{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,12]],"date-time":"2026-04-12T03:55:33Z","timestamp":1775966133659,"version":"3.50.1"},"publisher-location":"Berlin, Heidelberg","reference-count":13,"publisher":"Springer Berlin Heidelberg","isbn-type":[{"value":"9783540859895","type":"print"},{"value":"9783540859901","type":"electronic"}],"license":[{"start":{"date-parts":[[2008,1,1]],"date-time":"2008-01-01T00:00:00Z","timestamp":1199145600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2008,1,1]],"date-time":"2008-01-01T00:00:00Z","timestamp":1199145600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2008]]},"DOI":"10.1007\/978-3-540-85990-1_19","type":"book-chapter","created":{"date-parts":[[2008,10,29]],"date-time":"2008-10-29T13:37:47Z","timestamp":1225287467000},"page":"155-162","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Motion Correction in Respiratory Gated Cardiac PET\/CT Using Multi-scale Optical Flow"],"prefix":"10.1007","author":[{"given":"Mohammad","family":"Dawood","sequence":"first","affiliation":[]},{"given":"Thomas","family":"K\u00f6sters","sequence":"additional","affiliation":[]},{"given":"Michael","family":"Fieseler","sequence":"additional","affiliation":[]},{"given":"Florian","family":"B\u00fcther","sequence":"additional","affiliation":[]},{"given":"Xiaoyi","family":"Jiang","sequence":"additional","affiliation":[]},{"given":"Frank","family":"W\u00fcbbeling","sequence":"additional","affiliation":[]},{"given":"Klaus P.","family":"Sch\u00e4fers","sequence":"additional","affiliation":[]}],"member":"297","reference":[{"issue":"8","key":"19_CR1","first-page":"1287","volume":"45","author":"Y.. Erdi","year":"2004","unstructured":"Erdi, Y., Nehmeh, S., Pan, T., Pevsner, A., Rosenzweig, K., Mageras, G., Yorke, E.D., Schoder, H., Hsiao, W., Squire, O.D., Vernon, P., Ashman, J.B., Mostafavi, H., Larson, S.M., Humm, J.L.: The CT motion quantitation of lung lesions and its impact on PET-measured SUVs. J. Nucl. Med.\u00a045(8), 1287\u20131292 (2004)","journal-title":"J. Nucl. Med."},{"issue":"2","key":"19_CR2","first-page":"240","volume":"44","author":"M.. Osman","year":"2003","unstructured":"Osman, M.M., Cohade, C., Nakamoto, Y., Marshall, L., Leal, J., Wahl, R.: Clinically significant inaccurate localization of lesions with PET\/CT: frequency in 300 patients. J. Nucl. Med.\u00a044(2), 240\u2013243 (2003)","journal-title":"J. Nucl. Med."},{"issue":"3","key":"19_CR3","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1097\/00006231-200403000-00002","volume":"25","author":"Y. Nakamoto","year":"2004","unstructured":"Nakamoto, Y., Chin, B., Cohade, C., Osman, M., Tatsumi, M., Wahl, R.: PET\/CT: artifacts caused by bowel motion. Nucl. Med. Commun.\u00a025(3), 221\u2013225 (2004)","journal-title":"Nucl. Med. Commun."},{"key":"19_CR4","doi-asserted-by":"crossref","unstructured":"Dawood, M., B\u00fcther, F., Jiang, X., Sch\u00e4fers, K.P.: Respiratory Motion Correction in 3D PET Data with Advanced Optical Flow Algorithms. In: IEEE Trans. Med. Imaging (in press, 2008)","DOI":"10.1109\/TMI.2008.918321"},{"key":"19_CR5","doi-asserted-by":"publisher","first-page":"3067","DOI":"10.1118\/1.2748104","volume":"34","author":"M. Dawood","year":"2007","unstructured":"Dawood, M., B\u00fcther, F., Lang, N., Schober, O., Sch\u00e4fers, K.P.: Respiratory gating in positron emission tomography: A quantitative comparision of different gating schemes. Medical Physics\u00a034, 3067\u20133076 (2007)","journal-title":"Medical Physics"},{"issue":"4","key":"19_CR6","doi-asserted-by":"publisher","first-page":"476","DOI":"10.1109\/TMI.2006.870892","volume":"25","author":"M. Dawood","year":"2006","unstructured":"Dawood, M., Lang, N., Jiang, X., Sch\u00e4fers, K.P.: Lung motion correction on respiratory gated 3-D PET\/CT images. IEEE Trans. Med. Imaging\u00a025(4), 476\u2013485 (2006)","journal-title":"IEEE Trans. Med. Imaging"},{"issue":"15","key":"19_CR7","doi-asserted-by":"publisher","first-page":"3769","DOI":"10.1088\/0031-9155\/51\/15\/012","volume":"51","author":"F. Qiao","year":"2006","unstructured":"Qiao, F., Pan, T., Clark, J.W., Mawlawi, O.R.: A motion-incorporated reconstruction method for gated PET studies. Phys. Med. Biol.