{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,3,27]],"date-time":"2025-03-27T13:24:26Z","timestamp":1743081866585,"version":"3.40.3"},"publisher-location":"Berlin, Heidelberg","reference-count":26,"publisher":"Springer Berlin Heidelberg","isbn-type":[{"type":"print","value":"9783642140747"},{"type":"electronic","value":"9783642140754"}],"license":[{"start":{"date-parts":[[2010,1,1]],"date-time":"2010-01-01T00:00:00Z","timestamp":1262304000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2010]]},"DOI":"10.1007\/978-3-642-14075-4_30","type":"book-chapter","created":{"date-parts":[[2010,7,2]],"date-time":"2010-07-02T14:00:42Z","timestamp":1278079242000},"page":"211-218","source":"Crossref","is-referenced-by-count":10,"title":["Development of a 3\u00a0DoF MR-Compatible Haptic Interface for Pointing and Reaching Movements"],"prefix":"10.1007","author":[{"given":"Stefan","family":"Klare","sequence":"first","affiliation":[]},{"given":"Angelika","family":"Peer","sequence":"additional","affiliation":[]},{"given":"Martin","family":"Buss","sequence":"additional","affiliation":[]}],"member":"297","reference":[{"key":"30_CR1","unstructured":"ASTM, Standard test method for measurement of magnetically induced displacement force on medical devices in the magnetic resonance environment (2002), http:\/\/www.astm.org"},{"key":"30_CR2","doi-asserted-by":"crossref","unstructured":"Flueckinger, M., Bullo, M., Chapuis, D., Gassert, R., Perriard, Y.: fMRI compatible haptic interface actuated with traveling wave ultrasonic motor. In: Industry Applications Conference, vol.\u00a03, pp. 2075\u20132082 (2005)","DOI":"10.1109\/IAS.2005.1518734"},{"key":"30_CR3","doi-asserted-by":"crossref","unstructured":"Riener, R., Villgrattner, T., Kleiser, R., Nef, T., Kollias, S.: fMRI-compatible electromagnetic haptic interface. In: 27th Annual International Conference of the Engineering in Medicine and Biology Society, pp. 7024\u20137027 (2005)","DOI":"10.1109\/IEMBS.2005.1616123"},{"key":"30_CR4","doi-asserted-by":"crossref","unstructured":"Gassert, R., Dovat, L., Lambercy, O., Ruffieux, Y., Chapuis, D., Ganesh, G., Burdet, E., Bleuler, H.: A 2-DoF fMRI compatible haptic interface to investigate the neural control of arm movements. In: IEEE International Conference on Robotics and Automation, pp. 3825\u20133831 (2006)","DOI":"10.1109\/ROBOT.2006.1642287"},{"key":"30_CR5","doi-asserted-by":"crossref","unstructured":"Yu, N., Hollnagel, C., Blickenstorfer, A., Kollias, S., Riener, R.: fMRI-compatible robotic interfaces with fluidic actuation. In: Proceedings of Robotics: Science and Systems IV, Zurich, Switzerland (June 2008)","DOI":"10.15607\/RSS.2008.IV.026"},{"issue":"2","key":"30_CR6","doi-asserted-by":"publisher","first-page":"216","DOI":"10.1109\/TMECH.2006.871897","volume":"11","author":"R. Gassert","year":"2006","unstructured":"Gassert, R., Moser, R., Burdet, E., Bleuler, H.: MRI\/fMRI-compatible robotic system with force feedback for interaction with human motion. IEEE\/ASME Transactions on Mechatronics\u00a011(2), 216\u2013224 (2006)","journal-title":"IEEE\/ASME Transactions on Mechatronics"},{"key":"30_CR7","doi-asserted-by":"crossref","unstructured":"Izawa, J., Shimizu, T., Gomi, H., Toyama, S., Ito, K.: MR compatible manipulandum with ultrasonic motor for fMRI studies. In: IEEE International Conference on Robotics and Automation, pp. 3850\u20133854 (2006)","DOI":"10.1109\/ROBOT.2006.1642291"},{"key":"30_CR8","doi-asserted-by":"crossref","unstructured":"Hara, M., Matthey, G., Yamamoto, A., Chapuis, D., Gassert, R., Bleuler, H., Higuchi, T.: Development of a 2-dof