{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,3,26]],"date-time":"2025-03-26T11:44:08Z","timestamp":1742989448476,"version":"3.40.3"},"publisher-location":"Cham","reference-count":15,"publisher":"Springer International Publishing","isbn-type":[{"type":"print","value":"9783319942100"},{"type":"electronic","value":"9783319942117"}],"license":[{"start":{"date-parts":[[2018,1,1]],"date-time":"2018-01-01T00:00:00Z","timestamp":1514764800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2018,1,1]],"date-time":"2018-01-01T00:00:00Z","timestamp":1514764800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018]]},"DOI":"10.1007\/978-3-319-94211-7_57","type":"book-chapter","created":{"date-parts":[[2018,6,29]],"date-time":"2018-06-29T07:29:59Z","timestamp":1530257399000},"page":"526-533","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Visualization Technique for Change of Edema Condition by Volume Measurement Using Depth Camera"],"prefix":"10.1007","author":[{"given":"Kenta","family":"Masui","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kaoru","family":"Kiyomitsu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Keiko","family":"Ogawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Norimichi","family":"Tsumura","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2018,6,30]]},"reference":[{"issue":"2","key":"57_CR1","doi-asserted-by":"publisher","first-page":"324","DOI":"10.1016\/j.jaad.2008.04.013","volume":"59","author":"K Katherine","year":"2008","unstructured":"Katherine, K., Fleischer, A., Yosipovitch, G.: Lower extremity lymphedema: update: pathophysiology, diagnosis, and treatment guidelines. J. Am. Acad. Dermatol. 59(2), 324\u2013331 (2008)","journal-title":"J. Am. Acad. Dermatol."},{"issue":"2","key":"57_CR2","doi-asserted-by":"crossref","first-page":"139","DOI":"10.3400\/avd.oa.21-00018","volume":"5","author":"Y Ogawa","year":"2012","unstructured":"Ogawa, Y.: Recent advances in medical treatment for lymphedema. Ann. Vasc. Dis. 5(2), 139\u2013144 (2012)","journal-title":"Ann. Vasc. Dis."},{"issue":"6","key":"57_CR3","first-page":"272","volume":"13","author":"HN Mayrovitz","year":"2000","unstructured":"Mayrovitz, H.N., Sims, N., Macdonald, J.: Assessment of limb volume by manual and automated methods in patients with limb edema or lymphedema. Adv. Skin Wound Care 13(6), 272\u2013276 (2000)","journal-title":"Adv. Skin Wound Care"},{"issue":"2","key":"57_CR4","doi-asserted-by":"publisher","first-page":"152","DOI":"10.1001\/archsurg.138.2.152","volume":"138","author":"A Tiwari","year":"2003","unstructured":"Tiwari, A., Cheng, K.S., Button, M., Myint, F., Hamilton, G.: Differential diagnosis, investigation, and current treatment of lower limb lymphedema. Arch. Surg. 138(2), 152\u2013161 (2003)","journal-title":"Arch. Surg."},{"issue":"3","key":"57_CR5","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1016\/j.physio.2012.12.004","volume":"99","author":"CW Tan","year":"2013","unstructured":"Tan, C.W., Coutts, F., Bulley, C.: Measurement of lower limb volume: agreement between the vertically oriented perometer and a tape measure method. Physiotherapy 99(3), 247\u2013251 (2013)","journal-title":"Physiotherapy"},{"issue":"1","key":"57_CR6","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1111\/j.0909-725X.2006.00129.x","volume":"12","author":"M Hirai","year":"2006","unstructured":"Hirai, M., Nukumizu, Y., Kidokoro, H., et al.: Effect of elastic compression stockings on oedema prevention in healthy controls evaluated by a three-dimensional measurement system. Skin Res. Technol. 12(1), 32\u201335 (2006)","journal-title":"Skin Res. Technol."},{"issue":"303","key":"57_CR7","first-page":"2","volume":"6","author":"N Cau","year":"2016","unstructured":"Cau, N., Corna, S., Aspesi, V., et al.: Circumferential versus hand-held laser scanner method for the evaluation of lower limb volumes in normal-weight and obese subjects. J. Novel Physiother. 6(303), 2 (2016)","journal-title":"J. Novel Physiother."},{"issue":"1","key":"57_CR8","first-page":"7","volume":"27","author":"K Kiyomitsu","year":"2017","unstructured":"Kiyomitsu, K., Kakinuma, A., Takahashi, H., Kamijo, N., Ogawa, K., Tsumura, N.: Volume measurement of the leg by using kinect fusion for quantitative evaluation of edemas. Bull. Soc. Photogr. Imaging Jpn. 27(1), 7\u201312 (2017)","journal-title":"Bull. Soc. Photogr. Imaging Jpn."},{"key":"57_CR9","unstructured":"Kinect for Windows Sensor, https:\/\/msdn.microsoft.com\/en-us\/library\/hh855355.aspx. Accessed 9 Feb 2018"},{"key":"57_CR10","doi-asserted-by":"crossref","unstructured":"Izadi, S., Kim, D., Hilliges, O., et al.: KinectFusion: real-time 3D reconstruction and interaction using a moving depth camera. In: Proceedings of the 24th Annual ACM Symposium on User Interface Software and Technology, pp. 559\u2013568. ACM (2011)","DOI":"10.1145\/2047196.2047270"},{"key":"57_CR11","doi-asserted-by":"crossref","unstructured":"Newcombe, R.A., Zadi, S.I., Hilliges, O., et al.: KinectFusion: real-time dense surface mapping and tracking. In: 10th IEEE International Symposium Mixed and Augmented Reality (ISMAR), pp. 127\u2013136. IEEE (2011)","DOI":"10.1109\/ISMAR.2011.6162880"},{"key":"57_CR12","unstructured":"Cignoni, P., Callieri, M., Corsini, M., Dellepiane, M., Ganovelli, F., Ranzuglia, G.: MeshLab: an open-source mesh processing tool. In: Sixth Eurographics Italian Chapter Conference, pp. 129\u2013136 (2008)"},{"issue":"11","key":"57_CR13","doi-asserted-by":"publisher","first-page":"2241","DOI":"10.1109\/TPAMI.2015.2513405","volume":"38","author":"J Yang","year":"2016","unstructured":"Yang, J., Li, H., et al.: Go-ICP: a globally optimal solution to 3D ICP point-set registration. IEEE Trans. Pattern Anal. Mach. Intell. 