{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,9,5]],"date-time":"2024-09-05T00:50:45Z","timestamp":1725497445986},"publisher-location":"Berlin, Heidelberg","reference-count":14,"publisher":"Springer Berlin Heidelberg","isbn-type":[{"type":"print","value":"9783540774105"},{"type":"electronic","value":"9783540774136"}],"license":[{"start":{"date-parts":[[2007,1,1]],"date-time":"2007-01-01T00:00:00Z","timestamp":1167609600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2007]]},"DOI":"10.1007\/978-3-540-77413-6_27","type":"book-chapter","created":{"date-parts":[[2007,12,7]],"date-time":"2007-12-07T11:53:16Z","timestamp":1197028396000},"page":"208-215","source":"Crossref","is-referenced-by-count":0,"title":["Using Modified Contour Deformable Model to Quantitatively Estimate Ultrasound Parameters for Osteoporosis Assessment"],"prefix":"10.1007","author":[{"given":"Yung-Fu","family":"Chen","sequence":"first","affiliation":[]},{"given":"Yi-Chun","family":"Du","sequence":"additional","affiliation":[]},{"given":"Yi-Ting","family":"Tsai","sequence":"additional","affiliation":[]},{"given":"Tainsong","family":"Chen","sequence":"additional","affiliation":[]}],"member":"297","reference":[{"key":"27_CR1","doi-asserted-by":"publisher","first-page":"1387","DOI":"10.1088\/0031-9155\/35\/10\/004","volume":"35","author":"J.A. Evans","year":"1990","unstructured":"Evans, J.A., Tavakoli, M.B.: Ultrasonic attenuation and velocity in bone. Phys. Med. Biol.\u00a035, 1387\u20131396 (1990)","journal-title":"Phys. Med. Biol."},{"key":"27_CR2","doi-asserted-by":"publisher","first-page":"963","DOI":"10.1016\/0021-9290(95)00146-8","volume":"29","author":"L. Serpe","year":"1996","unstructured":"Serpe, L., Rho, J.Y.: The nonlinear transition period of broadband ultrasound attenuation as bone density veries. J. Biomechanics\u00a029, 963\u2013966 (1996)","journal-title":"J. Biomechanics"},{"key":"27_CR3","doi-asserted-by":"publisher","first-page":"1337","DOI":"10.1016\/S0301-5629(01)00437-9","volume":"27","author":"C.F. Njeh","year":"2001","unstructured":"Njeh, C.F., Saeed, I., Grigorian, M., Kendler, D.L., Fan, B., Shepherd, J., Mcclung, M., Drake, W.M., Genant, H.K.: Assessment of bone status using speed of sound at multiple anatomical sites. Ultrasound in Med. & Biol.\u00a027, 1337\u20131345 (2001)","journal-title":"Ultrasound in Med. & Biol."},{"key":"27_CR4","doi-asserted-by":"publisher","first-page":"503","DOI":"10.1016\/S8756-3282(02)00843-8","volume":"31","author":"J. Toyras","year":"2002","unstructured":"Toyras, J., Nieminen, M.T., Kroger, H., Jurvelin, J.S.: Bone mineral density, ultrasound velocity, and broadband attenuation predict mechanical predict mechanical properties of trabecular bone differently. Bone\u00a031, 503\u2013507 (2002)","journal-title":"Bone"},{"key":"27_CR5","unstructured":"UBIS 5000 Technical Manual (1999)"},{"key":"27_CR6","doi-asserted-by":"publisher","first-page":"348","DOI":"10.1016\/0268-0033(96)00026-5","volume":"11","author":"S. Han","year":"1996","unstructured":"Han, S., Medige, J., Ziv, I.: Combined models of ultrasound velocity and attenuation for predicting trabecular bone strength and mineral density. Clinical Biomechanics\u00a011, 348\u2013353 (1996)","journal-title":"Clinical Biomechanics"},{"key":"27_CR7","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1016\/S0378-5122(99)00003-1","volume":"31","author":"P. Hadji","year":"1999","unstructured":"Hadji, P., Hars, O., Wuster, C., Bock, K., Alberts, U.S., Bohnet, H.G., Emons, G., Schulz, K.D.: