{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,11]],"date-time":"2026-11-11T00:54:07Z","timestamp":1794358447832,"version":"4.9.0"},"publisher-location":"Berlin, Heidelberg","reference-count":13,"publisher":"Springer Berlin Heidelberg","isbn-type":[{"value":"9783540859871","type":"print"},{"value":"9783540859888","type":"electronic"}],"license":[{"start":{"date-parts":[[2008,1,1]],"date-time":"2008-01-01T00:00:00Z","timestamp":1199145600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2008,1,1]],"date-time":"2008-01-01T00:00:00Z","timestamp":1199145600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2008]]},"DOI":"10.1007\/978-3-540-85988-8_35","type":"book-chapter","created":{"date-parts":[[2008,9,9]],"date-time":"2008-09-09T02:50:22Z","timestamp":1220928622000},"page":"287-295","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":27,"title":["Bone Segmentation and Fracture Detection in Ultrasound Using 3D Local Phase Features"],"prefix":"10.1007","author":[{"given":"Ilker","family":"Hacihaliloglu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rafeef","family":"Abugharbieh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antony","family":"Hodgson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert","family":"Rohling","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","reference":[{"issue":"1","key":"35_CR1","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1016\/S0030-5898(03)00071-3","volume":"33","author":"D.P. Hanel","year":"2002","unstructured":"Hanel, D.P., Jones, M.D., Trumble, T.E.: Wrist fractures. Orthop. Clin. North. Am.\u00a033(1), 35\u201357 (2002)","journal-title":"Orthop. Clin. North. Am."},{"issue":"1","key":"35_CR2","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/S0733-8627(05)70106-1","volume":"18","author":"P.T. Coppola","year":"2000","unstructured":"Coppola, P.T., Coppola, M.: Emergency department evaluation and treatment of pelvic fractures. Emergency Medicine Clinics of North America\u00a018(1), 1\u201327 (2000)","journal-title":"Emergency Medicine Clinics of North America"},{"key":"35_CR3","doi-asserted-by":"crossref","unstructured":"Jain, A.K., Taylor, R.H.: Understanding bone responses in B-mode ultrasound images and automatic bone surface extraction using a bayesian probabilistic framework. In: Proc. of SPIE Medical Imaging, pp. 131\u2013142 (2004)","DOI":"10.1117\/12.535984"},{"key":"35_CR4","doi-asserted-by":"publisher","first-page":"312","DOI":"10.1109\/TMI.2005.862736","volume":"25","author":"D.C. Barratt","year":"2006","unstructured":"Barratt, D.C., Penney, P.G., Chan, S.K., Slomczykowski, M., Carter, T.J., Edwards, P.J., Hawkes, D.J.: Self calibrating 3D-ultrasound-based bone registration for minimally invasive orthopaedic surgery. IEEE Transactions on Medical Imaging\u00a025, 312\u2013323 (2006)","journal-title":"IEEE Transactions on Medical Imaging"},{"key":"35_CR5","doi-asserted-by":"crossref","unstructured":"Kowal, J., Amstutz, C., Langlotz, F., Talib, H., Ballester, M.G.: Automated bone contour detection in ultrasound B-mode images for minimally invasive registration in computer assisted surgery an in vitro evaluation. The International Journal of Medical Robotics and Computer Assisted Surgery, 341\u2013348 (2007)","DOI":"10.1002\/rcs.160"},{"key":"35_CR6","series-title":"Lecture Notes in Computer Science","doi-asserted-by":"publisher","first-page":"549","DOI":"10.1007\/978-3-540-30135-6_67","volume-title":"Medical Image Computing and Computer-Assisted Intervention \u2013 MICCAI 2004","author":"V. Daanen","year":"2004","unstructured":"Daanen, V., Tonetti, J., Troccaz, J.: A fully automated method for the delineation of osseous interface in ultrasound images. In: Barillot, C., Haynor, D.R., Hellier, P. (eds.) MICCAI 2004. LNCS, vol.\u00a03216, pp. 549\u2013557. Springer, Heidelberg (2004)"},{"key":"35_CR7","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3109\/10929080309146097","volume":"8","author":"D.V. Amin","year":"2003","unstructured":"Amin, D.V., Kanade, T., Digioia, A.M., Jaramaz, B.: Ultrasound registration of the bone surface for surgical navigation. Journal of Computer Aided Surgery\u00a08, 1\u201316 (2003)","journal-title":"Journal of Computer Aided Surgery"},{"issue":"1","key":"35_CR8","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1016\/S1361-8415(00)00006-2","volume":"4","author":"M. Mulet-Parada","year":"2000","unstructured":"Mulet-Parada, M., Noble, J.A.: 2D+T boundary detection in echocardiography. Medical Image Analysis\u00a04(1), 21\u201330 (2000)","journal-title":"Medical Image Analysis"},{"key":"35_CR9","doi-asserted-by":"crossref","unstructured":"Hacihaliloglu, I., Abugharbieh, R., Hodgson, A.J., Rohling, R.N.: Enhancement of bone surface visualization from 3D ultrasound based on local phase information. In: Proc. IEEE Ultrasonics Symposium, pp. 21\u201324 (2006)","DOI":"10.1109\/ULTSYM.2006.20"},{"key":"35_CR10","unstructured":"Kovesi, P.: Symmetry and Asymmetry from Local Phase, AI 1997. In: Tenth Australian Joint Conference on Artificial Intellegence, pp. 185\u2013190 (1997)"},{"key":"35_CR11","doi-asserted-by":"crossref","unstructured":"Dosil, R., Pardo, X.M., Fernandez-Vidal, X.R.: Data driven synthesis of composite feature detectors for 3D image analysis. Journal of Image and Vision Computing, 225\u2013238 (2006)","DOI":"10.1016\/j.imavis.2005.11.005"},{"key":"35_CR12","unstructured":"Kovesi, P.: Image Features From Phase Congruency. Videre: A Journal of Computer Vision Research (1999)"},{"key":"35_CR13","doi-asserted-by":"crossref","unstructured":"Phillips, R.: The accuracy of surgical navigation for othopaedic surgery. Current Orthopaedics, 180\u2013192 (2007)","DOI":"10.1016\/j.cuor.2007.06.006"}],"container-title":["Lecture Notes in Computer Science","Medical Image Computing and Computer-Assisted Intervention \u2013 MICCAI 2008"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-540-85988-8_35","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,9]],"date-time":"2024-05-09T02:56:49Z","timestamp":1715223409000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/978-3-540-85988-8_35"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008]]},"ISBN":["9783540859871","9783540859888"],"references-count":13,"URL":"https:\/\/doi.org\/10.1007\/978-3-540-85988-8_35","relation":{"is-part-of":[{"id-type":"doi","id":"https:\/\/doi.org\/10.1007\/978-3-540-85988-8","asserted-by":"object"}]},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"value":"0302-9743","type":"print"},{"value":"1611-3349","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008]]},"assertion":[{"value":"This content has been made available to all.","name":"free","label":"Free to read"}]}}