{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,9,10]],"date-time":"2024-09-10T12:10:24Z","timestamp":1725970224798},"publisher-location":"Cham","reference-count":16,"publisher":"Springer International Publishing","isbn-type":[{"type":"print","value":"9783319771786"},{"type":"electronic","value":"9783319771793"}],"license":[{"start":{"date-parts":[[2018,1,1]],"date-time":"2018-01-01T00:00:00Z","timestamp":1514764800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018]]},"DOI":"10.1007\/978-3-319-77179-3_8","type":"book-chapter","created":{"date-parts":[[2018,3,7]],"date-time":"2018-03-07T08:22:46Z","timestamp":1520410966000},"page":"82-92","update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Use of Electrooculography (EOG) and Facial Expressions as Part of the Brain-Computer Interface (BCI) for Controlling an Electric DC Motor"],"prefix":"10.1007","author":[{"given":"Arkadiusz","family":"Kubacki","sequence":"first","affiliation":[]},{"given":"Piotr","family":"Owczarek","sequence":"additional","affiliation":[]},{"given":"Tymoteusz","family":"Lindner","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2018,3,8]]},"reference":[{"key":"8_CR1","doi-asserted-by":"crossref","unstructured":"Hennessey, C., Fiset, J.: Long range eye tracking: bringing eye tracking into the living room. In: Proceedings of the Symposium on Eye Tracking Research and Applications, New York, NY, USA, pp. 249\u2013252 (2012)","DOI":"10.1145\/2168556.2168608"},{"key":"8_CR2","doi-asserted-by":"crossref","unstructured":"Arief, Z., Sulistijono, I.A., Ardiansyah, R.A.: Comparison of five time series EMG features extractions using Myo Armband. In: 2015 International Electronics Symposium (IES), pp. 11\u201314 (2015)","DOI":"10.1109\/ELECSYM.2015.7380805"},{"key":"8_CR3","doi-asserted-by":"crossref","unstructured":"Kubacki, A., Jakubowski, A., Sawicki, L.: Detection of artefacts from the motion of the eyelids created during EEG research using artificial neural network. In: Advances in Intelligent Systems and Computing, vol. 440, pp. 267\u2013275 (2016)","DOI":"10.1007\/978-3-319-29357-8_24"},{"issue":"6","key":"8_CR4","doi-asserted-by":"crossref","first-page":"767","DOI":"10.1016\/S1388-2457(02)00057-3","volume":"113","author":"JR Wolpaw","year":"2002","unstructured":"Wolpaw, J.R., Birbaumer, N., McFarland, D.J., Pfurtscheller, G., Vaughan, T.M.: Brain\u2013computer interfaces for communication and control. Clini. Neurophysiol. 113(6), 767\u2013791 (2002)","journal-title":"Clini. Neurophysiol."},{"issue":"3","key":"8_CR5","doi-asserted-by":"crossref","first-page":"959","DOI":"10.1109\/TITS.2013.2291402","volume":"15","author":"L Bi","year":"2014","unstructured":"Bi, L., Fan, X.A., Jie, K., Teng, T., Ding, H., Liu, Y.: Using a head-up display-based steady-state visually evoked potential brain-computer interface to control a simulated vehicle. IEEE Trans. Intell. Trans. Syst. 15(3), 959\u2013966 (2014)","journal-title":"IEEE Trans. Intell. Trans. Syst."},{"issue":"3","key":"8_CR6","doi-asserted-by":"crossref","first-page":"031012","DOI":"10.1115\/1.4002138","volume":"1","author":"VK Varadan","year":"2010","unstructured":"Varadan, V.K., Oh, S., Kwon, H., Hankins, P.: Wireless point-of-care diagnosis for sleep disorder with dry nanowire electrodes. J. Nanotechnol. Eng. Med. 1(3), 031012 (2010)","journal-title":"J. Nanotechnol. Eng. Med."