Stiffness index identifies patients with osteoporotic fractures better than ultrasound velocity or attenuation alone. Maturitas\u00a031, 221\u2013226 (1999)","journal-title":"Maturitas"},{"key":"27_CR8","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1109\/42.668693","volume":"17","author":"F. Lefebvre","year":"1998","unstructured":"Lefebvre, F., Berger, G., Laugier, P.: Automatic detection of the calcaneus boundary from ultrasound parametric images using active contour model: Clinical assessment. IEEE. Trans. Med. Imaging\u00a017, 45\u201352 (1998)","journal-title":"IEEE. Trans. Med. Imaging"},{"key":"27_CR9","first-page":"38","volume":"61","author":"T.F. Cootes","year":"1995","unstructured":"Cootes, T.F., Taylor, C.J., Cooper, D.H., Graham, J.: Active shape models- their training and application. CVGIP: Image Understanding\u00a061, 38\u201359 (1995)","journal-title":"CVGIP: Image Understanding"},{"key":"27_CR10","doi-asserted-by":"crossref","unstructured":"Kass, M., Witkin, A., Terzopoulos, D.: Snakes: Active contour models. Int. J. Comput. Vision, 321\u2013331 (1988)","DOI":"10.1007\/BF00133570"},{"key":"27_CR11","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1007\/BF01623454","volume":"7","author":"C.F. Njeh","year":"1997","unstructured":"Njeh, C.F., Boivin, C.M., Langton, C.M.: The Role of Ultrasound in the Assessment of Osteoporosis: A Review. Osteoporosis Int.\u00a07, 7\u201322 (1997)","journal-title":"Osteoporosis Int."},{"key":"27_CR12","doi-asserted-by":"publisher","first-page":"970","DOI":"10.1007\/s001980170027","volume":"12","author":"J.P.W. Bergh van der","year":"2001","unstructured":"van der Bergh, J.P.W., Noordam, C., Thijssen, J.M., Otten, B.J., Smals, A.G.H., Hermus, A.R.M.M.: Measuring skeletal changes with calcaneus ultrasound imaging in healthy children and adults: The influence of size and location of the region of interest. Osteoporos Int.\u00a012, 970\u2013979 (2001)","journal-title":"Osteoporos Int."},{"key":"27_CR13","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1109\/42.370398","volume":"14","author":"S. Lobregt","year":"1995","unstructured":"Lobregt, S., Viergever, M.A.: A discrete dynamic contour model. IEEE. Trans. Med. Imaging\u00a014, 12\u201324 (1995)","journal-title":"IEEE. Trans. Med. Imaging"},{"key":"27_CR14","doi-asserted-by":"publisher","first-page":"363","DOI":"10.1007\/BF01623779","volume":"7","author":"B. Fournier","year":"1997","unstructured":"Fournier, B., Chappard, C., Roux, C., Berger, G., Laugier, P.: Quantitative ultrasound imaging at the calcaneus using an automatic region of interest. Osteoporos Int.\u00a07, 363\u2013369 (1997)","journal-title":"Osteoporos Int."}],"container-title":["Lecture Notes in Computer Science","Medical Biometrics"],"original-title":[],"link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-540-77413-6_27","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,2,26]],"date-time":"2019-02-26T11:08:25Z","timestamp":1551179305000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-540-77413-6_27"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007]]},"ISBN":["9783540774105","9783540774136"],"references-count":14,"URL":"https:\/\/doi.org\/10.1007\/978-3-540-77413-6_27","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"type":"print","value":"0302-9743"},{"type":"electronic","value":"1611-3349"}],"subject":[],"published":{"date-parts":[[2007]]}}}