{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,9,5]],"date-time":"2024-09-05T05:49:36Z","timestamp":1725515376445},"publisher-location":"Berlin, Heidelberg","reference-count":24,"publisher":"Springer Berlin Heidelberg","isbn-type":[{"type":"print","value":"9783540794899"},{"type":"electronic","value":"9783540794905"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"DOI":"10.1007\/978-3-540-79490-5_27","type":"book-chapter","created":{"date-parts":[[2008,6,10]],"date-time":"2008-06-10T03:32:47Z","timestamp":1213068767000},"page":"216-222","source":"Crossref","is-referenced-by-count":3,"title":["Comparison of Chang\u2019s with Sorenson\u2019s Attenuation Correction Method by Varying Linear Attenuation Coefficient Values in Tc-99m SPECT Imaging"],"prefix":"10.1007","author":[{"given":"Inayatullah Shah","family":"Sayed","sequence":"first","affiliation":[]},{"given":"Ahmed","family":"Zakaria","sequence":"additional","affiliation":[]},{"given":"Norhafiza","family":"Nik","sequence":"additional","affiliation":[]}],"member":"297","reference":[{"key":"27_CR1","first-page":"224","volume":"33","author":"M. Hayashi","year":"2005","unstructured":"Hayashi, M., Deguchi, J., Utsunomiya, K., Yamada, M., Komori, T., Takuchi, M., Kana, K., Narabayashi, I.: Comparison of Methods of Attenuation and Scatter Correction in Brain Perfusion SPECT. Journal of Nuclear Medicine Technology\u00a033, 224\u2013229 (2005)","journal-title":"Journal of Nuclear Medicine Technology"},{"key":"27_CR2","first-page":"2026","volume":"45","author":"G. Fakhri El","year":"2004","unstructured":"El Fakhri, G., Kijewski, M.F., Albert, M.S., Johnson, K.A., Moore, S.C.: Quantitative SPECT Leads to Improved Performance in Discrimination Tasks Related to Prodromal Alzheimer\u2019s Disease. J. Nucl. Med.\u00a045, 2026\u20132031 (2004)","journal-title":"J. Nucl. Med."},{"key":"27_CR3","first-page":"512","volume":"44","author":"K.M. Kim","year":"2003","unstructured":"Kim, K.M., Varrone, H., Watabe, H., Shidahara, M., Fujita, M., Innis, R.B., Iida, H.: Contribution of Scatter and Attenuation Compensation to SPECT Images of Nonuniformly Distributed Brain Activities. J. Nucl. Med.\u00a044, 512\u2013519 (2003)","journal-title":"J. Nucl. Med."},{"key":"27_CR4","first-page":"291","volume":"44","author":"H. Zaidi","year":"2003","unstructured":"Zaidi, H., Hasegawa, B.: Determination of the Attenuation Map in Emission Tomography. J. Nucl. Med.\u00a044, 291\u2013315 (2003)","journal-title":"J. Nucl. Med."},{"key":"27_CR5","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1007\/3-540-09417-2_5","volume-title":"Image reconstruction from projections: implementation and applications","author":"T.F. Budinger","year":"1979","unstructured":"Budinger, T.F., Gulberg, G.T., Huesman, R.H.: Emission Computed Tomography. In: Herman, G.T. (ed.) Image reconstruction from projections: implementation and applications, pp. 147\u2013246. Springer, New York (1979)"},{"key":"27_CR6","doi-asserted-by":"publisher","first-page":"799","DOI":"10.1088\/0031-9155\/30\/8\/004","volume":"30","author":"G.T. Gullberg","year":"1985","unstructured":"Gullberg, G.T., Huesman, R.H., Malko, G.A., Plec, N.J., Budinger, T.F.: An attenuated projector-backprojector for iterative SPECT reconstruction. Phy. Med. Bio.\u00a030, 799\u2013816 (1985)","journal-title":"Phy. Med. Bio."},{"key":"27_CR7","first-page":"1489","volume":"36","author":"M.S. Rosenthal","year":"1995","unstructured":"Rosenthal, M.S., Cullom, J., Hawkins, W., Moore, S.C., Tsui, B.M.W., Yester, M.: Quantitative SPECT imaging: A review and recommendations by the Focus Committee of the Society of Nuclear Medicine Computer and Instrumentation Council. J. Nucl. Med.