{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,9,5]],"date-time":"2024-09-05T00:44:03Z","timestamp":1725497043867},"publisher-location":"Berlin, Heidelberg","reference-count":16,"publisher":"Springer Berlin Heidelberg","isbn-type":[{"type":"print","value":"9783540771289"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"DOI":"10.1007\/978-3-540-77129-6_46","type":"book-chapter","created":{"date-parts":[[2007,12,6]],"date-time":"2007-12-06T15:37:36Z","timestamp":1196955456000},"page":"522-532","source":"Crossref","is-referenced-by-count":0,"title":["Motion Estimation Applied to Reconstruct Undersampled Dynamic MRI"],"prefix":"10.1007","author":[{"given":"Claudia","family":"Prieto","sequence":"first","affiliation":[]},{"given":"Marcelo","family":"Guarini","sequence":"additional","affiliation":[]},{"given":"Joseph","family":"Hajnal","sequence":"additional","affiliation":[]},{"given":"Pablo","family":"Irarrazaval","sequence":"additional","affiliation":[]}],"member":"297","reference":[{"key":"46_CR1","doi-asserted-by":"publisher","first-page":"92","DOI":"10.1002\/mrm.21267","volume":"58","author":"K.Z. Abd-Elmoniem","year":"2007","unstructured":"Abd-Elmoniem, K.Z., Osman, N.F., Prince, J.L., Stuber, M.: Three-dimensional magnetic resonance myocardial motion tracking from a single image plane. Magn. Reson. Med.\u00a058, 92\u2013102 (2007)","journal-title":"Magn. Reson. Med."},{"key":"46_CR2","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1002\/jmri.20976","volume":"26","author":"H. Sakuma","year":"2007","unstructured":"Sakuma, H.: Magnetic resonance imaging for ischemic heart disease. J. Magn. Reson. Imaging.\u00a026, 3\u201313 (2007)","journal-title":"J. Magn. Reson. Imaging."},{"key":"46_CR3","doi-asserted-by":"publisher","first-page":"196","DOI":"10.1016\/j.tcm.2007.05.003","volume":"17","author":"V.K. Raman","year":"2007","unstructured":"Raman, V.K., Lederman, R.J.: Interventional cardiovascular magnetic resonance imaging. Trends Cardiovasc. Med.\u00a017, 196\u2013202 (2007)","journal-title":"Trends Cardiovasc. Med."},{"key":"46_CR4","doi-asserted-by":"publisher","first-page":"354","DOI":"10.1097\/01.rct.0000238009.57307.26","volume":"31","author":"V. Gupta","year":"2007","unstructured":"Gupta, V., Khandelwal, N., Mathuria, S., Singh, P., Pathak, A., Suri, S.: Dynamic magnetic resonance imaging evaluation of craniovertebral junction abnormalities. J. Comput. Assist. Tomogr.\u00a031, 354\u2013359 (2007)","journal-title":"J. Comput. Assist. Tomogr."},{"key":"46_CR5","doi-asserted-by":"publisher","first-page":"422","DOI":"10.1002\/mrm.1910290324","volume":"29","author":"Q.S. Xiang","year":"1993","unstructured":"Xiang, Q.S., Henkelman, R.M.: k-space description for MR imaging of dynamic objects. Magn. Reson. Med.\u00a029, 422\u2013428 (1993)","journal-title":"Magn. Reson. Med."},{"key":"46_CR6","doi-asserted-by":"publisher","first-page":"830","DOI":"10.1002\/mrm.1910290618","volume":"29","author":"R.A. Jones","year":"1993","unstructured":"Jones, R.A., Haraldseth, O., Muller, T.B., Rinck, P.A., Oksendal, A.N.: k-space substitution: a novel dynamic imaging technique. Magn. Reson. Med.\u00a029, 830\u2013834 (1993)","journal-title":"Magn. Reson. Med."},{"key":"46_CR7","doi-asserted-by":"publisher","first-page":"671","DOI":"10.1002\/jmri.1880030419","volume":"3","author":"J.J. Vaals van","year":"1993","unstructured":"van Vaals, J.J., Brummer, M.E., Dixon, W.T., Tuithof, H.H., Engels, H., Nelson, R.C., Gerety, B.M., Chezmar, J.L., den Boer, J.A.: Keyhole method for accelerating imaging of contrast agent uptake. J. Magn. Reson. Imaging\u00a03, 671\u2013675 (1993)","journal-title":"J. Magn. Reson. Imaging"},{"key":"46_CR8","doi-asserted-by":"publisher","first-page":"691","DOI":"10.1002\/mrm.1910310618","volume":"31","author":"X. Hu","year":"1994","unstructured":"Hu, X., Parrish, T.: Reduction of field of view for dynamic imaging. Magn. Reson. Med.