{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,3,26]],"date-time":"2025-03-26T10:27:19Z","timestamp":1742984839994,"version":"3.40.3"},"publisher-location":"Cham","reference-count":10,"publisher":"Springer International Publishing","isbn-type":[{"type":"print","value":"9783319744995"},{"type":"electronic","value":"9783319745008"}],"license":[{"start":{"date-parts":[[2018,1,1]],"date-time":"2018-01-01T00:00:00Z","timestamp":1514764800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018]]},"DOI":"10.1007\/978-3-319-74500-8_69","type":"book-chapter","created":{"date-parts":[[2018,3,20]],"date-time":"2018-03-20T00:20:32Z","timestamp":1521505232000},"page":"759-765","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Quality Control Results for Linear Accelerator at Oncology Center in Nouakchott"],"prefix":"10.1007","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1508-9872","authenticated-orcid":false,"given":"Ahmed El Mouna","family":"Ould Mohamed Yeslem","sequence":"first","affiliation":[]},{"given":"Moussa","family":"Ould Cheibetta","sequence":"additional","affiliation":[]},{"given":"Jilali","family":"Ghassoun","sequence":"additional","affiliation":[]},{"given":"Oum Keltoum","family":"Hakam","sequence":"additional","affiliation":[]},{"given":"Slimane","family":"Semghouli","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0626-3982","authenticated-orcid":false,"given":"Abdelmajid","family":"Choukri","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2018,3,21]]},"reference":[{"key":"69_CR1","unstructured":"Roy, M.L.: Study of national dosimetric standards for external beam radiotherapy: application to conformal irradiations. University of Nice Sophia-Antipolis (2012)"},{"key":"69_CR2","unstructured":"Blazy-Aubignac, L.: Quality control of the treatment planning systems dose calculations in external radiation therapy using the penelope Monte-Carlo code. University of Toulouse III \u2013 Paul Sabatier (2007)"},{"key":"69_CR3","unstructured":"Rosenwald, J.C., Bonvalet, L., Mazurier, J., M\u00e9tayer, C.: Recommandations pour la mise en service et l\u2019utilisation d\u2019un syst\u00e8me de planification de traitement en radioth\u00e9rapie (TPS), RAPPORT SFPM N\u00b0 27 (2010)"},{"key":"69_CR4","doi-asserted-by":"crossref","first-page":"1025","DOI":"10.1088\/0031-9155\/47\/7\/303","volume":"47","author":"GX Ding","year":"2002","unstructured":"Ding, G.X.: Energy spectra, angular spread, fluence profiles and dose distributions of 6 and 18 MV photon beams: results of Monte Carlo simulations for a Varian 2100EX accelerator. Phys. Med. Biol. 47, 1025\u20131046 (2002)","journal-title":"Phys. Med. Biol."},{"key":"69_CR5","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1118\/1.595908","volume":"13","author":"JA Purdy","year":"1986","unstructured":"Purdy, J.A.: Buildup\/surface dose and exit dose measurements for 6 MV linear accelerator. Med. Phys. 13, 259\u2013262 (1986)","journal-title":"Med. Phys."},{"key":"69_CR6","doi-asserted-by":"crossref","first-page":"822","DOI":"10.1118\/1.595570","volume":"11","author":"MJ Engler","year":"1984","unstructured":"Engler, M.J., Jones, G.L.: Small beam calibration by 0.6 and 0.2 cm3 ionization chambers. Med. Phys. 11, 822\u2013826 (1984)","journal-title":"Med. Phys."},{"key":"69_CR7","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1016\/j.canrad.2010.03.002","volume":"14","author":"N Villani","year":"2010","unstructured":"Villani, N., G\u00e9rard, K., Marchesi, V., Huger, S., Fran\u00e7ois, P., No\u00ebl, A.: Statistical process control applied to intensity modulated radiotherapy pretreatment controls with portal dosimetry. Cancer\/Radioth\u00e9rapie 14, 189\u2013197 (2010)","journal-title":"Cancer\/Radioth\u00e9rapie"},{"key":"69_CR8","doi-asserted-by":"crossref","first-page":"716","DOI":"10.1118\/1.594831","volume":"7","author":"CW Coffey II","year":"1980","unstructured":"Coffey II, C.W., Beach, J.L., Thompson, D.J., Mendiondo, M.: Xray beam characteristics of the Varian Clinac 6100 linear accelerator. Med. Phys. 7, 716\u2013722 (1980)","journal-title":"Med. Phys."},{"key":"69_CR9","doi-asserted-by":"crossref","first-page":"2143","DOI":"10.1088\/0031-9155\/44\/9\/303","volume":"44","author":"C McKerracher","year":"1999","unstructured":"McKerracher, C., Thwaites, D.I.: Assessment of new small-field detectors against standard-field detectors for practical stereotactic beam data acquisition. Phys. Med. Biol. 44, 2143\u20132160 (1999)","journal-title":"Phys. Med. Biol."},{"key":"69_CR10","doi-asserted-by":"crossref","first-page":"764","DOI":"10.1118\/1.595661","volume":"12","author":"G Krithivas","year":"1985","unstructured":"Krithivas, G., Rao, S.N.: A study of the characteristics of radiation contaminants within a clinically useful photon beam. Med. Phys. 12, 764\u2013768 (1985)","journal-title":"Med. Phys."}],"container-title":["Lecture Notes in Networks and Systems","Innovations in Smart Cities and Applications"],"original-title":[],"link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-319-74500-8_69","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2018,3,20]],"date-time":"2018-03-20T16:16:45Z","timestamp":1521562605000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-319-74500-8_69"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018]]},"ISBN":["9783319744995","9783319745008"],"references-count":10,"URL":"https:\/\/doi.org\/10.1007\/978-3-319-74500-8_69","relation":{},"ISSN":["2367-3370","2367-3389"],"issn-type":[{"type":"print","value":"2367-3370"},{"type":"electronic","value":"2367-3389"}],"subject":[],"published":{"date-parts":[[2018]]}}}