{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,9,5]],"date-time":"2024-09-05T19:32:58Z","timestamp":1725564778056},"publisher-location":"Berlin, Heidelberg","reference-count":10,"publisher":"Springer Berlin Heidelberg","isbn-type":[{"type":"print","value":"9783540204640"},{"type":"electronic","value":"9783540399032"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2003]]},"DOI":"10.1007\/978-3-540-39903-2_17","type":"book-chapter","created":{"date-parts":[[2010,9,9]],"date-time":"2010-09-09T09:49:25Z","timestamp":1284025765000},"page":"134-141","source":"Crossref","is-referenced-by-count":4,"title":["Tomographic Reconstruction for Truncated Cone Beam Data Using Prior CT Information"],"prefix":"10.1007","author":[{"given":"Krishnakumar","family":"Ramamurthi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jerry","family":"Prince","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"17_CR1","doi-asserted-by":"publisher","first-page":"546","DOI":"10.1137\/0143035","volume":"43","author":"H.K. Tuy","year":"1983","unstructured":"Tuy, H.K.: An inversion formula for cone-beam reconstruction. SIAM Journal of Applied Mathematics\u00a043, 546\u2013552 (1983)","journal-title":"SIAM Journal of Applied Mathematics"},{"key":"17_CR2","doi-asserted-by":"publisher","first-page":"342","DOI":"10.1109\/42.158938","volume":"11","author":"J.X. Chen","year":"1992","unstructured":"Chen, J.X.: A theoretical framework of regional cone-beam tomography. IEEE Transactions on Medical Imaging\u00a011, 342\u2013350 (1992)","journal-title":"IEEE Transactions on Medical Imaging"},{"key":"17_CR3","doi-asserted-by":"crossref","unstructured":"Feldkamp, L.A., Davis, L.C., Kress, J.W.: Practical cone-beam algorithm. Optical Society of America\u00a01(6) (June 1984)","DOI":"10.1364\/JOSAA.1.000612"},{"key":"17_CR4","doi-asserted-by":"crossref","unstructured":"Kak, A.C., Slaney, M.: Principles of Computerized Tomographic Imaging. Society of Industrial and Applied Mathematics (2001)","DOI":"10.1137\/1.9780898719277"},{"key":"17_CR5","first-page":"254","volume":"9","author":"D.L. Parker","year":"1982","unstructured":"Parker, D.L.: Optimal short scan convolution reconstruction for fanbeam ct. Physics in Medicine and Biology\u00a09, 254\u2013257 (1982)","journal-title":"Physics in Medicine and Biology"},{"key":"17_CR6","doi-asserted-by":"publisher","first-page":"2525","DOI":"10.1088\/0031-9155\/47\/14\/311","volume":"47","author":"F. Noo","year":"2002","unstructured":"Noo, F., Defrise, M., Clackdoyle, R., Kudo, H.: Image reconstruction from fan-beam projections on less than a short-scan. Physics in Medicine and Biology\u00a047, 2525\u20132546 (2002)","journal-title":"Physics in Medicine and Biology"},{"key":"17_CR7","unstructured":"M\u00fcller-Merbach, J.: Manual: Simulation of X-Ray Projections For Experimental 3D Tomography (1996)"},{"issue":"5","key":"17_CR8","doi-asserted-by":"publisher","first-page":"391","DOI":"10.1109\/42.870250","volume":"19","author":"K. Wiesent","year":"2000","unstructured":"Wiesent, K., Barth, K., Navab, N., Durlak, P., Brunner, T., Schuetz, O., Seissler, W.: Enhanced 3-d-reconstruction algorithm for c-arm systems suitable for interventional procedures. IEEE Transactions on Medical Imaging (ITMI)\u00a019(5), 391\u2013403 (2000)","journal-title":"IEEE Transactions on Medical Imaging (ITMI)"},{"key":"17_CR9","series-title":"Lecture Notes in Computer Science","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1007\/BFb0056194","volume-title":"Medical Image Computing and Computer-Assisted Intervention - MICCAI\u201998","author":"N. Navab","year":"1998","unstructured":"Navab, N., Bani-Hashemi, A., Nadar, M., Wiesent, K., Durlak, P., Brunner, T., Barth, K., Graumann, R.: 3d reconstruction from projection matrices in a c-arm based 3d-angiography system. In: Wells, W.M., Colchester, A.C.F., Delp, S.L. (eds.) MICCAI 1998. LNCS, vol.\u00a01496, p. 119. Springer, Heidelberg (1998)"},{"key":"17_CR10","series-title":"Lecture Notes in Computer Science","doi-asserted-by":"publisher","first-page":"688","DOI":"10.1007\/10704282_75","volume-title":"Medical Image Computing and Computer-Assisted Intervention \u2013 MICCAI\u201999","author":"N. Navab","year":"1999","unstructured":"Navab, N., Mitschke, M., Schuetz, O.: Camera augmented mobile c-arm (camc) application: 3d reconstruction using a low-cost mobile c-arm. In: Taylor, C., Colchester, A. (eds.) MICCAI 1999. LNCS, vol.\u00a01679, pp. 688\u2013697. Springer, Heidelberg (1999)"}],"container-title":["Lecture Notes in Computer Science","Medical Image Computing and Computer-Assisted Intervention - MICCAI 2003"],"original-title":[],"link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-540-39903-2_17","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,6,4]],"date-time":"2019-06-04T04:46:53Z","timestamp":1559623613000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-540-39903-2_17"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2003]]},"ISBN":["9783540204640","9783540399032"],"references-count":10,"URL":"https:\/\/doi.org\/10.1007\/978-3-540-39903-2_17","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"type":"print","value":"0302-9743"},{"type":"electronic","value":"1611-3349"}],"subject":[],"published":{"date-parts":[[2003]]}}}