{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,30]],"date-time":"2025-09-30T04:35:25Z","timestamp":1759206925615},"publisher-location":"Berlin, Heidelberg","reference-count":23,"publisher":"Springer Berlin Heidelberg","isbn-type":[{"type":"print","value":"9783540204640"},{"type":"electronic","value":"9783540399032"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2003]]},"DOI":"10.1007\/978-3-540-39903-2_16","type":"book-chapter","created":{"date-parts":[[2010,9,9]],"date-time":"2010-09-09T13:49:25Z","timestamp":1284040165000},"page":"126-133","source":"Crossref","is-referenced-by-count":3,"title":["3D Reconstruction from Truncated Rotational Angiograms Using Linear Prediction"],"prefix":"10.1007","author":[{"given":"Ramesh R.","family":"Galigekere","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David W.","family":"Holdsworth","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"16_CR1","first-page":"1507","volume":"18","author":"R. Fahrig","year":"1997","unstructured":"Fahrig, R., Fox, A.J., Lownie, S., Holdsworth, D.W.: Use of a C-arm system to generate true three-dimensional computed rotational angiograms: Preliminary in vitro and in vivo results. Am. J. Neuroradiol.\u00a018, 1507\u20131514 (1997)","journal-title":"Am. J. Neuroradiol."},{"key":"16_CR2","doi-asserted-by":"publisher","first-page":"391","DOI":"10.1109\/42.870250","volume":"19","author":"K. Wiesent","year":"2000","unstructured":"Wiesent, K., Barth, K., Navab, N., Durlak, P., Brunner, T., Schuetz, O., Seissler, W.: Enhanced 3D-reconstruction algorithms for C-arm systems suitable for interventional procedures. IEEE Trans. Med. Imag.\u00a019, 391\u2013403 (2000)","journal-title":"IEEE Trans. Med. Imag."},{"key":"16_CR3","series-title":"Lecture Notes in Computer Science","doi-asserted-by":"publisher","first-page":"688","DOI":"10.1007\/10704282_75","volume-title":"Medical Image Computing and Computer-Assisted Intervention \u2013 MICCAI\u201999","author":"N. Navab","year":"1999","unstructured":"Navab, N., Mitschke, M., Schuetz, O.: Camera-augmented mobile C-arm (CAMC) applications: 3D reconstruction using a low-cost mobile C-arm. In: Taylor, C., Colchester, A. (eds.) MICCAI 1999. LNCS, vol.\u00a01679, pp. 688\u2013697. Springer, Heidelberg (1999)"},{"key":"16_CR4","doi-asserted-by":"publisher","first-page":"612","DOI":"10.1364\/JOSAA.1.000612","volume":"1","author":"L.A. Feldkamp","year":"1984","unstructured":"Feldkamp, L.A., Davis, L.C., Kress, J.W.: Practical cone-beam algorithm. J. Opt. Soc. Am. A, Opt. Image Sci.\u00a01, 612\u2013619 (1984)","journal-title":"J. Opt. Soc. Am. A, Opt. Image Sci."},{"key":"16_CR5","volume-title":"Principles of Computerized Tomographic Imaging","author":"A.C. Kak","year":"1988","unstructured":"Kak, A.C., Slaney, M.: Principles of Computerized Tomographic Imaging. IEEE Computer Society Press, Los Alamitos (1988)"},{"key":"16_CR6","unstructured":"Galigekere, R.R., Wiesent, K., Holdsworth, D.W.: On cone-beam Reprojection of a 3-D Reconstruction and its Applications. World Congress on Medical Physics and Biomedical Engineering (Med. Phy. 27, p. 1396) (August 2000)"},{"key":"16_CR7","doi-asserted-by":"crossref","unstructured":"Galigekere, R.R., Wiesent, K., Holdsworth, D.W.: Cone-beam reprojection using projection matrices. IEEE Trans. Med. Imag. (October 2003) (to appear)","DOI":"10.1109\/TMI.2003.817787"},{"key":"16_CR8","doi-asserted-by":"crossref","unstructured":"Galigekere, R.R., Holdsworth, D.W.: On Perspective Maximum Intensity Projection of CRA data. In: Proc. SPIE Symp. Medical Imaging, vol.\u00a04681, pp. 688\u2013697 (2002)","DOI":"10.1117\/12.466979"},{"key":"16_CR9","unstructured":"Galigekere, R.R., Holdsworth, D.W.: Cone-beam Maximum Intensity Projection Algorthims for Computed Rotational Angiography (to be submitted to Med. Phys.)"},{"key":"16_CR10","first-page":"19","volume":"50","author":"R.M. Lewitt","year":"1978","unstructured":"Lewitt, R.M., Bates, R.H.T.: Image reconstruction from projections: I: General theoretical considerations. Optik\u00a050, 19\u201333 (1978)","journal-title":"Optik"},{"key":"16_CR11","first-page":"189","volume":"50","author":"R.M. Lewitt","year":"1978","unstructured":"Lewitt, R.M., Bates, R.H.T.: Image reconstruction from projections: III: Projection completion methods (theory). Optik\u00a050, 189\u2013204 (1978)","journal-title":"Optik"},{"key":"16_CR12","first-page":"269","volume":"50","author":"R.M. Lewitt","year":"1978","unstructured":"Lewitt, R.M., Bates, R.H.T.: Image reconstruction from projections: IV: Projections completion methods (computational examples). Optik\u00a050, 269\u2013278 (1978)","journal-title":"Optik"},{"key":"16_CR13","doi-asserted-by":"publisher","first-page":"129","DOI":"10.1088\/0031-9155\/25\/1\/012","volume":"25","author":"J.C. Gore","year":"1980","unstructured":"Gore, J.C., Leeman, S.: The reconstruction of objects from incomplete projections. Phys. Med. Biol.