{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,7,5]],"date-time":"2025-07-05T04:13:45Z","timestamp":1751688825061,"version":"3.41.0"},"publisher-location":"Cham","reference-count":19,"publisher":"Springer International Publishing","isbn-type":[{"type":"print","value":"9783319912103"},{"type":"electronic","value":"9783319912110"}],"license":[{"start":{"date-parts":[[2018,6,6]],"date-time":"2018-06-06T00:00:00Z","timestamp":1528243200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019]]},"DOI":"10.1007\/978-3-319-91211-0_28","type":"book-chapter","created":{"date-parts":[[2018,6,5]],"date-time":"2018-06-05T08:59:02Z","timestamp":1528189142000},"page":"315-324","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Spatio-Temporal Extension of Independent Component Analysis for Fetal ECG Extraction"],"prefix":"10.1007","author":[{"given":"Micha\u0142","family":"Piela","sequence":"first","affiliation":[]},{"given":"Tomasz","family":"Moro\u0144","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2018,6,6]]},"reference":[{"issue":"8","key":"28_CR1","doi-asserted-by":"publisher","first-page":"1723","DOI":"10.1088\/0967-3334\/35\/8\/1723","volume":"35","author":"R Almeida","year":"2014","unstructured":"Almeida, R., Gon\u00e7alves, H., Bernardes, J., Rocha, A.P.: Fetal QRS detection and heart rate estimation: a wavelet-based approach. Physiol. Measur. 35(8), 1723 (2014)","journal-title":"Physiol. Measur."},{"key":"28_CR2","unstructured":"Behar, J., Oster, J., Clifford, G.D.: Non-invasive fECG extraction from a set of abdominal sensors. In: Computing in Cardiology Conference (CinC), pp. 297\u2013300. IEEE (2013)"},{"key":"28_CR3","doi-asserted-by":"crossref","unstructured":"Cardoso, J.F.: Multidimensional independent component analysis. In: 1998 Proceedings of the 1998 IEEE International Conference on Acoustics, Speech and Signal Processing, vol. 4, pp. 1941\u20131944. IEEE (1998)","DOI":"10.1109\/ICASSP.1998.681443"},{"issue":"5","key":"28_CR4","doi-asserted-by":"publisher","first-page":"567","DOI":"10.1109\/10.841326","volume":"47","author":"L Lathauwer De","year":"2000","unstructured":"De Lathauwer, L., De Moor, B., Vandewalle, J.: Fetal electrocardiogram extraction by blind source subspace separation. IEEE Trans. Biomed. Eng. 47(5), 567\u2013572 (2000)","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"28_CR5","doi-asserted-by":"crossref","unstructured":"De\u00a0Lathauwer, L., De\u00a0Moor, B., Vandewalle, J.: SVD-based methodologies for fetal electrocardiogram extraction. In: 2000 IEEE International Conference on Acoustics, Speech, and Signal Processing, ICASSP 2000, Proceedings, vol. 6, pp. 3771\u20133774. IEEE (2000)","DOI":"10.1109\/ICASSP.2000.860223"},{"issue":"5","key":"28_CR6","first-page":"383","volume":"57","author":"J Jezewski","year":"2012","unstructured":"Jezewski, J., Matonia, A., Kupka, T., Roj, D., Czabanski, R.: Determination of fetal heart rate from abdominal signals: evaluation of beat-to-beat accuracy in relation to the direct fetal electrocardiogram. Biomed. Tech.\/Biomed. Eng. 57(5), 383\u2013394 (2012)","journal-title":"Biomed. Tech.\/Biomed. Eng."},{"key":"28_CR7","doi-asserted-by":"crossref","unstructured":"Jezewski, J., Wrobel, J., Matonia, A., Horoba, K., Martinek, R., Kupka, T., Jezewski, M.: Is abdominal fetal electrocardiography an alternative to Doppler ultrasound for FHR variability evaluation? Front. Physiol. 8 (2017)","DOI":"10.3389\/fphys.2017.00305"},{"key":"28_CR8","unstructured":"Kotas, M.: Projective filtering of time-aligned beats for foetal ECG extraction. Tech. Sci. 55(4) (2007)"},{"issue":"1","key":"28_CR9","first-page":"75","volume":"28","author":"M Kotas","year":"2008","unstructured":"Kotas, M.: Combined application of independent component analysis and projective filtering to fetal ECG extraction. Biocybernetics Biomed. Eng. 28(1), 75 (2008)","journal-title":"Biocybernetics Biomed. Eng."