\u00a036, 1489\u20131513 (1995)","journal-title":"J. Nucl. Med."},{"key":"27_CR8","doi-asserted-by":"publisher","first-page":"1489","DOI":"10.1088\/0031-9155\/29\/12\/003","volume":"29","author":"E. Tanaka","year":"1984","unstructured":"Tanaka, E., Toyama, H., Murayama, H.: Convolutional image reconstruction for quantitative single photon emission computed tomography. Phy. Med. Bio.\u00a029, 1489\u20131500 (1984)","journal-title":"Phy. Med. Bio."},{"key":"27_CR9","doi-asserted-by":"publisher","first-page":"663","DOI":"10.1109\/23.289372","volume":"NS-38","author":"S.J. Glick","year":"1991","unstructured":"Glick, S.J., Penney, B.J., King, M.A.: Filtering of SPECT reconstruction made using Bellini\u2019s attenuation correction method: a comparison of three pre-reconstruction and a post reconstruction Wiener filter. IEEE Trans. Nucl. Sci.\u00a0NS-38, 663\u2013669 (1991)","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"27_CR10","doi-asserted-by":"publisher","first-page":"587","DOI":"10.1088\/0031-9155\/37\/3\/007","volume":"37","author":"Z. Liang","year":"1992","unstructured":"Liang, Z., Turkington, T.G., Gilland. Jaszczak, R.J., Coleman, R.E.: Simultaneous compensation for attenuation, scatter, and detector response for SPECT reconstruction in three dimensions. Phys. Med. Bio.\u00a037, 587\u2013603 (1992)","journal-title":"Phys. Med. Bio."},{"key":"27_CR11","first-page":"2232","volume":"33","author":"J.R. Galt","year":"1992","unstructured":"Galt, J.R., Cullom, S.J., Garcia, E.V.: SPECT quantification: a simplified method of attenuation correction method for cardiac imaging. J. Nucl. Med.\u00a033, 2232\u20132237 (1992)","journal-title":"J. Nucl. Med."},{"key":"27_CR12","doi-asserted-by":"publisher","first-page":"1134","DOI":"10.1109\/23.159773","volume":"NS-39","author":"C.H. Tung","year":"1992","unstructured":"Tung, C.H., Gullberg, G.T., Zeng, G.L., Christian, P.E., Datz, F.L., Morgan, H.T.: Nonuniform attenuation correction using simultaneous transmission and emission converging tomography. IEEE Trans. Nucl. Sci.\u00a0NS-39, 1134\u20131143 (1992)","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"27_CR13","first-page":"1204","volume":"34","author":"A. Maze","year":"1993","unstructured":"Maze, A., Le Cloirec, J., Collorec, R., Bizais, Y., Braindet, P., Bourguet, P.: Iterative Reconstruction Methods for Nonuniform Attenuation Distribution in SPECT. J. Nucl. Med.\u00a034, 1204\u20131209 (1993)","journal-title":"J. Nucl. Med."},{"key":"27_CR14","doi-asserted-by":"crossref","first-page":"638","DOI":"10.1109\/TNS.1978.4329385","volume":"NS-35","author":"L.T. Chang","year":"1978","unstructured":"Chang, L.T.: A method for attenuation correction in radionuclide computed tomography. IEEE Trans. Nucl. Sci.\u00a0NS-35, 638\u2013643 (1978)","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"27_CR15","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1097\/00004728-198102000-00016","volume":"1","author":"T.E. Walters","year":"1981","unstructured":"Walters, T.E., Simon, W., Chesler, D.A., Correia, J.A.: Attenuation correction in gamma emission computed tomography. J. Comp. Asst. Tomogr.\u00a01, 89\u201394 (1981)","journal-title":"J. Comp. Asst. Tomogr."},{"key":"27_CR16","first-page":"65","volume":"22","author":"S.C. Moore","year":"1981","unstructured":"Moore, S.C., Brunelle, J.A., Kirsch, C.: An iterative attenuation correction for a single photon scanning multidetector tomography system. J. Nucl. Med.