\u00a025, 129\u2013136 (1980)","journal-title":"Phys. Med. Biol."},{"key":"16_CR14","doi-asserted-by":"publisher","first-page":"117","DOI":"10.1088\/0031-9155\/25\/1\/011","volume":"25","author":"P.S. Tofts","year":"1980","unstructured":"Tofts, P.S., Gore, J.C.: Some sources of artefact in computed tomography. Phys. Med. Biol.\u00a025, 117\u2013127 (1980)","journal-title":"Phys. Med. Biol."},{"key":"16_CR15","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1097\/00004728-198102000-00026","volume":"5","author":"G.T. Herman","year":"1981","unstructured":"Herman, G.T., Lewitt, R.M.: Evaluation of a preprocessing algorithm for truncated CT projections. J. Comput. Assist. Tomogr.\u00a05, 127\u2013135 (1981)","journal-title":"J. Comput. Assist. Tomogr."},{"key":"16_CR16","first-page":"183","volume":"141","author":"J.L. Lehr","year":"1983","unstructured":"Lehr, J.L.: Truncated-view artifacts: Clinical importance on CT. Am. J. Radiol.\u00a0141, 183\u2013191 (1983)","journal-title":"Am. J. Radiol."},{"key":"16_CR17","unstructured":"Srinivasa, N., Krishnan, V., Ramakrishnan, K.R., Rajgopal, K.: Image reconstruction from Truncated Projections: A Linear Prediction Approach. In: Int. Conf. Acoust. Speech Signal Process, Tokyo, pp. 34.3.1\u201334.3.4 (1988)"},{"key":"16_CR18","unstructured":"Rajgopal, K., Srinivasa, N., Ramakrishnan, K.R.: Image reconstruction from incomplete projection data: A linear prediction approach. In: Leondes, C.T. (ed.) Medical Imaging Systems, Techniques and Applications: Modalities, Gordon and Breach International Series in Engineering, Technology and Applied Science (1997)"},{"key":"16_CR19","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1118\/1.598855","volume":"27","author":"B. Ohnesorge","year":"2000","unstructured":"Ohnesorge, B., Flohr, T., Schwarz, K., Heiken, J.P., Bae, K.T.: Efficient correction for CT image artifacts caused by objects extending outside the scan field of view. Med. Phys.\u00a027, 39\u201346 (2000)","journal-title":"Med. Phys."},{"key":"16_CR20","doi-asserted-by":"publisher","first-page":"561","DOI":"10.1109\/PROC.1975.9792","volume":"63","author":"J. Makhoul","year":"1975","unstructured":"Makhoul, J.: Linear prediction: A tutorial review. Proc. IEEE\u00a063, 561\u2013580 (1975)","journal-title":"Proc. IEEE"},{"key":"16_CR21","volume-title":"Optimum Signal Processing","author":"S.J. Orfanidis","year":"1990","unstructured":"Orfanidis, S.J.: Optimum Signal Processing. McGraw-Hill International Edition, New Delhi (1990)"},{"key":"16_CR22","doi-asserted-by":"publisher","first-page":"1097","DOI":"10.1118\/1.598013","volume":"24","author":"R. Fahrig","year":"1997","unstructured":"Fahrig, R., Moreau, M., Holdsworth, D.W.: Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: Correction of image intensifier distortion. Med. Phys.\u00a024, 1097\u20131106 (1997)","journal-title":"Med. Phys."},{"key":"16_CR23","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1118\/1.598854","volume":"27","author":"R. Fahrig","year":"2000","unstructured":"Fahrig, R., Holdsworth, D.W.: Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: Image-based correction of gantry motion nonidealities. Med. Phys.\u00a027, 30\u201338 (2000)","journal-title":"Med. Phys."}],"container-title":["Lecture Notes in Computer Science","Medical Image Computing and Computer-Assisted Intervention - MICCAI 2003"],"original-title":[],"link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-540-39903-2_16","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,6,4]],"date-time":"2019-06-04T08:50:37Z","timestamp":1559638237000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-540-39903-2_16"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2003]]},"ISBN":["9783540204640","9783540399032"],"references-count":23,"URL":"https:\/\/doi.org\/10.1007\/978-3-540-39903-2_16","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"type":"print","value":"0302-9743"},{"type":"electronic","value":"1611-3349"}],"subject":[],"published":{"date-parts":[[2003]]}}}