},{"key":"28_CR10","first-page":"10","volume":"5","author":"M Kotas","year":"2015","unstructured":"Kotas, M., Blaszczyk, J., Moron, T.: Spatio-temporal FIR filter for fetal ECG extraction. Int. J. Inf. Electron. Eng. 5, 10\u201314 (2015)","journal-title":"Int. J. Inf. Electron. Eng."},{"issue":"1","key":"28_CR11","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1016\/j.compbiomed.2007.08.002","volume":"38","author":"M Kotas","year":"2008","unstructured":"Kotas, M.: Projective filtering of time warped ECG beats. Comput. Biol. Med. 38(1), 127\u2013137 (2008)","journal-title":"Comput. Biol. Med."},{"issue":"1","key":"28_CR12","first-page":"91","volume":"64","author":"M Kotas","year":"2016","unstructured":"Kotas, M., Leski, J., Wrobel, J.: Sequential separation of twin pregnancy electrocardiograms. Bull. Pol. Acad. Sci. Tech. Sci. 64(1), 91\u2013101 (2016)","journal-title":"Bull. Pol. Acad. Sci. Tech. Sci."},{"key":"28_CR13","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1016\/j.bspc.2015.06.003","volume":"21","author":"M Kotas","year":"2015","unstructured":"Kotas, M., Pander, T., Leski, J.M.: Averaging of nonlinearly aligned signal cycles for noise suppression. Biomed. Sig. Process. Control 21, 157\u2013168 (2015)","journal-title":"Biomed. Sig. Process. Control"},{"issue":"8","key":"28_CR14","doi-asserted-by":"publisher","first-page":"796","DOI":"10.1109\/TBME.2002.800757","volume":"49","author":"JM Leski","year":"2002","unstructured":"Leski, J.M.: Robust weighted averaging of biomedical signals. IEEE Trans. Biomed. Eng. 49(8), 796\u2013804 (2002)","journal-title":"IEEE Trans. Biomed. Eng."},{"issue":"4","key":"28_CR15","doi-asserted-by":"publisher","first-page":"373","DOI":"10.1088\/0967-3334\/28\/4\/004","volume":"28","author":"SM Martens","year":"2007","unstructured":"Martens, S.M., Rabotti, C., Mischi, M., Sluijter, R.J.: A robust fetal ECG detection method for abdominal recordings. Physiol. Meas. 28(4), 373 (2007)","journal-title":"Physiol. Meas."},{"issue":"5","key":"28_CR16","doi-asserted-by":"publisher","first-page":"1154","DOI":"10.3390\/s17051154","volume":"17","author":"R Martinek","year":"2017","unstructured":"Martinek, R., Kahankova, R., Nazeran, H., Konecny, J., Jezewski, J., Janku, P., Bilik, P., Zidek, J., Nedoma, J., Fajkus, M.: Non-invasive fetal monitoring: a maternal surface ECG electrode placement-based novel approach for optimization of adaptive filter control parameters using the LMS and RLS algorithms. Sensors 17(5), 1154 (2017)","journal-title":"Sensors"},{"key":"28_CR17","unstructured":"Momot, A., Momot, M., \u0141\u0119ski, J.: Bayesian and empirical Bayesian approach to weighted averaging of ECG signal. Tech. Sci. 55(4) (2007)"},{"key":"28_CR18","unstructured":"Silva, I., Behar, J., Sameni, R., Zhu, T., Oster, J., Clifford, G.D., Moody, G.B.: Noninvasive fetal ECG: the physionet\/computing. In: Cardiology Challenge 2013, pp. 149\u2013152 (2013)"},{"issue":"1","key":"28_CR19","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1109\/10.900244","volume":"48","author":"V Zarzoso","year":"2001","unstructured":"Zarzoso, V., Nandi, A.K.: Noninvasive fetal electrocardiogram extraction: blind separation versus adaptive noise cancellation. IEEE Trans. Biomed. Eng. 48(1), 12\u201318 (2001)","journal-title":"IEEE Trans. Biomed. Eng."}],"container-title":["Advances in Intelligent Systems and Computing","Information Technology in Biomedicine"],"original-title":[],"link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-319-91211-0_28","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,4]],"date-time":"2025-07-04T23:55:21Z","timestamp":1751673321000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-319-91211-0_28"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,6,6]]},"ISBN":["9783319912103","9783319912110"],"references-count":19,"URL":"https:\/\/doi.org\/10.1007\/978-3-319-91211-0_28","relation":{},"ISSN":["2194-5357","2194-5365"],"issn-type":[{"type":"print","value":"2194-5357"},{"type":"electronic","value":"2194-5365"}],"subject":[],"published":{"date-parts":[[2018,6,6]]}}}