{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,9,5]],"date-time":"2024-09-05T05:51:56Z","timestamp":1725515516781},"publisher-location":"Berlin, Heidelberg","reference-count":10,"publisher":"Springer Berlin Heidelberg","isbn-type":[{"type":"print","value":"9783540799818"},{"type":"electronic","value":"9783540799825"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"DOI":"10.1007\/978-3-540-79982-5_29","type":"book-chapter","created":{"date-parts":[[2008,7,14]],"date-time":"2008-07-14T15:28:29Z","timestamp":1216049309000},"page":"260-269","source":"Crossref","is-referenced-by-count":0,"title":["Surgical Manipulator with Balloon for Stabilizing Fetus in Utero under Ultrasound Guidance"],"prefix":"10.1007","author":[{"given":"Noriaki","family":"Yamanaka","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiromasa","family":"Yamashita","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kiyoshi","family":"Matsumiya","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hongen","family":"Liao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ken","family":"Masamune","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Toshio","family":"Chiba","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takeyoshi","family":"Dohi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"29_CR1","doi-asserted-by":"publisher","first-page":"312","DOI":"10.1159\/000053934","volume":"16","author":"D.S. Walsh","year":"2001","unstructured":"Walsh, D.S., Adzick, N.S., Sutton, L.N., Johnson, M.P.: The Rationale for in utero Repair of Myelomeningocele. Fetal. Diagn. Ther.\u00a016, 312\u2013322 (2001)","journal-title":"Fetal. Diagn. Ther."},{"key":"29_CR2","doi-asserted-by":"publisher","first-page":"872","DOI":"10.1001\/archsurg.138.8.872","volume":"138","author":"D.L. Farmer","year":"2003","unstructured":"Farmer, D.L., Koch, C.S., Peacock, W.J., Danielpour, M., Gupta, N., Lee, H., Harrison, M.R.: In Utero Repair of Myelomeningocele. Arch. Surg.\u00a0138, 872\u2013878 (2003)","journal-title":"Arch. Surg."},{"key":"29_CR3","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1016\/S0002-9378(99)70167-5","volume":"180","author":"J.P. Bruner","year":"1999","unstructured":"Bruner, J.P., Richards, W.O., Tulipan, N.B., Arney, T.L.: Endoscopic coverage of fetal myelomeningocele in utero. Am. J. Obstet. Gynccol.\u00a0180, 153\u2013158 (1999)","journal-title":"Am. J. Obstet. Gynccol."},{"key":"29_CR4","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1159\/000089301","volume":"21","author":"T. Kohl","year":"2006","unstructured":"Kohl, T., Hering, R., Heep, A., Schaller, C., Meyer, B., Greive, C., et al.: Percutaneous Fetoscopic Patch Coverage of Spina Bifida Aperta in the Human - Early Clinical Experience and Potential. Fetal Diagn Ther.\u00a021, 185\u2013193 (2006)","journal-title":"Fetal Diagn Ther."},{"key":"29_CR5","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1159\/000074267","volume":"19","author":"A.H. Hamada","year":"2004","unstructured":"Hamada, A.H., Walsh, W., Heddings, A., Bruner, J.P., Tulipan, N.: Intrauterine myelomeningocele Repair: effect on Short-Term Complications of Prematurity. Fetal Diagn Ther.\u00a019, 83\u201386 (2004)","journal-title":"Fetal Diagn Ther."},{"key":"29_CR6","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1159\/000089060","volume":"2","author":"R. Barini","year":"2006","unstructured":"Barini, R., Weber, M., Barreto, G., Cursino, K., Zambelli, H., Parando, A., Sbragia, L.: Abruptio Placentae during Fetal Myelomeningocele Repair. Fetal Diagn Ther.\u00a02, 115\u2013117 (2006)","journal-title":"Fetal Diagn Ther."},{"key":"29_CR7","doi-asserted-by":"publisher","first-page":"420","DOI":"10.1007\/s004649901004","volume":"13","author":"K.C. Oberg","year":"1999","unstructured":"Oberg, K.C., Robles, A.E., Ducsay, C.A., Rasi, C.R., Rouse, G.A., Childers, B.J., Evans, M.L., Kirsch, W.M., Hardesty, R.A.: Endoscopic intrauterine surgery in primates. Surg. Endosc.\u00a013, 420\u2013426 (1999)","journal-title":"Surg. Endosc."},{"key":"29_CR8","unstructured":"Tsubouchi, K., Harada, K., Chiba, T., Enosawa, S., Fujie, M.G.: Development of the drawn-in type stabilizer for a fetus operation. In: The 14th conference of Japan computer-aided-surgery society, pp. 45\u201346 (2005)"},{"key":"29_CR9","series-title":"Lecture Notes in Computer Science","doi-asserted-by":"publisher","first-page":"412","DOI":"10.1007\/11866565_51","volume-title":"Medical Image Computing and Computer-Assisted Intervention \u2013 MICCAI 2006","author":"H. Liao","year":"2006","unstructured":"Liao, H., Suzuki, H., Matsumiya, K., Masamune, K., Dohi, T., Chiba, T.: Fetus Support Manipulator with Flexible Balloon-Based Stabilizer for Endoscopic Intrauterine Surgery. In: Larsen, R., Nielsen, M., Sporring, J. (eds.) MICCAI 2006. LNCS, vol.\u00a04190, pp. 412\u2013419. Springer, Heidelberg (2006)"},{"key":"29_CR10","doi-asserted-by":"crossref","unstructured":"Yamanaka, N., Yamashita, H., Matsumiya, K., Liao, H., Masamune, K., Chiba, T., Dohi, T.: Balloon-Based Manipulator with Multiple Linkages for Intrauterine Surgery. In: Proceedings of the 2007 IEEE\/RSJ International Conference on Intelligent Robots and Systems, pp. 1278\u20131283 (2007)","DOI":"10.1109\/IROS.2007.4399620"}],"container-title":["Lecture Notes in Computer Science","Medical Imaging and Augmented Reality"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-540-79982-5_29.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,4,27]],"date-time":"2021-04-27T07:35:50Z","timestamp":1619508950000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-540-79982-5_29"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[null]]},"ISBN":["9783540799818","9783540799825"],"references-count":10,"URL":"https:\/\/doi.org\/10.1007\/978-3-540-79982-5_29","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"type":"print","value":"0302-9743"},{"type":"electronic","value":"1611-3349"}],"subject":[]}}