{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,6]],"date-time":"2026-03-06T07:11:35Z","timestamp":1772781095720,"version":"3.50.1"},"publisher-location":"Berlin, Heidelberg","reference-count":16,"publisher":"Springer Berlin Heidelberg","isbn-type":[{"value":"9783540411895","type":"print"},{"value":"9783540408994","type":"electronic"}],"license":[{"start":{"date-parts":[[2000,1,1]],"date-time":"2000-01-01T00:00:00Z","timestamp":946684800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2000]]},"DOI":"10.1007\/978-3-540-40899-4_95","type":"book-chapter","created":{"date-parts":[[2011,1,14]],"date-time":"2011-01-14T20:48:56Z","timestamp":1295038136000},"page":"921-930","source":"Crossref","is-referenced-by-count":77,"title":["MR Compatible Surgical Assist Robot: System Integration and Preliminary Feasibility Study"],"prefix":"10.1007","author":[{"given":"Kiyoyuki","family":"Chinzei","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nobuhiko","family":"Hata","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ferenc A.","family":"Jolesz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ron","family":"Kikinis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"95_CR1","doi-asserted-by":"crossref","unstructured":"Villotte, N., Glauser, D., Flury, P., et al.: Conception of Stereotactic Instruments for the Neurosurgical Robot Minerva. In: Proc. IEEE ICRA, pp. 1089\u20131090 (1992)","DOI":"10.1109\/IEMBS.1992.5761367"},{"key":"95_CR2","first-page":"379","volume-title":"Computer- Integrated Surgery : Technology and Clinical Applications","author":"R.H. Taylor","year":"1995","unstructured":"Taylor, R.H., Mitterlstadt, B.D., Paul, H.A., et al.: An Image-Directed Robotic System for Precise Orthopedic Surgery. In: Taylor, R.H., et al. (eds.) Computer- Integrated Surgery: Technology and Clinical Applications, pp. 379\u2013395. MIT Press, Cambridge (1995)"},{"key":"95_CR3","first-page":"577","volume-title":"Computer-Integrated Surgery : Technology and Clinical Applications","author":"J.M. Sackier","year":"1995","unstructured":"Sackier, J.M., Wang, Y.: Robotically Assisted Laparoscopic Surgery: from Concept to Development. In: Taylor, R.H., et al. (eds.) Computer-Integrated Surgery: Technology and Clinical Applications, pp. 577\u2013580. MIT Press, Cambridge (1995)"},{"key":"95_CR4","series-title":"Lecture Notes in Computer Science","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1007\/BFb0034939","volume-title":"Computer Vision, Virtual Reality and Robotics in Medicine","author":"P.S. Schenker","year":"1995","unstructured":"Schenker, P.S., Das, H., Ohm, T.R.: A New Robot for High Dexterity Microsurgery. In: Ayache, N. (ed.) CVRMed 1995. LNCS, vol.\u00a0905, pp. 115\u2013122. Springer, Heidelberg (1995)"},{"issue":"3","key":"95_CR5","doi-asserted-by":"crossref","first-page":"805","DOI":"10.1148\/radiology.195.3.7754014","volume":"195","author":"J.F. Schenck","year":"1995","unstructured":"Schenck, J.F., Jolesz, F.A., Roemer, P.B., et al.: Superconducting Open- Configuration MR Imaging System for Image-Guided Therapy. Radiology\u00a0195(3), 805\u2013814 (1995)","journal-title":"Radiology"},{"key":"95_CR6","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1148\/radiology.197.1.7568819","volume":"197","author":"S.G. Silverman","year":"1995","unstructured":"Silverman, S.G., Collick, B.D., Figueira, M.R., et al.: InteractiveMR-guided biopsy in an open-configuration MR imaging system. Radiology\u00a0197, 175\u2013181 (1995)","journal-title":"Radiology"},{"issue":"3","key":"95_CR7","doi-asserted-by":"publisher","first-page":"304","DOI":"10.1117\/1.429857","volume":"3","author":"N. Hata","year":"1998","unstructured":"Hata, N., Morrison, P.R., Kettenbach, J., Black, P., Kikinis, R., Jolesz, F.A.: Computer-assisted Intra-Operative Magnetic Resonance Imaging Monitoring of Interstitial Laser Therapy in the Brain: A Case Report. J. Biomedical. Optics\u00a03(3), 304\u2013311 (1998)","journal-title":"J. Biomedical. Optics"},{"issue":"6","key":"95_CR8","doi-asserted-by":"publisher","first-page":"815","DOI":"10.1118\/1.597854","volume":"23","author":"J.F. Schenck","year":"1996","unstructured":"Schenck, J.F.: The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds. Med. Phys.\u00a023(6), 815\u2013850 (1996)","journal-title":"Med. Phys."