\u00a022, 65 (1981)","journal-title":"J. Nucl. Med."},{"key":"27_CR17","doi-asserted-by":"publisher","first-page":"351","DOI":"10.1007\/BF00449223","volume":"15","author":"J. Mas","year":"1989","unstructured":"Mas, J., Ben Younes, R., Bidet, R.: Improvement of quantification in SPECT studies by scatter and attenuation compensation. Eur. J. Nucl. Med.\u00a015, 351\u2013356 (1989)","journal-title":"Eur. J. Nucl. Med."},{"key":"27_CR18","doi-asserted-by":"publisher","first-page":"1137","DOI":"10.1109\/TNS.1980.4330986","volume":"NS- 27","author":"R.J. Jaszczak","year":"1980","unstructured":"Jaszczak, R.J., Coleman, R.E., Lim, C.B.: Single photon emission computed tomography. IEEE Trans. Nucl. Sci.\u00a0NS- 27, 1137\u20131152 (1980)","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"27_CR19","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1109\/TMI.1984.4307665","volume":"MI-3","author":"T.L. Faber","year":"1984","unstructured":"Faber, T.L., Lewis, M.H., Corbett, J.R., Stokely, E.M.: Attenuation correction for SPECT: An evaluation of Hybrid approaches. IEEE Trans. Medical Imaging\u00a0MI-3, 101\u2013107 (1984)","journal-title":"IEEE Trans. Medical Imaging"},{"key":"27_CR20","first-page":"55","volume":"13","author":"K. Murase","year":"1987","unstructured":"Murase, K., Itoh, H., Mogami, H., Ishine, M., Kawamura, M., Iio, A., Hamamoto, K.: A comparative study of attenuation correction algorithms in single photon emission computed tomography (SPECT). Eur. J. Nucl. Med.\u00a013, 55\u201362 (1987)","journal-title":"Eur. J. Nucl. Med."},{"key":"27_CR21","first-page":"311","volume-title":"Instrumentation in Nuclear Medicine","author":"J.A. Sorenson","year":"1974","unstructured":"Sorenson, J.A.: Methods for quantitative measurement of radioactivity in vivo by whole-body counting. In: Hine, G.J., Sorenson, J.A. (eds.) Instrumentation in Nuclear Medicine, vol.\u00a02, pp. 311\u2013348. Academic Press, New York (1974)"},{"key":"27_CR22","doi-asserted-by":"publisher","first-page":"1087","DOI":"10.1109\/23.256717","volume":"NS-40","author":"T.J. Spinks","year":"1993","unstructured":"Spinks, T.J., Sayed, I.S.: Effect of lead filters on the performance of a Neuro-PET tomography operated without septa. IEEE Trans. Nucl. Sci.\u00a0NS-40, 1087\u20131091 (1993)","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"27_CR23","unstructured":"Sayed, I.S.: Reduction of Scattered gammas and Attenuation Correction in SPET. Ph D Thesis, King\u2019s College London, University of London (1996)"},{"key":"27_CR24","doi-asserted-by":"publisher","first-page":"38","DOI":"10.1016\/S0001-2998(05)80248-X","volume":"24","author":"B.M.W. Tsui","year":"1994","unstructured":"Tsui, B.M.W., Zhao, X., Frey, E.C., McCartney, W.H.: Quantitative single photon emission computed tomography: basics and clinical considerations. Seminars in Nucl. Med.\u00a024, 38\u201365 (1994)","journal-title":"Seminars in Nucl. Med."}],"container-title":["Lecture Notes in Computer Science","Medical Imaging and Informatics"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-540-79490-5_27.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,4,27]],"date-time":"2021-04-27T07:23:31Z","timestamp":1619508211000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-540-79490-5_27"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[null]]},"ISBN":["9783540794899","9783540794905"],"references-count":24,"URL":"https:\/\/doi.org\/10.1007\/978-3-540-79490-5_27","relation":{},"subject":[]}}