},{"key":"8_CR7","doi-asserted-by":"crossref","unstructured":"O\u2019Regan, S., Faul, S., Marnane, W.: Automatic detection of EEG artefacts arising from head movements. In: 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), pp. 6353\u20136356 (2010)","DOI":"10.1109\/IEMBS.2010.5627282"},{"key":"8_CR8","first-page":"70","volume-title":"Eye Tracking Methodology Theory and Practice","author":"A Duchowski","year":"2007","unstructured":"Duchowski, A.: Eye Tracking Methodology Theory and Practice, pp. 70\u201374. Springer, London (2007)"},{"issue":"1","key":"8_CR9","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1109\/TAFFC.2015.2436926","volume":"7","author":"M Soleymani","year":"2016","unstructured":"Soleymani, M., Asghari-Esfeden, S., Fu, Y., Pantic, M.: Analysis of EEG signals and facial expressions for continuous emotion detection. IEEE Trans. Affect. Comput. 7(1), 17\u201328 (2016)","journal-title":"IEEE Trans. Affect. Comput."},{"key":"8_CR10","doi-asserted-by":"crossref","unstructured":"Gupta, S.S., Soman, S., Raj, P.G., Prakash, R., Sailaja, S., Borgohain, R.: Detecting eye movements in EEG for controlling devices. In: 2012 IEEE International Conference on Computational Intelligence and Cybernetics (CyberneticsCom), pp. 69\u201373 (2012)","DOI":"10.1109\/CyberneticsCom.2012.6381619"},{"key":"8_CR11","doi-asserted-by":"crossref","unstructured":"Champaty, B., Jose, J., Pal, K., Thirugnanam, A.: Development of EOG based human machine interface control system for motorized wheelchair. In: 2014 Annual International Conference on Emerging Research Areas: Magnetics, Machines and Drives (AICERA\/iCMMD), pp. 1\u20137 (2014)","DOI":"10.1109\/AICERA.2014.6908256"},{"issue":"14","key":"8_CR12","first-page":"2196","volume":"7","author":"S Aungsakun","year":"2012","unstructured":"Aungsakun, S., Phinyomark, A., Phukpattaranont, P., Limsakul, C.: Development of robust electrooculography (EOG)-based human-computer interface controlled by eight-directional eye movements. IJPS 7(14), 2196\u20132208 (2012)","journal-title":"IJPS"},{"key":"8_CR13","doi-asserted-by":"crossref","unstructured":"English, E., Hung, A., Kesten, E., Latulipe, D., Jin, Z.: EyePhone: a mobile EOG-based human-computer interface for assistive healthcare. In: 2013 6th International IEEE\/EMBS Conference on Neural Engineering (NER), pp. 105\u2013108 (2013)","DOI":"10.1109\/NER.2013.6695882"},{"issue":"2","key":"8_CR14","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1109\/TNSRE.2014.2365834","volume":"23","author":"M Kim","year":"2015","unstructured":"Kim, M., Kim, B.H., Jo, S.: Quantitative evaluation of a low-cost noninvasive hybrid interface based on EEG and eye movement. IEEE Trans. Neural Syst. Rehabil. Eng. 23(2), 159\u2013168 (2015)","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"8_CR15","unstructured":"Emotiv EPOC+ Specification. http:\/\/emotiv.com\/"},{"key":"8_CR16","unstructured":"Mathematical Modeling of Engineering Systems. http:\/\/www.profjrwhite.com\/system_dynamics\/sdyn\/s6\/s6fmathm\/s6fmathm.html"}],"container-title":["Advances in Intelligent Systems and Computing","Automation 2018"],"original-title":[],"link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-319-77179-3_8","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,10,12]],"date-time":"2019-10-12T09:42:05Z","timestamp":1570873325000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-319-77179-3_8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018]]},"ISBN":["9783319771786","9783319771793"],"references-count":16,"URL":"https:\/\/doi.org\/10.1007\/978-3-319-77179-3_8","relation":{},"ISSN":["2194-5357","2194-5365"],"issn-type":[{"type":"print","value":"2194-5357"},{"type":"electronic","value":"2194-5365"}],"subject":[],"published":{"date-parts":[[2018]]}}}