38(11), 2241\u20132254 (2016)","journal-title":"IEEE Trans. Pattern Anal. Mach. Intell."},{"key":"57_CR14","doi-asserted-by":"publisher","first-page":"699","DOI":"10.1287\/opre.14.4.699","volume":"14","author":"EL Wood","year":"1966","unstructured":"Wood, E.L., Lawler, D.E.: Branch-and-bound methods: a survey. Oper. Res. 14, 699\u2013719 (1966)","journal-title":"Oper. Res."},{"key":"57_CR15","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1080\/10867651.1997.10487468","volume":"2","author":"T M\u00f6ller","year":"1997","unstructured":"M\u00f6ller, T., Trumbore, B.: Fast, minimum storage ray-triangle intersection. J. Graph. Tools Arch. 2, 21\u201328 (1997)","journal-title":"J. Graph. Tools Arch."}],"container-title":["Lecture Notes in Computer Science","Image and Signal Processing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-319-94211-7_57","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,3,7]],"date-time":"2024-03-07T15:44:41Z","timestamp":1709826281000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/978-3-319-94211-7_57"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018]]},"ISBN":["9783319942100","9783319942117"],"references-count":15,"URL":"https:\/\/doi.org\/10.1007\/978-3-319-94211-7_57","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"type":"print","value":"0302-9743"},{"type":"electronic","value":"1611-3349"}],"subject":[],"published":{"date-parts":[[2018]]},"assertion":[{"value":"30 June 2018","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}},{"value":"ICISP","order":1,"name":"conference_acronym","label":"Conference Acronym","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"International Conference on Image and Signal Processing","order":2,"name":"conference_name","label":"Conference Name","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Cherbourg","order":3,"name":"conference_city","label":"Conference City","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"France","order":4,"name":"conference_country","label":"Conference Country","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2018","order":5,"name":"conference_year","label":"Conference Year","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2 July 2018","order":7,"name":"conference_start_date","label":"Conference Start Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"4 July 2018","order":8,"name":"conference_end_date","label":"Conference End Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"8","order":9,"name":"conference_number","label":"Conference Number","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"icisp2018","order":10,"name":"conference_id","label":"Conference ID","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"http:\/\/www.icisp-conf.org\/index.php.html","order":11,"name":"conference_url","label":"Conference URL","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Single-blind","order":1,"name":"type","label":"Type","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"EasyChair","order":2,"name":"conference_management_system","label":"Conference Management System","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"122","order":3,"name":"number_of_submissions_sent_for_review","label":"Number of Submissions Sent for Review","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"58","order":4,"name":"number_of_full_papers_accepted","label":"Number of Full Papers Accepted","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"0","order":5,"name":"number_of_short_papers_accepted","label":"Number of Short Papers Accepted","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"48% - The value is computed by the equation \"Number of Full Papers Accepted \/ Number of Submissions Sent for Review * 100\" and then rounded to a whole number.","order":6,"name":"acceptance_rate_of_full_papers","label":"Acceptance Rate of Full Papers","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"2.2","order":7,"name":"average_number_of_reviews_per_paper","label":"Average Number of Reviews per Paper","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"1.88","order":8,"name":"average_number_of_papers_per_reviewer","label":"Average Number of Papers per Reviewer","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"No","order":9,"name":"external_reviewers_involved","label":"External Reviewers Involved","group":{"name":"ConfEventPeerReviewInformation","label":"Peer Review Information (provided by the conference organizers)"}},{"value":"This content has been made available to all.","name":"free","label":"Free to read"}]}}