electrostatic haptic joystick for MRI\/fMRI applications. In: IEEE International Conference on Robotics and Automation, pp. 1479\u20131484 (2009)","DOI":"10.1109\/ROBOT.2009.5152850"},{"key":"30_CR9","doi-asserted-by":"publisher","first-page":"9919","DOI":"10.1523\/JNEUROSCI.1874-05.2005","volume":"25","author":"J. Dietrichsen","year":"2005","unstructured":"Dietrichsen, J., Hashambhoy, Y., Rane, T., Shadmehr, R.: Neural correlates of reach errors. The Journal of Neuroscience\u00a025, 9919\u20139931 (2005)","journal-title":"The Journal of Neuroscience"},{"key":"30_CR10","doi-asserted-by":"publisher","first-page":"535","DOI":"10.1109\/WHC.2009.4810837","volume-title":"Proceedings of the World Haptics 2009-Third Joint EuroHaptics Conference and Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems","author":"S. Li","year":"2009","unstructured":"Li, S., Frisoli, A., Borelli, L., Bergamasco, M., Raabe, M., Greenlee, M.: Design of a new fMRI compatible haptic interface. In: Proceedings of the World Haptics 2009-Third Joint EuroHaptics Conference and Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems, pp. 535\u2013540. IEEE Computer Society, Washington (2009)"},{"key":"30_CR11","unstructured":"Sutter, P., Iatridis, J., Thakor, N.: Response to Reflected-Force Feedback to Fingers in Teleoperations. In: Proc. of the NASA Conference on Space Telerobotics,"},{"key":"30_CR12","unstructured":"Wiker, S., Hershkowitz, E., Zik, J.: Teleoperator comfort and psychometric stability: Criteria for limiting master-controller forces of operation and feedback during telemanipulation. In: JPL, California Inst. of Tech., Proceedings of the NASA Conference on Space Telerobotics, vol.\u00a01 (1989)"},{"key":"30_CR13","doi-asserted-by":"crossref","unstructured":"Brooks, T., Robotics, S., Lanham, M.: Telerobotic response requirements. In: IEEE International Conference on Systems, Man and Cybernetics, pp. 113\u2013120 (1990)","DOI":"10.1109\/ICSMC.1990.142071"},{"issue":"13","key":"30_CR14","doi-asserted-by":"publisher","first-page":"1386","DOI":"10.1080\/00140130410001724255","volume":"47","author":"K. Abdel-Malek","year":"2004","unstructured":"Abdel-Malek, K., Yang, J., Brand, R., Tanbour, E.: Towards understanding the workspace of human limbs. Ergonomics\u00a047(13), 1386\u20131405 (2004)","journal-title":"Ergonomics"},{"key":"30_CR15","unstructured":"Nakagawara, S., Kajimoto, H., Kawakami, N., Tachi, S., Kawabuchi, I.: An encounter-type multi-fingered master hand using circuitous joints. In: IEEE International Conference on Robotics and Automation, vol.\u00a03, p. 2667. IEEE, Los Alamitos (1999\/2005)"},{"key":"30_CR16","doi-asserted-by":"crossref","first-page":"1685","DOI":"10.1152\/jn.2001.86.4.1685","volume":"86","author":"M. Gentilucci","year":"2001","unstructured":"Gentilucci, M., Benuzzi, F., Gangitano, M., Grimaldi, S.: Grasp with hand and mouth: A kinematic study on healthy subjects. Journal of Neurophysiology\u00a086, 1685 (2001)","journal-title":"Journal of Neurophysiology"},{"key":"30_CR17","doi-asserted-by":"crossref","unstructured":"Fischer, P., Daniel, R., Siva, K.: Specification and design of input devices for teleoperation. In: IEEE International Conference on Robotics and Automation, pp. 540\u2013545 (1990)","DOI":"10.1109\/ROBOT.1990.126036"},{"key":"30_CR18","doi-asserted-by":"crossref","unstructured":"McAffee, D., Fiorini, P.: Hand controller design requirements and performance issues in telerobotics. In: Fifth International Conference on Advanced Robotics, Robots in Unstructured Environments, pp. 186\u2013192 (1991)","DOI":"10.1109\/ICAR.1991.240655"},{"key":"30_CR19","doi-asserted-by":"crossref","unstructured":"Hayward, V., Astley, O.: Performance measures for haptic interfaces. In: Robotics Research-International Symposium, Citeseer, vol.