title":"Inverse Prob."},{"issue":"9","key":"18_CR11","doi-asserted-by":"crossref","first-page":"2367","DOI":"10.1109\/TBME.2013.2287244","volume":"61","author":"H Zhang","year":"2014","unstructured":"Zhang, H., Huang, J., Ma, J., Bian, Z., Feng, Q., Lu, H., Liang, Z., Chen, W.: Iterative reconstruction for X-Ray computed tomography using prior-image induced nonlocal regularization. IEEE Trans. Biomed. Eng. 61(9), 2367\u20132378 (2014)","journal-title":"IEEE Trans. Biomed. Eng."}],"container-title":["Lecture Notes in Computer Science","Computer Vision, Graphics, and Image Processing"],"original-title":[],"link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-319-68124-5_18","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,10,4]],"date-time":"2019-10-04T19:21:44Z","timestamp":1570216904000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-319-68124-5_18"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017]]},"ISBN":["9783319681238","9783319681245"],"references-count":11,"URL":"https:\/\/doi.org\/10.1007\/978-3-319-68124-5_18","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"type":"print","value":"0302-9743"},{"type":"electronic","value":"1611-3349"}],"subject":[],"published":{"date-parts":[[2017]]}}}