},{"key":"95_CR9","unstructured":"GE Medical Systems (ed.): MR Safety and MR Compatibility: Test Guidelines for Signa SP\n                    TM\n                   (1997), \n                    \n                      http:\/\/www.ge.com\/medical\/mr\/iomri\/safety.htm"},{"key":"95_CR10","doi-asserted-by":"publisher","first-page":"242","DOI":"10.1002\/(SICI)1522-712X(1995)1:4<242::AID-IGS7>3.0.CO;2-A","volume":"1","author":"K. Masamune","year":"1995","unstructured":"Masamune, K., Kobayashi, E., Masutani, Y., et al.: Development of an MRI compatible Needle Insertion Manipulator for Stereotactic Neurosurgery. J. Image Guided Surgery\u00a01, 242\u2013248 (1995)","journal-title":"J. Image Guided Surgery"},{"key":"95_CR11","series-title":"Lecture Notes in Computer Science","doi-asserted-by":"publisher","first-page":"1020","DOI":"10.1007\/10704282_111","volume-title":"Medical Image Computing and Computer-Assisted Intervention \u2013 MICCAI\u201999","author":"K. Chinzei","year":"1999","unstructured":"Chinzei, K., Kikinis, R., Jolesz, F.A.: MR Compatibility of Mechatronic Devices: Design Criteria. In: Taylor, C., Colchester, A. (eds.) MICCAI 1999. LNCS, vol.\u00a01679, pp. 1020\u20131031. Springer, Heidelberg (1999)"},{"key":"95_CR12","doi-asserted-by":"crossref","unstructured":"Schorr, O., Hata, N., Bzostek, A., Kumar, R., Burghart, C., Taylor, R.H., Kikinis, R.: Distributed Modular Computer-Integrated Surgical Robotic Systems: Architecture for Intelligent Object Distribution. In: Delp, S.L., DiGoia, A.M., Jaramaz, B. (eds.) MICCAI 2000. LNCS, vol.\u00a01935, pp. 979\u2013987. Springer, Heidelberg (2000) (printing)","DOI":"10.1007\/978-3-540-40899-4_102"},{"key":"95_CR13","series-title":"Lecture Notes in Computer Science","doi-asserted-by":"publisher","first-page":"809","DOI":"10.1007\/10704282_88","volume-title":"Medical Image Computing and Computer-Assisted Intervention \u2013 MICCAI\u201999","author":"D. Gering","year":"1999","unstructured":"Gering, D., Nabavi, A., Kikinis, R., Eric, W., Grimson, L., Hata, N., et al.: An Integrated Visualization System for Surgical Planning and Guidance using Image Fusion and Interventional Imaging. In: Taylor, C., Colchester, A. (eds.) MICCAI 1999. LNCS, vol.\u00a01679, pp. 809\u2013819. Springer, Heidelberg (1999)"},{"key":"95_CR14","doi-asserted-by":"publisher","first-page":"255","DOI":"10.1002\/mrm.1910070302","volume":"7","author":"R. Buchili","year":"1988","unstructured":"Buchili, R., Boesiger, P., Meier, D.: Heating Effects of Metallic Implants by MRI Examinations. Magnet. Reson. Med.\u00a07, 255\u2013261 (1988)","journal-title":"Magnet. Reson. Med."},{"key":"95_CR15","doi-asserted-by":"crossref","unstructured":"Koseki, Y., Chinzei, K., Koyachi, N., Arai, T.: Robotic Assist for MR-Guided Surgery Using Leverage and Palallelepiped Mechanism. In: Delp, S.L., DiGoia, A.M., Jaramaz, B. (eds.) MICCAI 2000. LNCS, vol.\u00a01935, pp. 940\u2013948. Springer, Heidelberg (2000) (printing)","DOI":"10.1007\/978-3-540-40899-4_97"},{"issue":"3","key":"95_CR16","doi-asserted-by":"publisher","first-page":"507","DOI":"10.1016\/S0360-3016(98)00271-5","volume":"42","author":"A.V. D\u2019Amico","year":"1998","unstructured":"D\u2019Amico, A.V., et al.: Real-time magnetic resonance image-guided interstitial brachytherapy in the treatment of select patients with clinically localized prostate cancer. Int. J. Radiat. Oncol. Biol. Phys.\u00a042(3), 507\u2013515 (1998)","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."}],"container-title":["Lecture Notes in Computer Science","Medical Image Computing and Computer-Assisted Intervention \u2013 MICCAI 2000"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-540-40899-4_95","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,19]],"date-time":"2019-05-19T23:43:22Z","timestamp":1558309402000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-540-40899-4_95"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2000]]},"ISBN":["9783540411895","9783540408994"],"references-count":16,"URL":"https:\/\/doi.org\/10.1007\/978-3-540-40899-4_95","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"value":"0302-9743","type":"print"},{"value":"1611-3349","type":"electronic"}],"subject":[],"published":{"date-parts":[[2000]]}}}