\u00a031, 691\u2013694 (1994)","journal-title":"Magn. Reson. Med."},{"key":"46_CR9","doi-asserted-by":"publisher","first-page":"813","DOI":"10.1002\/(SICI)1522-2594(199911)42:5<813::AID-MRM1>3.0.CO;2-S","volume":"42","author":"B. Madore","year":"1999","unstructured":"Madore, B., Glover, G.H., Pelc, N.J.: Unaliasing by Fourier-encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRI. Magn. Reson. Med.\u00a042, 813\u2013828 (1999)","journal-title":"Magn. Reson. Med."},{"key":"46_CR10","doi-asserted-by":"publisher","first-page":"1031","DOI":"10.1002\/mrm.10611","volume":"50","author":"J. Tsao","year":"2003","unstructured":"Tsao, J., Boesinger, P., Pruessmann, K.P.: k-t BLAST and k-t SENSE: dynamic MRI with high frame rate exploiting spatiotemporal correlations. Magn. Reson. Med.\u00a050, 1031\u20131042 (2003)","journal-title":"Magn. Reson. Med."},{"key":"46_CR11","doi-asserted-by":"publisher","first-page":"1207","DOI":"10.1002\/mrm.20671","volume":"54","author":"P. Irarrazaval","year":"2005","unstructured":"Irarrazaval, P., Bourbetakh, R., Razavi, R., Hill, D.: Dynamic three-dimensional undersampled data reconstruction employing temporal registration. Magn. Reson. Med.\u00a054, 1207\u20131215 (2005)","journal-title":"Magn. Reson. Med."},{"key":"46_CR12","doi-asserted-by":"publisher","first-page":"939","DOI":"10.1002\/mrm.21222","volume":"57","author":"C. Prieto","year":"2007","unstructured":"Prieto, C., Batchelor, P., Hill, D., Hajnal, J., Guarini, M., Irarrazaval, P.: Reconstruction of undersampled dynamic images by modeling the motion of objects elements. Magn. Reson. Med.\u00a057, 939\u2013949 (2007)","journal-title":"Magn. Reson. Med."},{"key":"46_CR13","doi-asserted-by":"publisher","first-page":"952","DOI":"10.1002\/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO;2-S","volume":"42","author":"K.P. Pruessmann","year":"1999","unstructured":"Pruessmann, K.P., Werger, M., Scheidegger, M.B., Boesinger, P.: SENSE: Sensitivity encoding for fast MRI. Magn. Reson. Med.\u00a042, 952\u2013962 (1999)","journal-title":"Magn. Reson. Med."},{"key":"46_CR14","doi-asserted-by":"publisher","first-page":"591","DOI":"10.1002\/mrm.1910380414","volume":"38","author":"D.K. Sodickson","year":"1997","unstructured":"Sodickson, D.K., Mannin, W.J.: Simultaneous acquisition of spatial harmonics (SMASH): ultra-fast imaging with radiofrequency coil arrays. Magn. Reson. Med.\u00a038, 591\u2013603 (1997)","journal-title":"Magn. Reson. Med."},{"key":"46_CR15","doi-asserted-by":"publisher","first-page":"1273","DOI":"10.1002\/mrm.20656","volume":"54","author":"P.G. Batchelor","year":"2005","unstructured":"Batchelor, P.G., Atkinson, D., Irarrazaval, P., Hill, D.L.G., Hajnal, J., Larkman, D.: Matrix description of genearal motion correction applied to multishot images. Magn. Reson. Med.\u00a054, 1273\u20131280 (2005)","journal-title":"Magn. Reson. Med."},{"key":"46_CR16","doi-asserted-by":"publisher","first-page":"174","DOI":"10.1002\/nbm.755","volume":"15","author":"J.A. d\u2019Arcy","year":"2002","unstructured":"d\u2019Arcy, J.A., Collins, D.J., Rowland, I.J., Padhani, A.R., Leach, M.O.: Applications of sliding window reconstruction with Cartesin sampling for dynamic contrast enhancement MRI. NMR. BioMed.\u00a015, 174\u2013183 (2002)","journal-title":"NMR. BioMed."}],"container-title":["Lecture Notes in Computer Science","Advances in Image and Video Technology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-540-77129-6_46.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,4,27]],"date-time":"2021-04-27T11:02:14Z","timestamp":1619521334000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-540-77129-6_46"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[null]]},"ISBN":["9783540771289"],"references-count":16,"URL":"https:\/\/doi.org\/10.1007\/978-3-540-77129-6_46","relation":{},"subject":[]}}