\u00a051(15), 3769\u20133783 (2006)","journal-title":"Phys. Med. Biol."},{"issue":"9","key":"19_CR8","doi-asserted-by":"publisher","first-page":"1130","DOI":"10.1109\/TMI.2006.879323","volume":"25","author":"B.A. Mair","year":"2006","unstructured":"Mair, B.A., Gilland, D.R., Sun, J.: Estimation of images and nonrigid deformations in gated emission CT. IEEE Trans. Med. Imaging\u00a025(9), 1130\u20131144 (2006)","journal-title":"IEEE Trans. Med. Imaging"},{"key":"19_CR9","doi-asserted-by":"publisher","first-page":"5187","DOI":"10.1088\/0031-9155\/52\/17\/006","volume":"52","author":"F. Lamare","year":"2007","unstructured":"Lamare, F., Carbayo, M., Cresson, T., Kontaxakis, G., Santos, A., Rest, C., Reader, A., Visvikis, D.: List-mode-based reconstruction for respiratory motion correction in PET using non-rigid body transformations. Phys. Med. Biol.\u00a052, 5187\u20135204 (2007)","journal-title":"Phys. Med. Biol."},{"issue":"4","key":"19_CR10","doi-asserted-by":"publisher","first-page":"603","DOI":"10.1007\/s00259-002-1024-x","volume":"30","author":"M.M. Osman","year":"2003","unstructured":"Osman, M.M., Cohade, C., Nakamoto, Y., Wahl, R.L.: Respiratory motion artifacts on pet emission images obtained using CT attenuation correction on PET-CT. Eur. J. Nucl. Med. Mol. Imaging\u00a030(4), 603\u2013606 (2003)","journal-title":"Eur. J. Nucl. Med. Mol. Imaging"},{"issue":"2","key":"19_CR11","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1016\/S0895-6111(00)00060-4","volume":"25","author":"S. Vandenberghe","year":"2001","unstructured":"Vandenberghe, S., D\u2019Asseler, Y., Van de Walle, R., Kauppinen, T., Koole, M., Bouwens, L., Van Laere, K., Lemahieu, I., Dierckx, R.A.: Iterative reconstruction algorithms in nuclear medicine. Comput. Med. Imaging Graph\u00a025(2), 105\u2013111 (2001)","journal-title":"Comput. Med. Imaging Graph"},{"issue":"3","key":"19_CR12","doi-asserted-by":"publisher","first-page":"211","DOI":"10.1023\/B:VISI.0000045324.43199.43","volume":"61","author":"A. Bruhn","year":"2005","unstructured":"Bruhn, A., Weickert, J., Schn\u00f6rr, C.: Lucas\/Kanade meets Horn\/Schunck: Combining local and global optic flow methods. International Journal of Computer Vision\u00a061(3), 211\u2013231 (2005)","journal-title":"International Journal of Computer Vision"},{"issue":"5","key":"19_CR13","first-page":"813","volume":"45","author":"Y.E. Erdi","year":"2004","unstructured":"Erdi, Y.E., Nehmeh, S.A., Mulnix, T., Humm, J.L., Watson, C.C.: PET performance measurements for an LSO-based combined PET\/CT scanner using the national electrical manufacturers association nu 2-2001 standard. J. Nucl. Med.\u00a045(5), 813\u2013821 (2004)","journal-title":"J. Nucl. Med."}],"container-title":["Lecture Notes in Computer Science","Medical Image Computing and Computer-Assisted Intervention \u2013 MICCAI 2008"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-540-85990-1_19","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,4]],"date-time":"2024-05-04T04:10:21Z","timestamp":1714795821000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/978-3-540-85990-1_19"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008]]},"ISBN":["9783540859895","9783540859901"],"references-count":13,"URL":"https:\/\/doi.org\/10.1007\/978-3-540-85990-1_19","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"value":"0302-9743","type":"print"},{"value":"1611-3349","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008]]},"assertion":[{"value":"This content has been made available to all.","name":"free","label":"Free to read"}]}}