\u00a07, pp. 195\u2013206 (1996)","DOI":"10.1007\/978-1-4471-1021-7_22"},{"key":"30_CR20","unstructured":"Clavel, R.: Conception d\u2019un robot parallele rapide a 4 degres de liberte. PhD thesis, Ecole Polytechnique Federal de Lausanne (1991)"},{"key":"30_CR21","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1109\/EMB.2007.910268","volume":"739","author":"K. Uffmann","year":"2008","unstructured":"Uffmann, K., Ladd, M.: Actuation Systems for MR Elastography. IEEE Engineering in medicine and biology magazine\u00a0739, 28\u201334 (2008)","journal-title":"IEEE Engineering in medicine and biology magazine"},{"key":"30_CR22","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1109\/EMB.2007.910260","volume":"739","author":"H. Elhawary","year":"2008","unstructured":"Elhawary, H., Zivanovic, A., Rea, M., Davies, B., Besant, C., Young, I., Lamperth, M.: A modular approach to MRI-compatible robotics. IEEE Engineering in medicine and biology magazine\u00a0739, 35\u201341 (2008)","journal-title":"IEEE Engineering in medicine and biology magazine"},{"key":"30_CR23","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1109\/EMB.2007.910265","volume":"27","author":"R. Gassert","year":"2008","unstructured":"Gassert, R., Burdet, E., Chinzei, K.: Opportunities and challenges in MR-compatible robotics. IEEE Engineering in medicine and biology magazine\u00a027, 15\u201322 (2008)","journal-title":"IEEE Engineering in medicine and biology magazine"},{"key":"30_CR24","series-title":"Lecture Notes in Computer Science","doi-asserted-by":"publisher","first-page":"1020","DOI":"10.1007\/10704282_111","volume-title":"Medical Image Computing and Computer-Assisted Intervention \u2013 MICCAI\u201999","author":"K. Chinzei","year":"1999","unstructured":"Chinzei, K., Kikinis, R., Jolesz, F.: MR compatibility of mechatronic devices: design criteria. In: Taylor, C., Colchester, A. (eds.) MICCAI 1999. LNCS, vol.\u00a01679, pp. 1020\u20131030. Springer, Heidelberg (1999)"},{"issue":"12","key":"30_CR25","doi-asserted-by":"publisher","first-page":"1325","DOI":"10.1177\/027836499801701205","volume":"17","author":"A. Codourey","year":"1998","unstructured":"Codourey, A.: Dynamic modeling of parallel robots for computed-torque control implementation. The International Journal of Robotics Research\u00a017(12), 1325 (1998)","journal-title":"The International Journal of Robotics Research"},{"key":"30_CR26","doi-asserted-by":"publisher","DOI":"10.1007\/3-540-29939-4","volume-title":"Parallelkinematische Maschinen","author":"R. Neugebauer","year":"2006","unstructured":"Neugebauer, R.: Parallelkinematische Maschinen. Springer, Heidelberg (2006) (in German)"}],"container-title":["Lecture Notes in Computer Science","Haptics: Generating and Perceiving Tangible Sensations"],"original-title":[],"link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-642-14075-4_30","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,2,22]],"date-time":"2025-02-22T14:22:25Z","timestamp":1740234145000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-642-14075-4_30"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010]]},"ISBN":["9783642140747","9783642140754"],"references-count":26,"URL":"https:\/\/doi.org\/10.1007\/978-3-642-14075-4_30","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"type":"print","value":"0302-9743"},{"type":"electronic","value":"1611-3349"}],"subject":[],"published":{"date-parts":[[2010]]}}}